background image

  

Short Cycle Time:

 for light odour removal & sanitisation 

  

Intermediate Cycle Time:

 for average odour removal & sanitisation

  

Long Cycle-Time:

 for strong odour removal & sanitisation 

   You can refine your time setting (optional) by pressing the Up or Down (blue) arrow buttons to 

extend or shorten the operation cycle time. Please refer to the reference chart on page six.  

   

Note:

  The cycle time is indicated on the screen in hours and minutes (h= hours, m = minutes). 

For example 3 hours and 20 minutes would be indicted as: 3 h 20 m

  

CAUTION

  

  Before you press the 

“START” “I”

 (green) button verify the area is vacated of 

people, animals, plants and natural rubber. 

   Press  the 

green (I)

 button to 

START

 the cycle. 

   The display will prompt you to 

“Get Out of Room”

 

and the 

amber hazard light 

will begin flashing. 

  

IMPORTANT!

 The system will begin generation of 

Ozone after a 

60 second

 delay in order to allow you 

to leave the room. 

   You must leave the room immediately, swiftly & safely. 

   Remaining in the room while the treatment takes place or entering the room before the cycle 

completes may be hazardous to your health.

   Outside the room you will hear an 

audio alert signal

 indicating the ozone generation has 

begun. 

   Isolate the room, where possible with a lock and warning sign, to prevent access by persons or 

animals.

   After the full operation cycle is completed, including the safe removal of ozone, you will hear a 

second audio alert signal

 indicating that the cycle is complete.

   Upon entering the treated room the display should read: 

Operation Complete

 and the amber light should have 

stopped flashing. 

  

CAUTION

  

  In the event indications do not correspond to 

the above, leave the room immediately and 

contact MAG on 

01422 244733

.

   After the cycle is completed unplug the unit before moving this 

to the next location. 

   If at any point you need to reset the keyboard settings press the 

STOP (O)

 (red) button on the keypad.

Get Out Of Room

For support call 

01422 244733

 or email 

[email protected]

5

Summary of Contents for POCS-500

Page 1: ...MAG OZONE SANITISER USER MANUAL Contact us for information or support 01422 244733 info laundrymachines co uk ...

Page 2: ... 4 5 Activation Deactivation Operating Times 6 Maintenance Service 7 8 9 Troubleshooting 9 Warranty 10 Technical Specifications 11 CONTENTS GENERAL INFORMATION The MAG Ozone Sanitiser is a mobile and easy to use cleaning deodorising system for indoor use The robust product has high safety standards to quickly and efficiently create Ozone then decompose this into Oxygen allowing immediate access to...

Page 3: ...eir vicinity which may block the air flow Place the unit in the centre of the room that is to be treated Prior to removing the grill for maintenance always disconnect the unit from power Avoid electrical shocks This unit is supplied with an earthed cable do not attempt to bypass this Under no circumstances should the unit be used if the front panel grill is loose or missing There are no user servi...

Page 4: ...the machine and only then connect it to the power source socket Ensure the area is free from any persons animals plants or natural rubber e g shoe soles tubing squeegee keyboards Wheel the unit to the centre of the room and avoid the wire as a potential trip hazard Press the STOP red button to Reset The display will present a code followed by the alternating prompt Ready and Set Room Size Select t...

Page 5: ...eave the room You must leave the room immediately swiftly safely Remaining in the room while the treatment takes place or entering the room before the cycle completes may be hazardous to your health Outside the room you will hear an audio alert signal indicating the ozone generation has begun Isolate the room where possible with a lock and warning sign to prevent access by persons or animals After...

Page 6: ...20 38 60 126 52 180 1318 120 1440 X Large 120mm3 178 120 300 598 120 720 2698 180 2880 Up Up Down Short Inter Long Time minutes G D T G D T G D T Room Volume Small 30mm3 17 11 30 70 18 90 28 60 90 Medium 30 60mm3 21 22 45 154 24 180 88 90 180 Large 60 120mm3 50 38 90 666 52 720 598 120 720 X Large 120mm3 238 120 360 1318 120 1440 1258 180 1440 Generation Time G Decomposition D Total Cycle Time T I...

Page 7: ...tenance or service disconnect the power by unplugging the product STEP 1 CLEANING THE DUST FILTER a Remove black front grill panel by unscrewing the six screws your product should now appear as Figure A b Loosen six screws in the frame around the dust filter so you can slide the filter out Note Do not remove the earth cable connected to the grill c Gently slide the filter up and out of its frame a...

Page 8: ...tap water particularly the gaps between the tubes You may use a soft brush to remove any accumulated dirt Do not wet the electrical connector f Repeat the same procedure above from the second Singlet core on the left hand side of Figure D g Allow the Singlets to air dry or use a soft towel h Re mount each Singlet core on its leading screws by sliding it in parallel Remember to re insert the Single...

Page 9: ...rompts Ready but keypad does not function Disconnect and reconnect the power cord Wait for the screen to display Ready Press the STOP red button on the keypad Press the hard RESET yellow button on the keypad Red light fault indication is ON and the display indicates fault code AL Presso stat or AL Micro Switch Make note of the fault code indicated on the display Disconnect unplug the unit and cont...

Page 10: ...nnection with it or its subject matter or formation shall be governed by and construed in accordance with the law of England and Wales Each party the Purchaser and the Company irrevocably agrees that the courts of England and Wales shall have exclusive jurisdiction to settle any dispute or claim including non contractual disputes or claims arising out of or in connection with this agreement or its...

Page 11: ...r air flow obstructed Door Interlock front panel not closed Net Dimensions 50 x 40 x 100 cm with handle attached Packaging Dimensions 66 x 53 x 94 cm with handle detached Ozone outlet duct 4 diameter Weight 34 kg packed for shipment 40 kg Enclosure Metal and ABS Wheels leave no tracks Low EM Noise Certification CE FCC Normal Environmental Conditions Indoor use only Temperature 5 ºC to 40 ºC Humidi...

Page 12: ...MAG OZONE SANITISER USER MANUAL Contact us for information or support MAG Equipment Ltd MAG House Chatham Street Halifax HX1 5BU 01422 244733 info laundrymachines co uk www maglaundryequipment co uk ...

Reviews: