Magicar M880AS Installation Manual Download Page 43

 

45 

EN 

Functions description: 
 

1-01

      When  on,  the  engine  remains  running  after  the  hand  brake  has  been  pulled,  ignition  is  off  and  the 

doors  are  closed.  While  the  engine  running,  lights  are  flashing,  remote  is  displaying  the  remaining  time  of 
engine running. You can set 1, 3 of 10 minutes of engine running. 

1-02

 

When on, the alarm will try to start the car up at the pre-set time. The function requires activating the 

function on the remote, setting the time of the start up and setting the reservation mode.  

1-03 

Setting the engine running time when remotely started.  

1-04

  

When on, you can enter a 4-digit emergency code to cancel the alarm and open the car.  

1-05

 

By choosing this option, you can set up the conditions for a reservation mode set-up. For reservation 

mode setting to carried out, transmission must be in a neutral position, emergency brake pulled up with the 
engine  running.  By  turning  ignition  off  the  engine  remains  running  and  reservation  mode  will  be  set  after 
choosing the option in programming menu 1-05. When choosing option No.3, the alarm will arm. Option No.4 
is  legacy  mode  of  reservation  mode  not  necessary  connect  hand  brake  wire.  When  door  is  closed  and 
ignition  is  switched  off,  engine  remains  running  until  door  opens  and  closes  again.  When  alarm  will  arm, 
reservation mode will be set. If door is opened and ignition is off, engine will be stopped without reservation 
mode set up. 

1-06

 

When on, alarm will warn of the door opened by flashing the lights. 

1-07

 

You  can  set  the  time  for  heating  in  diesel  cars.  It  is  also  possible  to  set  the  time  during  which  the 

alarm will keep the ignition and accessories on when remotely started.  

1-08

 

When on, alarm will warn that the hood is open by flashing the lights. 

1-09

 

you can choose the type of engine sensing.  

 - alternator 

– input 12V required immediately after the engine is started and less than 5V when turned off. 

 - revs 

– you can use the sensor’s impulses based on the revs. Use this option for CAN bus connection.   

1-10

 

It allows you to enter the valet mode in two ways: 

 - simple access 

– by turning ignition on/off 3 times in row 

 - secure access 

– by turning ignition on/off 3 times in row and entering a 2-digit PIN code by the button on 

the back side of RPS. 

1-11

 

In  case  of  using  the 

IG  kill

  function,  the  blocking  output    is 

–  active  (on  -250mA)  when  armed,  - 

inactive  during  a  remote  starting  and  disarmed;  in  case  of  using  the  PANIC  function  when  disarmed,  the 
output will be activated after 30 sec. In case of using the S

tart kill 

function, blocking output is 

– active when 

armed and remotely started, - inactive when disarmed; in case of using the PANIC function when disarmed, 
the output will be activated immediately.  

1-12

    It  is  possible  to  set  up  a  delayed  reaction  to  opened  door  contacts  when  turning  on  the  alarm.  The 

function is supposed to be used with indirect closed doors scanning (from the roof light, etc.) 

1-13   

It  allows  you  to  deactivate  a  ultrasonic  sensor  by  using  remotely  starts.  After  cancel  remote  start 

ultrasonic sensor is activated again. 

1-14

  This  function  is  available  with  CAN  BUS  Magicar  module.  In  case  of  using  the 

Read  only

  function, 

Magicar only read CAN information (open door, trunk, hood, lock/unlock with OEM remote, etc.) 
 

In case of using the 

Read and Write

 function, Magicar can also control lock/unlock, lights and klaxon 

except closing windows. 

In case of using the 

Read, Write and close windows

, Magicar can also close windows when armed.* 

1-15

  When option No.1 is chosen, after pressing button 

III

 system unlock the door, disarming and open the 

trunk. When option No.2 is chosen, after pressing button 

III

 system only open the trunk, not unlock the door 

and not disarming. Trunk input will be able trigger system when trunk is closed. 

1-16 

 The function automatic rearming is possible to disable by option II 

– in this case after alarm disarming, 

countdown will not start and alarm is not arming itself. If factory setting 

– option I is set, after alarm disarming 

, countdown started and after 30 seconds alarm is activated again (if door is not open) 

1-17 

 If option I is set, when trunk is open (alarm is disarmed), reservation mode is cancelled. If option II is 

set, when trunk is open, reservation mode still exists. 

1-18 

 The siren output can by selected for offered siren or for klaxon control.

 

1-19  

Option 

Standard 

is dedicated for all vehicles with start procedure by key

.

 Option 

for START button 

 

is dedicated for vehicles with start procedure by OEM START button. 

 

* See possible function Module CAN BUS Magicar in Table of functions depending on car type. 

For remote start is recommended to use wire for hand brake input. 

 
 
 
 
 
 

Summary of Contents for M880AS

Page 1: ...artom motora Mont ny manu l Autoalarm s integrovan m pagerem a d lkov m startem motoru Mont n manu l Car alarm with two way remote and remote start system Installation guide K tir ny t vvez rl s t vin...

Page 2: ...Slovensky Strana 3 esky Strana 20 English Page 37 Magyarorsz g Oldal 54 SK CZ EN H...

Page 3: ...enu 1 10 Programovacie menu 2 12 VIII RE IM V STRA N CH SVETIEL 13 IX SERVISN RE IM 13 Vstup do servisn ho re imu bez nastaven ho PIN k du 13 Vstup do servisn ho re imu s nastaven m PIN k dom 14 Deakt...

Page 4: ...ednotliv ch komponentov je potrebn venova zv en pozornos umiestneniu mikrovlnn ho interi rov ho senzora ak sa montuje Nako ko tento senzor pracuje na magnetickom princ pe je citliv aj na magnetick pol...

Page 5: ...a pod Pri preberan auta od z kazn ka skontrolujte funk nos elektroniky auta spolu so z kazn kom Pou vajte len bezpe n n radie Pri kontrole vodi ov pou vajte multimeter Pri aut ch s airbagom mus te pre...

Page 6: ...a typu nap jania svetiel 1 fialov v stup na smerov svetl V stup sp na nap tie priveden na erveno biely vodi KON1 2 fialov v stup na smerov svetl V stup sp na nap tie priveden na erveno biely vodi KON1...

Page 7: ...na ov reaguj ci na 12V 5 biely ierny havenie Zap ja sa len u dieselov ch motorov Ak je pri dia kovom tartovan na tomto vodi i zaznamenan sign l je spusten havenie syst m sa automaticky prepne do re im...

Page 8: ...ame umiestni len ip alebo k s nevyfr zovanou kovovou as ou Vodi e by passu erven Zapojte na zelen vodi alarmu KON1 ierny Zapojte na lto biely vodi alarmu KON5 Slu ku ktor je pripojen k druh mu vodi u...

Page 9: ...utomatick prevodovka nepreru en manu lna prevodovka POZOR Pri preru en programovacej slu ky je mo n dia kovo tartova kedyko vek Preto smie by slu ka preru en len u ut ktor sa daj na tartova len v polo...

Page 10: ...acej jednotky alarmu na displeji ovl da a sa zobraz nadpis FAIL a programovanie sa preru Programovacie menu 1 Pri otvoren ch dver ch a zapnutom zapa ovan stla te s asne tla idl I a II na 2 sek pre vst...

Page 11: ...n sledn m zadan m 2 miestneho PIN k du pomocou tla idla na zadnej strane RPS senzora 1 11 V pr pade pou itia funkcie IG kill je v stup blokovania akt vny zopnut 250mA pri zapnutom alarme neakt vny po...

Page 12: ...ri tartovan 2 05 Nastavenie mo nosti uzamkn vozidlo po ukon en dia kov ho tartovania 2 06 Funkcia nastavuje re im ovl dania svetiel alarmom Normal ur en pre priame ovl danie v stra n ch svetiel kladn...

Page 13: ...tla Obr 1 Je mo n nastavi v Programovom menu 2 06 re im sp nania plynul a impulzn V pr pade pou itia ovl danie svetiel cez sp na v stra n ch svetiel je mo n pripoji vstup pre parkovacie svetl KON 4 8...

Page 14: ...displeji bude blika nadpis SLEP Deaktiv cia servisn ho re imu Servisn re im m ete deaktivova len pomocou dia kov ho ovl da a Stla te s asne tla idl I a III na 0 5 sekundy Sir na 1x p pne a svetl 2x bl...

Page 15: ...otvrdenie pr slu n m po tom bliknut modrej LED 9 Pokra ujte opakovan m bodov 7 8 pre tretie a tvrt slo V ho k du 10 Po zadan tvrt ho sla svetl blikn pre potvrdenie naprogramovania k du Zmena PIN k du...

Page 16: ...otor na riadenie 12V Odomkn Zamkn lt ierna lt lt biela zelen ierna zelen biela zelen NC1 NC2 COM1 NO1 COM2 NO2 KON3 sp na v predn ch dver ch Obr 2 Zapojenie pre centr lne zamykanie so sp na om v predn...

Page 17: ...iely 1 fialov poistka 15A 2 fialov 3 biely 4 siv 5 siv biely KON 2 v stup svetl v stup svetl v stup sir na vstup spolo n kufor v stup kufor Spolo n vodi Polarita EM Elektromagnet mechanizmu kufra v st...

Page 18: ...MAGICAR M880AS Autoalarm s integrovan m pagerem a d lkov m startem motoru Mont n manu l...

Page 19: ...V N VOLITELN CH FUNKC 26 VIII KALIBRACE FUNKCE RE IM V STRA N CH SV TEL 30 IX SERVISN RE IM 30 Vstup do servisn ho re imu bez nastaven ho PIN k du 30 Vstup do servisn ho re imu s nastaven m PIN k dem...

Page 20: ...notliv ch komponent je nutn v novat zv enou pozornost um st n mikrovlnn ho interi rov ho sn ma e montuje li se Proto e tento sn ma pracuje na magnetick m principu je citliv i na magnetick pole vznikaj...

Page 21: ...el apod P i p eb r n auta od z kazn ka je dobr zkontrolovat funk nost elektroniky auta spolu se z kazn kem Pou vejte pouze bezpe n n ad P i kontrole vodi pou vejte multimetr V p pad aut s airbagem mus...

Page 22: ...pro nap jen sv tel p ipojit na 12V anebo kostru podle typu nap jen sv tel 1 fialov v stup na sm rov sv tla V stup sp n nap t p iveden na erven b l vodi KON1 2 fialov v stup na sm rov sv tla V stup sp...

Page 23: ...n Zapojuje se pouze u dieselov ch motor Je li u d lkov ho startov n na tomto vodi i zaznamen n sign l je spu t no haven syst m se automaticky p epne do re imu diesel a se startov n m za ne a po ukon e...

Page 24: ...ovanou kovovou st Vodi e by passu erven Zapojte na zelen vodi alarmu KON1 ern Zapojte na lut b l vodi alarmu KON5 Smy ku kter je p ipojena k druh mu vodi i by passu um st te na m sto kde se nach z te...

Page 25: ...automatick p evodovka nep eru en manu ln p evodovka POZOR P i p eru en programovac smy ky lze d lkov startovat kdykoliv Z toho d vodu m e b t smy ka p eru ena pouze u aut kter je mo n nastartovat pou...

Page 26: ...n mimo dosah d c jednotky alarmu na displeji ovlada e se zobraz n pis FAIL a programov n se p eru Programov menu 1 Pro vstup do Programov ho menu 1 stiskn te sou asn tla tka I a II na 2 sekundy p i o...

Page 27: ...stn ho PIN k du pomoc tla tka na zadn stran RPS senzoru 1 11 Pou ijete li funkci IG kill pak je v stup blokov n aktivn sepnut 250mA p i zapnut m alarmu Neaktivn je b hem d lkov ho startu a p i vypnut...

Page 28: ...tartov n 2 05 Nastaven mo nosti zamknout vozidlo po ukon en d lkov ho startov n 2 06 Tato funkce nastavuje re im ovl d n sv tel alarmem Norm ln ur eno pro p m ovl d n v stra n ch sv tel kladn m nebo z...

Page 29: ...sp n n plynul anebo impulsn V p pade pou it ovl dan sv tel p es sp na v stra n ch sv tel je mo no p ipojit vstup pro sm rov sv tl KON 4 8 na vodi v stra n ch sv tel jako zp tn kontrola IX SERVISN RE...

Page 30: ...ktivovat pouze pomoc d lkov ho ovlada e Stiskn te sou asn tla tka I a III na 0 5 sekundy Sir na 1x p pne a sv tla 2x bliknou X PROGRAMOV N OVLADA Programov n d lkov ho ovlada e 1 Alarm je deaktivov n...

Page 31: ...o tem bliknut modr LED diody 9 Pokra ujte opakov n m bod 7 a 8 pro t et a tvrt slo Va eho k du 10 Po zad n tvrt ho sla sv tla bliknou pro potvrzen naprogramov n k du Zm na PIN k du P i pou it 2 m stn...

Page 32: ...je motor na zen 12V Odemknout Zamknout lut ern lut lut b l zelen ern zelen b l zelen NC1 NC2 COM1 NO1 COM2 NO2 KON3 sp na v p edn ch dve ch Obr 2 Zapojen centr ln ho zamyk n se sp na em v p edn ch dve...

Page 33: ...alov pojistka 15A 2 fialov 3 b l 4 ed 5 ed b l KON 2 v stup sv tla v stup sv tla v stup sir na vstup spole n kufr v stup kufr Spole n vodi Polarita EM Elektromagnet mechanismu kufru v stup odemykac NC...

Page 34: ...MAGICAR M880AS Car alarm with two way remote and remote start system Installation guide...

Page 35: ...onal functions 43 Programming menu No 1 44 Programming menu No 2 46 VIII CALIBRATION OF THE FUNCTION HAZARD LIGHT MODE 47 IX VALET MODE 47 Entering valet mode without a pin code 47 Entering valet mode...

Page 36: ...de II PLACING When fitting each component consider properly the right place for a microwave interior sensor if fitted Since this sensor is working on magnetic principle it is very sensitive to a magne...

Page 37: ...ervos diodes relays etc When receiving a car from a customer check functionality of electronics of a car Use secure equipment only When checking the wires use a multimeter When dealing with cars with...

Page 38: ...ect on 12V or earth depending on the type of lights power supply 1 purple Signal lights output It switches voltage in red white wire CN1 2 purple Signal lights output It switches voltage in red white...

Page 39: ...gnal on this wire when remotely started heating is on system will automatically switch into a diesel mode and starting will begin after heating is completed You may connect the input to e g heating co...

Page 40: ...ass wires Red Connect to a green alarm line CN1 Black Connect to yellow white alarm line CN5 Place the loop which is connected to the second by pass wire where the immobilizer code reader is placed In...

Page 41: ...ut off Automatic transmission Not cut off manual transmission Attention When the loop is cut off you can start remotely at anytime Therefore the loop can only be disconnected in cars that can be start...

Page 42: ...beep you are out of programming menu area Start again by the step 1 Failure notice If the remote happened to be out of the range when programming changes it will display FAIL notice and the programmin...

Page 43: ...on the back side of RPS 1 11 In case of using the IG kill function the blocking output is active on 250mA when armed inactive during a remote starting and disarmed in case of using the PANIC function...

Page 44: ...set the lights control by the alarm mode normal mainly for direct control of hazard lights by or continuous pulse designed to sequential control of directional lights see page 47 2 07 Duration of engi...

Page 45: ...ulse mode It is possible connect directional light input CN4 8 to wire of directional light as feedback control if sequential control mode is selected IX VALET MODE You can access the valet mode of th...

Page 46: ...et mode only by using the remote control Push together shortly buttons I and III Siren will beep once and lights will flash twice X REMOTE CONTROLS PROGRAMMING Remote control programming 1 Disarmed 2...

Page 47: ...ering the third and fourth number of your code 10 After entering the fourth number lights will flash to confirm that the program code has been accepted Changing PIN code PIN code is set as the factory...

Page 48: ...motor at the control level are required 12V Unlock Lock yellow black yellow yellow white green black green white green NC1 NC2 COM1 NO1 COM2 NO2 CN3 CN3 Front door switch Fig 2 Original central power...

Page 49: ...COM 4 black 3 green 2 yellow 1 white 1 purple fuse 15A 2 purple 3 white 4 grey 5 grey white CN 2 Light NO Light NO 12V output to siren Trunk COM Trunk N O Common wire Trunk wire Trunk solenoid Unlock...

Page 50: ...MAGICAR M880AS K tir ny t vvez rl s t vind t rendszerrel ell tott riaszt Beszerel si tmutat...

Page 51: ...EK PROGRAMOZ SA 60 1 es programoz si men 60 2 es programoz si men 62 VIII A V SZVILLOG M D FUNKCI KALIBR L SA 63 IX SZERV Z M D 64 Szerv z m d be ll t sa pin k d n lk l 64 Szerv z m d be ll t sa pin k...

Page 52: ...S Az egyes alkot r szek beszerel sekor fontos hogy pl a mikrohull m rz kel amennyiben beszerel sre ker l elhelyez se megfelel en t rt njen Mivel az rz kel m gneses elven m k dik nagyon rz keny a g pko...

Page 53: ...riaszt rel k beszerel se eset n t rt nik IV VEZET KEZ S LE R SA 1 feh r Kieg sz t kimenet Bekapcsol skor az akkumul torr l t pfesz lts get biztos t Bekapcsolt ind t motor mellett nem m k dik Ez egy k...

Page 54: ...zn lhat k a kieg sz t modulok aktiv l sa sor n is elektromos ablak interf sz Az ind t sg tl s m sodik rel vezet ke a gy jt shoz csatlakozik z ld vez Ind t sblokkol csatlakoztat sa Az ind t vezet kek l...

Page 55: ...lhat Az AUX csatlakoztat sakor minden esetben sz ks ges a t pegys g ellen rz se az aut berendez seinek meg v sa rdek ben Az AUX elektromos ablakhoz t rt n csatlakoztat sa sor n kieg sz t 12V os rel ha...

Page 56: ...net 3 piros 12V os ramell t s V A TENGELYKAPCSOL RZ KEL CSATLAKOZTAT SA Sz ks ges amennyiben az aut ind t sakor sz ks ges a tengelykapcsol ped l lenyom sa A rel csatlakoztat sa a gy jt s illetve a by...

Page 57: ...t 5 m sodpercen bel l v lasszon az al bbiak szerint Nyomja meg az I es gombot az 1 es sz m kiv laszt sa rdek ben Egy szir nas pol s egy l mpafelvillan s Nyomja meg az II es gombot 2 es sz m kiv laszt...

Page 58: ...gy jt st a motor le ll s nem ind that a t vir ny t val 1 06 Bekapcsol sa eset n a riaszt a l mp k villog s val jelzi az ajt k nyitott llapot t 1 07 D zel aut k eset n be ll that a bemeleg t si id 1 0...

Page 59: ...csol s AUX m k d s k zben Be Ki 2 12 Hidegind t s Ki 5 C 15 C 25 C 2 13 les t s kikapcsol s a gy ri t vvez rl vel Bekapcsolva Kikapcsolva 2 14 F nyjelz s k ld se a CAN BUS on Bekapcsolva Kikapcsolva C...

Page 60: ...z egyes opci ban tal lhat Elj r s 1 Kapcsolja be a gy jt st s nyissa ki az ajt t 2 Nyomja le az I II es gombot 2 m sodpercig Ekkor a f nyek felvillannak a szir na pedig egyet csipog 3 2 m sodpercen be...

Page 61: ...en ha elveszett vagy megs r lt a t vir ny t A szerv z m d be ll t sa lehets ges PIN k ddal vagy PIN k d n lk l is programoz si men 1 10 A PIN k d haszn lat val cs kkenthet a szerv z m d jogosulatlan h...

Page 62: ...k egyszer felvillannak 4 A 2 l p sben le rt m don programozza be a t bbi t vir ny t t is Minden egyes t vir ny t eset n visszaigazol skor a l mp k egyszer felvillannak A rendszer automatikusan lez rj...

Page 63: ...tsa a riaszt t 2 Nyissa ki az ajt t s a csomagtart t 3 Adja r a gyujt st 3 szor 3 m sodpercen bel l A szir na s a f nyek 1 szer jeleznek 4 Az RPS szenzor nyom gombj t nyomja meg annyiszor amennyi az...

Page 64: ...Kiny t Z r Elektromos motorkapcsol F vezet k NC1 NC2 COM1 NO1 COM2 NO2 s rga fekete s rga s rga feh r z ld fekete z ld z ld feh r CN3 rintkez s z rt rintkez s ny tott s rga fekete s rga s rga feh r z...

Page 65: ...rga 1 feh r 1 l la biztos t k 15A 2 l la 3 feh r 4 sz rke 5 sz rke feh r CN 2 Jelz f ny ny kimenet Jelz f ny ny kimenet 12V kimenet szir hoz Csomagt r vez rl s bemenet Csomagtart kimenet Polarit s v...

Page 66: ...POZN MKY...

Page 67: ...70 NOTE...

Page 68: ...71 MEGJEGYZ SEK...

Page 69: ...72...

Reviews: