Page 27
3.5. Ventilation
This model does not normally require any additional ventilation in the room that it is fitted in.
However, if spillage is detected during spillage test additional ventilation may be required. In
GB reference should be made to BS 5871 Part 2 and in IE reference should be made to the
current edition of I.S.813 which makes clear the conditions that must be met to demonstrate
that sufficient ventilation is available.
If provided, any purpose provided ventilation must be checked periodically to ensure it is free
from obstructions.
When fitting the fire in Northern Ireland (NI), purpose provided ventilation must be provided in
accordance with the rules in force.
In other EC countries equivalent rules in force must be used.
3.6. Technical Data
Natural Gas Models
LPG Gas Models
Nominal maximum heat input
6.0 kW (gross)
5.7 kW (gross)
Setting pressure (Cold)
13.5 mbar ±0.2 mbar
36.5 mbar ±1.0 mbar
Minimum heat Input
2.6 kW (gross)
2.6 kW (gross)
Minimum setting pressure(Cold)
3.0 mbar ±0.2 mbar
6.5 mbar ±0.5 mbar
Gas
G20 (Natural Gas)
G31 (LPG)
Injector Size
440
170
Gas inlet connection
8mm
8mm
Control valve
BM/MaxitrolS
BM/MaxitrolS
Pilot
SIT OxyPilot 9039
SIT OxyPilot 9223
Weight
8.9 kg
Efficiency Class
II
3.7. Pressure Test Point Location
Valve
Inlet Pressure
Test Point
Figure 50 - Pressure Test Point Location