7
3.5.4 Welding
Area
Do not weld in locations close to chlorinated vapors coming from
degreasing, cleaning or spraying operations. The heat and rays from the
arc react with the vapors to form highly toxic PHOSGENE. Work in a
confined space only if it is being adequately ventilated, and if ventilation is
not adequate, wear an air-supplied respirator (see ANSI 2.37).
3.6
COMPRESSED GAS CYLINDER HANDLING:
Follow precautions below and those outlined in CGA Standard P-1, Precautions
For Safe Handling Of Compressed Gases in Cylinders.
3.6.1 Cylinders
Handle carefully to prevent damage. Keep away from welding cables or
other electrical circuits. Use only cylinders with name of gas marked on
them; DO NOT rely on color identification. Close valves on empties and
return promptly. Secure cylinders so they cannot be knocked over. Keep
temperature below 130 degrees F.
3.6.2 Pressure
Regulators
Use the correct regulator for the gas and cylinder at hand. Remove any
suspected faulty regulator and return to manufacturer's service center for
repair.
3.7
EQUIPMENT WARNING LABELS:
Inspect all precautionary labels on the equipment.
3.8
ADDITIONAL SAFETY AND HEALTH INFORMATION:
3.8.1 ANSI Standard Z49.1, SAFETY IN WELDING AND CUTTING. Order
from the American Welding Society, P. O. Box 351040, 550 N. W.
LaJeune Road, Miami, FL 33125.
3.8.2 ANSI Standard Z87.1, SAFE PRACTICE FOR OCCUPATION AND
EDUCATIONAL EYE AND FACE PROTECTION. Order from American
National Standards Institute, 1430 Broadway, New York, NY 10018.
3.8.3 ANSI Standard Z241.1, Standard for Men's Safety-Toe Footwear. Order
from same as item 2.
3.8.4 American Welding Society Standard F4.1-80, WELDING AND CUTTING
CONTAINERS WHICH HAVE HELD COMBUSTIBLES. Order same as
for Item 1.
3.8.5 OSHA Standard 29 CFR, Part 1910, Subpart Q, WELDING, CUTTING
AND BRAZING. Order from Superintendent of Documents, U.S.
Summary of Contents for Pipeliner II 609A
Page 12: ...9...
Page 13: ...10...
Page 27: ...24...
Page 34: ...31...
Page 40: ...37 Undercutting 1 Reduce power 2 Reduce welding speed 3 Shorten arc length...
Page 43: ...40 Remote Pendant...
Page 46: ...43 14 0 ELECTRODE EXTENSION OFTEN NEGLECTED WHEN USING SELF SHIELDED CORED WIRES...
Page 47: ...44...
Page 48: ...45...
Page 49: ...46 15 0 PREVENTING THE EFFECTS OF MOISTURE CONTAMINATION OF FLUX CORE WIRE...
Page 50: ...47...