![MAGNATECH Pipeliner II 609A Operating And Maintenance Instruction Manual Download Page 45](http://html1.mh-extra.com/html/magnatech/pipeliner-ii-609a/pipeliner-ii-609a_operating-and-maintenance-instruction-manual_3554107045.webp)
42
PIPELINER WELD LOG SHEET
DATE:____________________
Pipe Size:___________” O.D. (__________mm) x ________” (_______mm) Wall Thickness
Pipe Material:________________________________________________________________________
PQR No.:________________________________
Company Developed For:______________________________________________________________
Program Developed By:_______________________________________________________________
Weld Position:____________ Weld Progression (Double-Up or Double-Down):____________
Joint Geometry:______________________________________________________________________
Filler Material:_________________________________________ Wire Diameter:_______________
System Model/Power Source Used:____________________________________________________
Gas Nozzle Orifice:___________________________________________________________________
Contact Tip Size: Flush/Extended______________________________________________________
Contact Tip Size: Std./Tapered________________________________________________________
Stickout:_____________________________________________________________________________
Amperage Range Used:_______________________________________________________________
Voltage Range Used:_________________________________________________________________
(Lead or Lag Angle):______________
Shield Gas Composition:______________________________________________________________
Backing or Root Pass Method:_________________________________________________________
Preheat Required:____________________________________________________________________
Interpass Temp Limitations:___________________________________________________________
Heat Input Limitations:________________________________________________________________
Total Passes:________________________________________________________________________
Total Arc Time:____________
Notes:______________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
C:\My Docs\Manuals\609A-708 Pipeliner II-C.wpd June 16, 1997
Summary of Contents for Pipeliner II 609A
Page 12: ...9...
Page 13: ...10...
Page 27: ...24...
Page 34: ...31...
Page 40: ...37 Undercutting 1 Reduce power 2 Reduce welding speed 3 Shorten arc length...
Page 43: ...40 Remote Pendant...
Page 46: ...43 14 0 ELECTRODE EXTENSION OFTEN NEGLECTED WHEN USING SELF SHIELDED CORED WIRES...
Page 47: ...44...
Page 48: ...45...
Page 49: ...46 15 0 PREVENTING THE EFFECTS OF MOISTURE CONTAMINATION OF FLUX CORE WIRE...
Page 50: ...47...