background image

User Manual

 MAGICFX® CO2 Power Jet 

Page 7 

6.

SAFETY

6.1 

INTRODUCTION

The CO2 Power Jet has been designed and constructed in such a manner that it can be used safely. 

This applies to the use, the circumstances and the regulations as described in this documentation. 

Reading this documentation and following the instructions are therefore necessary for everyone who is 

authorised to work with the CO2 Power Jet. 

The CO2 Power Jet must be placed and used in surroundings that preferably: 

-

Have a reasonably stable temperature of between 0 and 30ºC.

-

Have a relative humidity degree of no more than 75%.

-

Are reasonably free of dust, corrosive gases and high concentrations of organic vapours.

-

Are not situated in the vicinity of a source of vibration.

6.2 

GENERAL SAFETY RULES 

-

Only use the CO2 Power Jet if there are no people, animals or other objects in the direction of the

output within the output distance. The shooting direction is the direction in which the output pipe

on the CO2 Power Jet is pointed. The output distance depends on the humidity in the air.

-

Make sure that children, unauthorised people and animals do not obtain access to the CO2 Power

Jet!

-

Safety devices may not be removed or disabled.

-

All required safety devices must be in good condition and function properly.

-

Ensure sufficient lighting of the surroundings.

-

Keep the workplace clean.

-

Only authorised persons may carry out work with the CO2 Power Jet.

Summary of Contents for CO2JET II

Page 1: ...PRODUCT CODE MFX1160 VERSION 1 0 DATE 18 10 2017 ...

Page 2: ...are made in accordance with the European Machinery Directive MAGIC FX manages the entire production process in house from the design stages and prototyping to production In short we cover everything from concept to ready to use product Moreover MAGIC FX is Europe s largest supplier of high quality and fireproof confetti products and streamers Thanks to our very large stock levels we can deliver qu...

Page 3: ...the CO2 Power Jet This also includes the use of replacement parts other than the original ones Insufficient maintenance Unauthorised removal of safety caps and or safeguards Incompetent operation of the machine MAGIC FX B V is not liable for any consequential loss in the event of a CO2 Power Jet breakdown Copyright 2012 All rights are reserved Nothing from this manual may be duplicated or kept in ...

Page 4: ...sponsibility We are the manufacturer of the product MFX1160 MAGICFX CO2 Power Jet to which this statement relates and which is in accordance with the provisions of the following Directive s Machinery Directive 2006 42 EC Low Voltage Directive 2006 95 EC EMC Directive 2004 108 EG Pressure Equipment Directive 97 23 EC The following harmonising standards have been applied NEN EN ISO 12100 NEN EN ISO ...

Page 5: ... that the original of this user manual including appendices is kept at a safe and central place It is best that another original or copy is kept close to the CO2 Power Jet at the workplace If you are familiar with these matters then you can use this manual as a work of reference The following standard markings are used in this manual for drawing attention to certain subjects or actions TIP Gives y...

Page 6: ...TION 6 5 1 DESCRIPTION AND APPLICATION OF THE CO2 POWER JET 6 5 2 NECESSARY ACCESSORIES 6 6 SAFETY 7 6 1 INTRODUCTION 7 6 2 GENERAL SAFETY RULES 7 6 3 WARNINGS 8 7 MAIN PARTS 9 8 ACCESSOIRES 10 9 PREPARATIONS 10 10 INSTALLATION 11 11 USAGE 15 12 SWITCHING OFF 15 13 TROUBLESHOOTING 17 14 TECHNICAL DATA 17 15 MAINTENANCE 17 16 GUARANTEE 17 ...

Page 7: ...case of a high degree of air humidity the smoke plume will be larger and in case of a low degree of air humidity it will be smaller The CO2 Power Jet must be connected to a carbon dioxide CO2 bottle with dip pipe The CO2 Power Jet is not suitable for other gases than those described above Any use other than that described above will exclude your supplier from any liability 5 2 NECESSARY ACCESSORIE...

Page 8: ...bly free of dust corrosive gases and high concentrations of organic vapours Are not situated in the vicinity of a source of vibration 6 2 GENERAL SAFETY RULES Only use the CO2 Power Jet if there are no people animals or other objects in the direction of the output within the output distance The shooting direction is the direction in which the output pipe on the CO2 Power Jet is pointed The output ...

Page 9: ...xts or signs if these are absent damaged or illegible Sign and explanation PIC 323 Low temperatures In case of low temperatures a low temperature warning must be issued by means of warning sign 323 This is attached to the top of the CO2 Power Jet Photo Sign and explanation PIC 616 Follow the instructions The operator must be told that he she may only operate the CO2 Power Jet after reading the use...

Page 10: ...User Manual MAGICFX CO2 Power Jet Page 9 7 MAIN PARTS 1 CO2 input 3 4 Quick Connector 2 powerCON input 3 powerCON output 4 Handle 5 LED indicator 6 Lock pin 7 CO2 output pipe 1 2 3 4 5 6 7 4 ...

Page 11: ...the environment Inspect the machine for any damage If damage is noticed this must be reported to MAGIC FX MAGIC FX B V Schouwrooij 27 NL 5281 RE BOXTEL The Netherlands T 31 0 411 63 50 13 F 31 0 411 63 50 12 W http www magicfx eu E info magicfx eu 8 ACCESSORIES Please contact Magic FX for additional accessories ...

Page 12: ...liquid carbon dioxide with dip pipe and consult your gas supplier about the installation instructions guidelines and regulations for the safe use of the CO2 bottles For installing the CO2 Power Jet work in the following manner 2 If required you can adjust the blow pipe to change the direction of the output Pull the lock pin backwards to unlock the pipe and adjust it to the required position 1 Plac...

Page 13: ... or chains to prevent them falling over 4 Now connect the 2m long high pressure CO2 hoses to the CO2 bottles Firmly secure the couplings by hand Turning it by hand will suffice You should only use a wrench if the coupling continues to leak 3 In order to test it you first need to check if the gas valve on the CO2 bottle is still in a closed position Now you can check if the CO2 Power Jet has been i...

Page 14: ...and let it click into place so it is firmly secure 7 Now connect the 3 4 CO2 high pressure hose to the distribution block and check if it is firmly connected 6 Connect the other ends of the CO2 high pressure hoses to the distribution block and check that these are properly connected ...

Page 15: ...ly connected gas can escape If this is the case then turn the couplings tighter until gas is no longer escaping The CO2 Power Jet is now ready for use 9 The CO2 Power Jet is activated as soon as it is powered by a 230V electricity source Use a 230V plug and make sure that the electricity is switched off Plug the CO2 Power Jet into the electricity socket ...

Page 16: ...using the CO2 Power Jet take the following steps The CO2 Power Jet can be operated with a DMX controlled power supply For example a DMX FX Switchpack Ensure that you always have the CO2 Power Jet in clear sight 1 To operate the CO2 Power Jet you press the switch on and off As soon as you press the switch the magnetic valve will immediately open and a white smoke plume will exit from the CO2 Power ...

Page 17: ...cted from the gas bottle and the CO2 Power Jet 3 Disconnect the plug s of the CO2 Power Jet from the power supply 2 Activate the CO2 Power Jet one more time to remove the remaining pressure from the hose Make sure that you only activate the jet when there are no people animals or objects in the trajectory of the cannon 1 Close the valves of the gas bottles ...

Page 18: ...contact your dealer or the technical service of MAGIC FX first in case of uncertainties questions about the CO2 Power Jet works or other issues with regard to the CO2 Power Jet 14 TECHNICAL DATA Measurements and weight Length 270mm 10 6 Width 260mm 10 2 Height 350mm 13 8 Weight 7 5 Kg 16 5lbs Power Input AC 230V 50 60Hz Output AC 230V 50 60Hz Power 100W CO2 Input Liquid CO2 Output CO2 Gas Usage 2 ...

Page 19: ......

Page 20: ...WWW MAGICFX EU ...

Reviews: