Cleaning & Maintenance
MKE Series Electric Griddle
L20-369 REV. 2 (05/12)
13
5.4.3. Control Box & Electrical Components
Verify amp-draw is within range as compared to the information on the data plate.
Verify that heating contactors are in good condition. Check for worn or pitted contacts. Verify that
wires are tight and in good condition.
Verify that all components (transformer, terminal block, relays, etc…) are in good condition. Verify
that wires are tight and in good condition.
Verify enclosures are free of leaks. Check for water stains and wet surfaces.
Verify that the covers and panels are intact and provide a safe condition. Check for loose parts.
Verify power cord is in good condition. Check for frayed or exposed wires.
5.4.4. Systems Operation Inspection
Check all wire terminations, check for broken, or frayed wires.
Check temperature calibration.
Check thermostat operation and features for proper operation.
Verify all components are in good physical condition.
Ensure that all components are clean, and do not have any grease or water damage.
5.5. Ventilation Hood
Proper ventilation hood operation is very important for the correct operation of this appliance and the
safety of personnel. The ventilation hood should be inspected at the time of installation of this appliance to
insure that it will operate properly in conjunction with the appliance. Perform a regular schedule of
examination, in accordance with local and national codes. In North America, ANSI/NFPA 96 latest edition
and/or local codes must be followed.
Summary of Contents for MKE SERIES
Page 20: ...Accessories MKE Series Electric Griddle L20 369 REV 2 05 12 20 Figure 14 ...
Page 21: ...Accessories MKE Series Electric Griddle L20 369 REV 2 05 12 21 7 Notes Page ...
Page 22: ...Notes MKE Series Electric Griddle L20 369 REV 2 05 12 22 This Page Intentionally Left Blank ...
Page 23: ...Notes MKE Series Electric Griddle L20 369 REV 2 05 12 23 This Page Intentionally Left Blank ...