MAGICFX
®
SMOKEBUBBLE BLASTER
—
User and Installation Manual
9
The safety address cannot be the same as (one of) the operational address(es).
Operating of these addresses results in the following:
DMX Address
DMX Value (decimal)
Result
Safety address
0
99
Device disabled
100
155
Device enabled
156
255
Device disabled
Start address
(Bubble setting)
0
127
50 % bubble capacity
128
255
100 % bubble capacity
Start a 1
(Smoke setting)
0
85
No smoke
86
170
50 % of bubbles contain smoke
171
255
100 % of bubbles contain smoke
Start a 2
(Fan speed)
0
9
Fan OFF
10
255
Minimal speed -> Full speed
Start a 3
(Go trigger)
0
199
Effect OFF
200
255
Effect ON
Operation of the DMX addresses
When you link multiple machines with DMX, we advise you to use the same Safety
address for all machines.
CAUTION
Always plug in a DMX Terminator into the DMX output of the final
unit in the control sequence. Using a DMX Terminator improves
signal reliability.
1.7
DISPLAY PANEL
MAIN MENU
DMX/RDM SETTINGS
BACK
PREV
NEXT
SELECT
Display panel
The display panel is located on the backside of the MAGICFX
®
SMOKEBUBBLE BLASTER.
Check the following menu structure for all options in the menu. Use the buttons for
navigation and selection. The left-hand LED blinks red when DMX is active. The right-
hand LED continuously lights red when an error is present.