![Magmaweld ID 300 M User Manual Download Page 29](http://html1.mh-extra.com/html/magmaweld/id-300-m/id-300-m_user-manual_3555221029.webp)
29
www.magmaweld.com
USER MANUAL | KULLANIM KILAVUZU
ID 300 M / MW
EN
1-Free Wire Feed Button
As long as the button is held pressed, the wire is fed and the gas valve does not operate. You can use this button to feed
the wire into the torch.
2-Free Gas Button
When the free gas button is pressed, the gas will come for 30 seconds and if the free gas button is not pressed again
within 30 seconds, the gas flow will stop after 30 seconds. If the free gas button is pressed again within 30 seconds, the
gas flow will stop as soon as it is pressed. With the free gas button, gas flow is enabled and wire feed does not run. You
can use this button to change the gas in the system after a gas change.
Free Wire Feed
Button
Free Gas
Button
5.1 Fine Settings in the Wire Feed Unit
ANNEX
Annex