Safety Precautions

•  In small-sized and confined spaces, absolutely make sure to perform welding / cutting

  operations, accompanied by another person.

•  Avoid performing welding / cutting operations in such enclosed areas as much as possible.

•  Take all necessary precautions when moving the machine. The areas where the machine to be 

  transported, parts to be used in transportation and the physical conditions and health of the 

  person carrying out the transportation works should be suitable for the transportation process.

•  Some machines are extremely heavy; therefore, make sure that the necessary environmental 

  safety measures are taken when changing their places.

•  If the machine is to be used on a platform, it must be checked that this platform has suitable load 

  bearing limits.

•  If it is to be transported by means of a haulage vehicle (transport trolley, forklift etc.), make sure 

  of the durableness of the vehicle, and the connection points (carrying suspenders, straps, bolts, 

  nuts, wheels, etc.) that connect the machine to this vehicle.

•  If the machine will be carried manually, make sure the durableness of the machine apparatuses 

  (carrying suspenders, straps, etc.) and connections.

•  Observe the International Labor Organization’s rules on carriage weights and the transport

  regulations in force in your country in order to ensure the necessary transport conditions.

•  Always use handles or carrying rings when relocating the power-supply sources. Never pull 

  from torches, cables or hoses. Be absolutely sure to carry gas cylinders separately.

•  Remove all interconnections before transporting the welding / cutting equipment, each being 

  separately, lift and transport small ones using its handles, and the big ones from its handling 

  rings or by using appropriate haulage equipment, such as forklifts.

Welding /  Cutting in 

Small Sized and

Confined Spaces

Failure To Take

Precautions During

Transport May Cause

Accidents

•  Place your machine on the floor and platforms with a maximum tilt of 10° so that it does not fall 

  or tip over. Choose places that do not interfere with the flow of materials, where there is no risk 

  of  tripping over on cables and hoses; yet, large, easily ventilatable, dust-free areas. To prevent 

  gas cylinders from tipping over, on machines with a gas platform suitable for the tanks, fix the 

  tanks on to the platform; in stationary usage applications, fix them to the wall with a chain in a

  way that they would not tip over for sure.

•  Allow operators to easily access settings and connections on the machine.

Falling Parts May 

Cause Injuries

Improper positioning of the power-supply sources or other equipment can cause serious injury 

to persons and physical damage to other objects.

•  Allow the machine to cool down according to operation cycle rates.

•  Reduce the current or operation cycle rate before starting the welding / cutting again.

•  Do not block the fronts of air vents of the machines.

•  Do not put filters that do not have manufacturer approvals into the machine’s ventilation ports.

Excessive Use Of The

Machine Causes

Overheating

Excessive Use Of The

Machine Causes

Overheating

•  This device is in group 2, class A in EMC tests according to TS EN 55011 standard.

•  This class A device is not intended for use in residential areas where electrical power is supplied 

  from a low-voltage power supply. There may be potential difficulties in providing electromagnetic 

  compatibility due to radio frequency interference transmitted and emitted in such places.

•  Make sure that the work area complies with electromagnetic compatibility (EMC).

  Electromagnetic interferences during welding / cutting operations may cause undesired effects 

  on your electronic devices and network; and the effects of these interferences that may occur 

  during these operations are under the responsibility of the user.

•  If there is any interference, to ensure compliance; extra measures may be taken, such as the 

  use of short cables, use of shielded (armored) cables, transportation of the welding machine to 

  another location, removal of cables from the affected device and / or area, use of filters or taking 

  the work area under protection in terms of EMC.

•  To avoid possible EMC damage, make sure to perform your welding / cutting operations as far 

  away from your sensitive electronic devices as possible (100 m).

This device is not compliant with IEC 61000 -3-12. In case if it is desired to be

connected to the low voltage network used in the home, the installer to make the 

electrical connection or the person who will use the machine must be aware that 

the machine has been connected in such a manner; in this case the responsibility 

belongs to the user.

Summary of Contents for RS 350 MK

Page 1: ...RS 350 MK PRO 90 444 93 53 magmaweld com info magmaweld com 90 538 927 12 62 USER MANUAL...

Page 2: ...kine Sanayi ve Ticaret A Magma Mekatronik may modify the information and the images without any prior notice T m haklar sakl d r Magma Mekatronik Makine Sanayi ve Ticaret A nin yaz l izni olmaks z n b...

Page 3: ...EN MIG MAG WELDING MACHINE TR MIG MAG KAYNAK MAK NES 3 RS 350 MK PRO...

Page 4: ...ing Connections Grounding Pliers Connections Gas Connections OPERATION User Interface Connection to Mains Preparation and Connection of the Torch Selection and Replacement of Wire Feed Rollers Placing...

Page 5: ...ries may occur Make certain that the installation procedures comply with national electrical standards and other relevant regulations and ensure that the machine is installed by authorized persons Wea...

Page 6: ...above precautions If the gas tanks are grouped in a separate zone ensure that they are well ventilated keep the main valves closed when gas cylinders are not in use pay attention to possible gas leak...

Page 7: ...you will perform in such places Do not weld in tanks and pipes which might have previously contained substances that may cause explosions fires or other reactions Welding cutting equipment heats up F...

Page 8: ...areas To prevent gas cylinders from tipping over on machines with a gas platform suitable for the tanks fix the tanks on to the platform in stationary usage applications fix them to the wall with a c...

Page 9: ...nce must be carried out All covers on the body of the machine must be closed and or locked when the device is in use Any changes other than the standard settings without the written approval of the ma...

Page 10: ...materials tape cable ties etc The operator s body and head should be kept as far away from the welding cutting machine and cables as possible Welding cutting and electric cables should not be wrapped...

Page 11: ...With these machines you can weld in a wide range of currents These machines have fan cooling and thermal protection against overheating 1 2 Machine Components Figure 1 Front and Back View 1 6 7 8 9 10...

Page 12: ...Mains Voltage and Frequency Protection Class Rated Welding Voltage Rated Power Rated Mains Current Technical Information As defined in the standard EN 60974 1 the duty cycle rate includes a time perio...

Page 13: ...it Voltage TECHNICAL DATA RS 350 MK PRO 1 5 Accessories STANDARD ACCESSORIES Workpiece Clamp and Cable MIG MAG CO Accessory Set Torch Heater Regulator Gas Hose MIG MAG Mix Argon Accessory Set Torch Re...

Page 14: ...aling welding fumes and gas in confined spaces Observe the operating cycle rates specified on the product label Suspending operating cycle rates can damage the machine and this may invalidate the warr...

Page 15: ...s construction sites and workshops A suitable plug must be connected by a qualified technican Make sure that the grounding cable marked with and a yellow green color is present After connecting the pl...

Page 16: ...If the CO2 heater will not be used connect the gas regulator directly to the gas cylinder Connect one end of the tube hose to the gas regulator and tighten the clamp Connect the other end to the gas...

Page 17: ...g of Voltage and Function settings Displays 0 when no welding is performed When the torch trigger is pressed in idle position without welding the idle operating voltage is displayed Displays the weldi...

Page 18: ...material structure is prevented Setting range 0 1 10 sec Burn Back brn When the welding is terminated clumping occurs at the end tip of the welding wire By means of the burn back function the burning...

Page 19: ...d Setting range 0 10 sec Off Time OFt Stand by time during welding is adjusted in pnt mode During the set time the welding will stop and restart at the end of the period Setting range 0 10 sec Standby...

Page 20: ...pectively Afterwards remove the spiral nut on the torch connector side with a wrench and extend the torch so that it is in flat position and remove the spiral inside the torch After inserting the new...

Page 21: ...ess steel corrugated V grooves for cored wires and U corrugated ones for aluminum If you need to replace the wire feed rollers pull the pressure roller lever toward your side and after lifting the pre...

Page 22: ...r a while For this reason do not connect the nut too tightly or too loosely If the end of the wire is missed the wire can jump like a spring and damage you and others a b c Pass the wire through the w...

Page 23: ...n the pnt mode the welding starts at the moment the trigger is pressed the welding continues until the set time period is on and stands by as long as the off time period The process continues in this...

Page 24: ...e will be displayed in voltmeter and instantaneous welding current will be displayed in ammeter After you have finished working with the welding machine allow the machine to cool down and turn the on...

Page 25: ...fan control The fan is activated when the machine reaches a certain temperature This saves energy and reduces iron dust entering the machine Standby Mode With the active stand by mode when the machin...

Page 26: ...ith dry air each time you replace a welding wire The consumables on the torch should be cleaned regularly It should be replaced if necessary Make sure that these materials are original products for lo...

Page 27: ...s on the torch must be cleaned regularly Improperly selected or worn consumables should be replaced Pressure roller settings must be made correctly The fuse has blown Check the contactor Check the fus...

Page 28: ...n E01 Error Code Error Cause Solution Check visually whether the fan is working or not If the problem continues contact the authorized service Open the front of the air ducts If the problem continues...

Page 29: ...feed motor 1 Free Wire Feed Button As long as the button is held pressed the wire is fed and the gas valve does not operate You can use this button to feed the wire into the torch 2 Free Gas Button A...

Page 30: ...30 www magmaweld com USER MANUAL KULLANIM KILAVUZU RS 350 MK PRO EN Annex 5 2 Spare Parts List 1 2 3 4 5 10 11 13 15 16 17 18 25 27 24 23 28 29 26 19 20 21 22 14 12 8 9 6 7...

Page 31: ...System Diode Group Aybolt Power Connector Pacco Switch Spool Carrier Plastic Swivel Wheel Electronic Card RS Filter Cooling Fan On Off Switch Hall Effect Sensor Primary Secondary Coil 1 15 8 22 4 18 1...

Page 32: ...BREVIATION S1 P1 F1 Br1 TR1 M2 F3 S2 M1 F2 L1 TR2 V1 C1 F4 Coarse Adjustment Switch Heater Outlet Fuse Wire Feed Motor and Wire Feed Board Bridge Diode Main Transformer Wire Feeding Motor Fuse Gas Hea...

Page 33: ...33 www magmaweld com USER MANUAL KULLANIM KILAVUZU RS 350 MK PRO EN RS 350 MK PRO Annex...

Page 34: ...LG LER Teslim Al rken Dikkat Edilecek Hususlar Kurulum ve al ma Tavsiyeleri Elektrik Fi i Ba lant s Kaynak Ba lant lar Topraklama Pensesi Ba lant lar Gaz Ba lant lar KULLANIM B LG LER Kullan c Aray z...

Page 35: ...l elektrik standartlar na ve di er ilgili y netmeliklere uygun oldu undan emin olun ve makinenin yetkili ki iler taraf ndan kurulmas n sa lay n Kuru ve sa lam izolasyonlu eldiven ve i nl giyin Islak y...

Page 36: ...havalanmas n sa lay n gaz t pleri kullan mda de ilken ana vanalar n kapal tutun gaz ka aklar na dikkat edin Argon gibi koruyucu gazlar havadan daha yo undur ve kapal alanlarda kullan ld klar takdirde...

Page 37: ...dikkati g sterin inde daha nce patlama yang n ya da di er tepkimelere neden olabilecek maddeler bulunan t p ve borulara bo dahi olsalar kaynak kesme yapmay n Kaynak kesme i lemi esnas nda y ksek s ca...

Page 38: ...zerine sabit kullan mlarda ise devrilmeyecek ekilde zincirle duvara sabitleyin Operat rlerin makine zerindeki ayarlara ve ba lant lara kolayca ula mas n sa lay n D en Par alar Yaralanmalara Sebep Olab...

Page 39: ...acak ekilde ilerlemelidirler Kaynak kesme kablolar hi bir ekilde sar lmamal d r Kaynak kesme esnas nda makinede manyetik alan olu maktad r Bu durum makinenin metal par alar kendi zerine ekmeye sebebiy...

Page 40: ...nlendirilmek zorundad r Kullan lm makinenizin at k y netimi hakk nda sat c n zdan ve yetkili ki ilerden bilgi edinin At k Prosed r EMF ayr ca kalp pilleri gibi t bbi implantlar n v cut i ine yerle ti...

Page 41: ...olamadan ka n lm t r Bu makinelerle geni bir ak m skalas nda kaynak yap labilirsiniz Bu makineler a r s nmaya kar fan so utma ve termik korumaya sahiplerdir 1 2 Makine Bile enleri Teknik Bilgiler 1 Di...

Page 42: ...Karakteristik ebeke Giri i 3 Fazl Alternatif Ak m Tehlikeli Ortamlarda al maya Uygun Do ru Ak m EN 60974 1 standard nda da tan mland zere al ma evrim oran 10 dakikal k bir zaman periyodunu i erir rnek...

Page 43: ...g lat r ADET 1 1 1 1 7905203503 35 mm 3 m 7920000555 7907000002 7920000531 7920000551 Sipari esnas nda belirtilmelidir OPS YONEL AKSESUARLAR CO2 Is t c Gaz Reg lat r Mix Gaz Reg lat r CO2 Lava MIG 35...

Page 44: ...man emme sistemi kullan n Kapal mekanlarda kaynak duman ve gaz soluma riski varsa solunum aparatlar kullan n r n etiketinde belirtilen al ma evrimi oranlar na uyun al ma evrimi oranlar n s kl kla a ma...

Page 45: ...ze uygun bir fi kalifiye bir elektrik i taraf ndan ba lanmal d r Sar Ye il renkte ve ile i aretlenmi olan toprak kablosunun mevcut oldu undan emin olun Fi i kabloya ba lad ktan sonra bu a amada prize...

Page 46: ...t c kullan lmayacaksa gaz reg lat r n gaz t p ne ba lay n T p hortumunun bir ucunu gaz reg lat r ne ba lay n ve kelep esini s k n Di er ucunu makinenin arkas ndaki gaz giri ine ba lay n ve somununu s...

Page 47: ...Voltaj ve Fonsiyon ayarlar n n g zlemlenmesini sa lar Kaynak yap lmad durumda 0 de erini g sterir Torcun teti ine bo ta kaynak yapmadan bas ld nda bo ta al ma gerilimini g stermektedir Kaynak esnas nd...

Page 48: ...gaz korumas s rd r l r Bu sayede malzeme yap s nda bozulmalar nlenmi olur Ayar Aral 0 1 10 sn Geri Yanma brn Kaynak sonland r ld nda kaynak telinin ucunda topaklanma olu ur Geri yanma fonk siyonu ile...

Page 49: ...n Off Time OFt Punta modunda kaynaktaki bekleme s resi ayarlan r Ayarlanan s re zarf nda kaynak duracak s re sonunda tekrar ba layacakt r Ayar Aral 0 10 sn Uyku Modu SLC Uyku modu ile ayarlanan s re s...

Page 50: ...irin Spirali de i tirmek i in s ras yla nozulu kontak memeyi ve adapt r s k n Ard ndan tor konnekt r taraf ndaki spiral somununu anahtar yard m yla s k p torcu d z olacak ekilde uzat n ve torcun i ind...

Page 51: ...do ru ekip bask makaralar n kald rd ktan sonra tel s rme makaralar n n vidalar n s k n ve mevcut makaralar kart n Kullanaca n z makaralar yerle tirdikten sonra vidalar n tekrar tak p bask makaralar n...

Page 52: ...olmad n kontrol edin Gev eme ve veya geri sarma g zleniyorsa tel ta ma sisteminin vidas n biraz daha s k n Tel tor ucundan k nca nozulu ve kontak memeyi torca geri tak n Teli bir tahta zerine s rerek...

Page 53: ...bi al r 4 konumu uzun s reli ve otomatik kaynak i lerinde kaynak ya kullan m kolayl sa lar Punta modunda ise teti e bas ld an kaynak ba lar belirlenen on time s resi kadar kaynak devam eder off time s...

Page 54: ...l k kaynak gerilimi voltmetrede anl k kaynak ak m ampermetrede g r nt lenecektir Kaynak makinesiyle i iniz bittikten sonra bir s re makinenin so umas n bekleyip a ma kapama anahtar n 0 konumuna getiri...

Page 55: ...n al maz makine s s belirli bir s cakl a ula t nda fan devreye girer B ylece enerji tasarrufu sa lan r ve makine i erisine giren demir tozlar azal r Uyku Modu Aktif edilebilir uyku modu ile makine bel...

Page 56: ...ar yenisi ile de i tiriniz Kablolara ek onar m kesinlikle yapmay n z Havaland rma i in yeterli alan oldu una emin olunuz Kayna a ba lamadan nce torcun ucundan kan gaz debisini debimetre ile kontrol ed...

Page 57: ...indek sarf malzemeler d zenli olarak temizlenmelidir Hatal secilmi veya a nm sarf malzemeler de i tirilmelidir Bask makara ayarlar do ru ekilde yap lmal d r Sigorta at k Konnekt r kontrol ediniz Sigor...

Page 58: ...iyorsa yetkili servis ile ileti ime ge iniz Hava kanallar n n n n a n z Sorun devam ediyorsa yetkili servis ile ileti ime ge iniz Fan al m yor olabilir Hava giri k kanallar n n n kapanm olabilir Makin...

Page 59: ...n panel zerinden ince ayarlar yapabilirsiniz 1 Serbest Tel S rme D mesi D meye bas l tutuldu u s rece tel s r l r gaz ventili al maz Bu d meyi teli torca s rmek i in kullanabilirsiniz 2 Serbest Gaz D...

Page 60: ...60 www magmaweld com TR USER MANUAL KULLANIM KILAVUZU RS 350 MK PRO 5 2 Yedek Par a Listesi 1 2 3 4 5 10 11 13 15 16 17 18 25 27 24 23 28 29 26 19 20 21 22 14 12 8 9 6 7 Ekler...

Page 61: ...50 A308032023 A229900003 A225220106 K405000224 A250001003 A310100007 A834000002 K302200212 Ekler Kaynak Prizi Yaprak Mente e Plastik Tekerlek Kontakt r Pako alter A ma Kapama Anahtar ok Bobin RS 400 U...

Page 62: ...r C1 A IKLAMA KISALTMA S1 P1 F1 Br1 TR1 M2 F3 S2 M1 F2 L1 TR2 V1 F4 Kaba Ayar alter Is t c Prizi Sigorta Tel S rme Motoru ve Tel S rme Kart Diyot K pr s Ana Transformat r Tel S rme Motoru Sigorta Gaz...

Page 63: ...63 www magmaweld com TR USER MANUAL KULLANIM KILAVUZU RS 350 MK PRO RS 350 MK PRO Ekler...

Page 64: ......

Page 65: ......

Page 66: ......

Page 67: ......

Page 68: ...53 magmaweld com info magmaweld com Magma Mekatronik Makine Sanayi ve Ticaret A Organize Sanayi B lgesi 5 K s m 45030 Manisa T RK YE T 236 226 27 00 F 236 226 27 28 20 12 2021 UM_RSMKPRO350_062020_122...

Reviews: