System Error
System Error
Wire Feeder Error
Torch Connection
Error
• Contact the authorized service
• Contact the authorized service
• Check wire basket, reel / reel press
and torch connections
• If the problem continues, contact the
authorized service
• Check torch and torch connections
• If the problem continues, contact the
authorized service
• There may be a hardware error
• There may be a hardware error
• There may be an error in wire feeding
• The torch or torch connections
may be faulty
E19
Thermal
Protection
(Secondary)
• Visually check if the fan is working
• If the problem continues, contact the
authorized service
• Unblock the front of the air ducts
• If the problem continues, contact the
authorized service
• Fan may not be working
• The front of the air inlet - outlet ducts
may be blocked
• The machine working environment
may be too hot or stuffy
• The uptime of your machine may have
been exceeded
• Make sure that the working
environment of the machine is not
excessively hot or stuffy
• If the problem continues, contact the
authorized service
• Allow the machine to cool down by
waiting for a while. If the fault
disappears, try to use the machine at
lower amperage values
• If the problem continues, contact the
authorized service
• Make sure that the torch shield is
correctly fitted to the machine
• If the problem continues, contact the
authorized service
• Torch shield may not be installed or
properly fitted
E27
Torch Shield Not
Installed
E26
• Check your air / gas connections,
make sure that the inlet pressure
is appropriate. If the inlet pressure is
normal, contact the authorized
service
• Inlet pressure may be low
Inlet Pressure
Low
E14
E16
E17
E18
E20
E21
E22
E23
E28
E15
System Error
System Error
System Error
System Error
Remote Control
Communication
Error
• Contact the authorized service
• Contact the authorized service
• Contact the authorized service
• Contact the authorized service
• Check remote control connections
• If the problem continues, contact the
authorized service
• There may be a hardware error
• There may be a hardware error
• There may be a hardware error
• There may be a hardware error
• There may be an error in the remote
control connections
Solution
Error
Error Code
Cause
Maintenance and Service