2.3 Connections For MMA Welding
2.4 Connections For TIG Welding
Check the mains voltage before connecting the machine to the mains.
When plugging the power plug into the outlet, make sure that the power switch is set to “0” in the turned-off position.
Check the mains voltage before connecting the machine to the mains.
When plugging the power plug into the outlet, make sure that the power switch is set to “0” in the turned-off position.
Installation
• Start the machine with the on/off switch and check whether the LEDs are on and the cooling fan is working.
• Connect the welding and grounding wires to the welding and grounding cable sockets according to the electrode and the manufacturer of the
electrode and tighten them clockwise.
• Connect the grounding clamp to the workpiece as close as possible to the welding area.
• Adjust the desired current and the machine is ready to weld.
• Below table is given as a reference for current adjustment of mild steel electrodes, please refer to the electrode manufacturer’s recommendations.
• Start the machine with the on/off switch and check whether the LEDs are on and the cooling fan is working.
• TIG torch with a valve should be used.
• Connect the TIG torch power cable to the negative welding socket
(5)
and the earth cable to the positive welding socket
(6)
of the machine.
• Install the Argon gas regulator onto the Argon gas cylinder.
• Connect the gas hose of the torch to the gas regulator.
• Adjust the desired current and the machine is ready to weld.
Covered Electrode
Diameter (mm)
Recommended Welding Current
Rutile
2.0
2.5
3.25
4.0
40-60 A
60-90 A
100-140 A
140-180 A
-
60-90 A
100-130 A
140-180 A
-
60-100 A
70-130 A
120-170 A
Basic
Cellulosic
Diameter of
Electrode
(mm)
Welding
Current
(ADC)
Diameter of
Nozzle
(mm)
Gas
Debit
(lt/dak)
1.0
1.6
6.3
9.5
15-70
30-150
6-8
6-8
Figure 2: TIG Welding Connections