Page 16
2.5.2. Pebble Effect Layout (Natural Gas Only)
The fire is supplied with ceramic pebble sets
as follows:-
E16
E18
EV16
EV18
Large
Pebbles
(A, B & K)
18 22 15 18
Medium
Pebbles
(C & D)
3 4 8 10
Flat
Pebbles
(H)
4 4 4 4
Front
Pebbles
(E)
6 7 6 7
Aeration
Tubes
4 6 4 6
For models ME16 and ET16 refer to
Figure
24
.
For models ME18 and ET18 refer to
Figure
25
.
For model EV16 refer to
Figure 26
.
For model EV18 refer to
Figure 27
.
NOTE: When placing pebbles on the tray
ensure the lettering on them is facing down
and into the fire. After every step of pebble
laying ensure that they are stable.
Proceed with the pebble layout as follows:-
1. Unpack
the
aeration tubes, Pebbles H,
& E
and place them on the tray as
shown in the relevant figure ensuring
that the port holes and the cross ignition
slot on the right hand side remain clear.
Note that the aeration tubes should be
placed on their back, with the legs facing
up ensuring that as few port holes are
blocked as possible.
2. Using Pebbles
A, B & K
position as
shown to form the second layer.
3. Using
Pebbles
A, B, C & D
position as
shown to form the front and third layers.
4. Using the remaining Pebbles
A
, form the
final layer.
5. Small adjustments to the top layer may
be made to alter the flame pattern if
desired flame after the fire has been
turned on. A small pair of tongs should
be used for this.
6. It is recommended that the pebbles be
left alone once the desired flame pattern
has been achieved.
Constant moving
of the pebbles causes the pebbles to
disintegrate and/or cause
discolouration
.