Short Cycle Time:
for light odour removal & sanitisation
Intermediate Cycle Time:
for average odour removal & sanitisation
Long Cycle-Time:
for strong odour removal & sanitisation
You can refine your time setting (optional) by pressing the Up or Down (blue) arrow buttons to
extend or shorten the operation cycle time. Please refer to the reference chart on page six.
Note:
The cycle time is indicated on the screen in hours and minutes (h= hours, m = minutes).
For example 3 hours and 20 minutes would be indicted as: 3 h 20 m
CAUTION
Before you press the
“START” “I”
(green) button verify the area is vacated of
people, animals, plants and natural rubber.
Press the
green (I)
button to
START
the cycle.
The display will prompt you to
“Get Out of Room”
and the
amber hazard light
will begin flashing.
IMPORTANT!
The system will begin generation of
Ozone after a
60 second
delay in order to allow you
to leave the room.
You must leave the room immediately, swiftly & safely.
Remaining in the room while the treatment takes place or entering the room before the cycle
completes may be hazardous to your health.
Outside the room you will hear an
audio alert signal
indicating the ozone generation has
begun.
Isolate the room, where possible with a lock and warning sign, to prevent access by persons or
animals.
After the full operation cycle is completed, including the safe removal of ozone, you will hear a
second audio alert signal
indicating that the cycle is complete.
Upon entering the treated room the display should read:
Operation Complete
and the amber light should have
stopped flashing.
CAUTION
In the event indications do not correspond to
the above, leave the room immediately and
contact MAG on
01422 244733
.
After the cycle is completed unplug the unit before moving this
to the next location.
If at any point you need to reset the keyboard settings press the
STOP (O)
(red) button on the keypad.
Get Out Of Room
For support call
01422 244733
or email
5