EN
38
www.magmaweld.com
USER MANUAL | MANUEL D’UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
ID 400 MK PULSE EXPERT / ID 400 MKW PULSE EXPERT
4.3 Error Codes
An error message is displayed when the mains voltage is wrong or thermal. If you do not want the welding
performance to be affected during the installation process, the parameters such as wire diameter, torch,
consumables used in the torch, wire type, wire diameter and gas type should be taken into account.
E01
Communication
Error
• Contact the authorized service
• There may be problems at different
points in the machine
• Fan may not be operating
• The air inlet and outlet ducts may
have been blocked
• The machine operating environment
can be extremely hot or lack of air
• The machine’s run time rate may have
been exceeded
E02
Thermal
Protection
• Check the mains connection cables
and voltage. Make sure that the
correct voltage input is provided.
If the mains voltage is normal,
contact the authorized service
• Mains voltage may have decreased
E04
Low Mains
Voltage
• Contact the authorized service
• Temperature sensor may have failed
or there may be an electrical
connection problem
E05
Temperature
Sensor Reading
Failure
• Check the mains connection cables
and voltage. Make sure that the
correct voltage input is provided. If
the mains voltage is normal, contact
the authorized service
• Mains voltage may have increased
E06
High Mains
Voltage
Error Code
Error
Reason
Solution
• Visually inspect the fan for proper
operation. Please contact the
authorized service if it does not
operate
• Open the air ducts
• Ensure that the machine is placed
in an area where it can work operate
comfortably
• Wait for a while to allow the machine
to cool down. If the failure
disappears, try to run the machine at
lower amperage values
E03
• Contact the authorized service
• Contact the authorized service
• The machine may have been
overloaded
• There may be problems at different
points in the machine
Overcurrent
Failure
Maintenance and Service
Summary of Contents for ID 400 MK PULSE EXPERT
Page 177: ......