EN
www.magmaweld.com
36
USER MANUAL | KULLANIM KILAVUZU
ID 500 M/MW PULSE
4.2 Error Codes
An error message is displayed when the mains voltage is wrong or thermal. If you do not want the welding performance to be affected during the
installation process, the parameters such as wire diameter, torch, consumables used in the torch, wire type, wire diameter and gas type should be
taken into account.
E01
Communication Error
• Contact the authorized service.
• Contact the authorized service.
• Contact the authorized service.
• Contact the authorized service.
• Check the mains connection cables and vol-
tage. Make sure that the correct voltage in-
put is provided. If the mains voltage is
normal, contact the authorized service.
• Check the mains connection cables and vol-
tage. Make sure that the correct voltage in-
put is provided. If the mains voltage is
normal, contact the authorized service.
• Visually inspect the fan for proper operation.
Please contact the authorized service if it
does not operate.
• Open the air ducts.
• There may be problems at different points in
the machine.
• Fan may not be operating
• The machine may have been overloaded.
• There may be problems at different points in
the machine.
• Mains voltage may have decreased.
• Temperature sensor may have failed or there
may be an electrical connection problem.
• Mains voltage may have increased.
• The air inlet and outlet ducts may have been
blocked.
• The machine operating environment can be
extremely hot or lack of air.
• The machine’s run time rate may have been
exceeded.
• Ensure that the machine is placed in an area
where it can work operate comfortably.
• Wait for a while to allow the machine to cool
down. If the failure disappears, try to run the
machine at lower amperage values.
E02
E03
E04
E05
E06
Thermal Protection
Overcurrent Failure
Low mains voltage
Temperature Sensor
Reading Failure
High mains voltage
Error Code
Error
Reason
Solution
Maintenance and Service