EN
24
www.magmaweld.com
USER MANUAL | MANUEL D’UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
ID 500 TW DC PULSE
6- Adjustment Button
TIG Mode;
• With its 100 program memory feature, it can save your parameter settings. You can recall them as
required by your work type. By this means, each time you change the work, you will not have to set
parameters; the production standard will be preserved. Whichever memory (job) number is
selected, all settings will automatically be saved in that number.
• Change the program number for different parameter entries.
• The display above the program button shows which parameter you have changed in the program.
• There are 100 programs available between 0-99.
• You can switch to the other program by pressing the program button once, if you press and hold, you
can switch between the programs quickly.
MMA Mode;
• (U) When you want to see the welding output voltage, you can see the voltage unit by pressing the
button once. You can switch to the ampere unit by re-pressing the button and display the current
value (A) on the digital display.
7- Program Memory
8- Digital Display
The adjustment knob allows current setting in all welding methods and parameter changes in all
functions. The setting will be made by turning right and left and the set values will be displayed on the
digital display.
The set welding current, parameter values and error codes can be monitored visually on the digital
display.
Operation
Summary of Contents for 513250P2M0
Page 1: ...ID 500 TW DC PULSE 90 444 93 53 magmaweld com info magmaweld com 90 538 927 12 62 USER MANUAL...
Page 64: ...RU 64 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU ID 500 TW DC PULSE...
Page 67: ...RU 67 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU ID 500 TW DC PULSE...
Page 71: ...RU 71 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU ID 500 TW DC PULSE...
Page 126: ......
Page 127: ......
Page 129: ......
Page 130: ......
Page 131: ......