MAGIC FX MFX1201 User Manual Download Page 14

User Manual

 MAGICFX® Stage Flame 

Page 13 

10. READYING FOR USE

CAUTION:

 

This indicates that the equipment may be damaged if procedures are not 
carried out in the proper manner.

 

DANGER WARNING:

 

The MAGICFX® Stage Flame may only be worked on by authorised 
adults. 

 

Prepare the Stage Flame for use as follows: 

Connect a 3-pole DMX cable to the Stage 
Flame. 

 

Optionally, you can link multiple Stage 
Flames together using 3-pole DMX 
cables.

 

3. 

Ensure the Power button is set to “off”. 
Connect the power cable. The Stage 
Flame runs on 230V~ 50/60Hz. 

You can use 

a

 powerCON 

link

 cable to

connect multiple Stage Flame devices up 
to the same power source.

 

2. 

Place the Stage Flame on a flat, solid, and 
stable surface.

 

 

 

For indoor use with aerosol cans, the 
minimum clearance height above the Stage 
Flame is six meters. For indoor use with gas 
bottles, the minimum clearance height is 
seven meters.  
For Big Flame mode, the minimum clearance 
height is at least ten meters. 

1.

Summary of Contents for MFX1201

Page 1: ...PRODUCT CODE MFX1201 VERSION 1 0 DATE 18 10 2017...

Page 2: ...and reliability All products are manufactured in accordance with the European Machinery Directive MAGIC FX handles the entire production in house from concept to finished product We take care of the...

Page 3: ...purposes or situations than specified in this documentation Modifications to the Stage Flame This includes the use of non original spare parts Improper maintenance Unauthorized removal of safety cover...

Page 4: ...ponsibility We are the manufacturer of the product MFX1201 MAGICFX Stage Flame to which this declaration pertains and it is in conformity with the provisions of the following guidelines Machinery Dire...

Page 5: ...ttachments in a secure central location and keep another copy of this manual close to the workplace where the Stage Flame will be used If you are well acquainted with the proper handling of the equipm...

Page 6: ...ECESSARY ACCESSORIES 6 5 3 TYPES OF GAS 6 5 4 CHOICE OF FLAME 7 6 SAFETY 8 6 1 INTRODUCTION 8 6 2 GENERAL SAFETY RULES 8 6 3 EMERGENCY STOP BUTTON 8 6 4 WARNINGS 9 6 5 FEATURES 10 7 PARTS 11 8 ACCESSO...

Page 7: ...e mode where both aerosol can and gas bottle are used at the same time The Stage Flame is DMX controllable One address is used as a safety channel and one address for the flame A third address is used...

Page 8: ...ROSOL CAN GAS BOTTLE Flame height approximately six meters high MODE FLAME HEIGHT MINIMUM CLEARANCE HEIGHT AEROSOL CAN 3M 6M GAS BOTTLE 4M 7M BIG FLAME AEROSOL CAN GAS BOTTLE 6M 10M Table 5 3 DANGER W...

Page 9: ...in the environment Keep the workplace clean Only authorized persons may work with the Stage Flame It not permitted to use the Stage Flame in an environment containing flammable gases or fluids Always...

Page 10: ...t ensure that the text is always visible and legible and that it remains so DANGER WARNING Any missing spoilt or illegible text or icons must be replaced The icons used are shown below Icons Explanati...

Page 11: ...op of the Stage Flame 6 5 FEATURES The Stage Flame has many safety features One of these features checks whether the Stage Flame is moved tilted or is exposed to shocks In these cases the Stage Flame...

Page 12: ...n 2 Power input 3 Power output 4 DMX input 5 DMX output 6 Gas bottle input 7 Display 8 DMX Led 9 MENU button 10 UP button 11 DOWN button 12 RESET button 13 Warning LEDs 14 Cover fasteners 15 Aerosol c...

Page 13: ...REPARATION FOR USE Unpack the Stage Flame Dispose of packaging material without causing harm to the environment Check the device for any possible damage You must report any damage to the device to MAG...

Page 14: ...multiple Stage Flames together using 3 pole DMX cables 3 Ensure the Power button is set to off Connect the power cable The Stage Flame runs on 230V 50 60Hz You can use a powerCON link cable to connec...

Page 15: ...ill turn on making it possible to see in places that would otherwise be dark in the Stage Flame 6 Set the Stage Flame power button to on 5 Connect the other end of the DMX cable male plug to a profess...

Page 16: ...fter the Stage Flame has been in use for a period of time So always let the Stage Flame cool off before replacing the aerosol can Always remember that escaping gas can ignite at high temperatures Afte...

Page 17: ...turned in completely to maximize the flow of gas and create the biggest possible flame We recommend turning the bolt to the maximum opening to get the best results The reducer must never be used with...

Page 18: ...ting flames These options are dependent on the gas sources you choose to use The three options are Option 1 Aerosol can Option 2 Propane cylinder Option 3 Big Flame aerosol can and gas bottle You sele...

Page 19: ...aerosol can and a gas bottle 1 7 After you have set the safety channel you can set the fire channel You select the desired channel by using the UP and DOWN buttons If you have selected the Big Flame o...

Page 20: ...flame should now be emitted from the Stage Flame Before you shoot flames always check that there are no persons in the area near the Stage Flame Ensure that you have a full view of the Stage Flame wh...

Page 21: ...ed the Stage Flame you must set it to safety mode again You put the Stage Flame in safety mode by shutting the safety channel or setting it to a value outside the 40 to 60 range The Stage Flame cannot...

Page 22: ...age Flame is cooled off before you remove the aerosol can and pack up the Stage Flame 4 If a gas bottle was used then this must be closed first before you disconnect the gas hose 3 Turn off the Stage...

Page 23: ...life of the Stage Flame for as long as possible you must regularly clean it and test that it is working properly Regardless of the reason contact MAGIC FX if the Stage Flame does not work properly DAN...

Page 24: ...WWW MAGICFX EU...