background image

Page 19 of 19 

CHAPTER 9 – CERTIFICATE OF CONFORMITY 

 

Company Name:  

MAC International                                           

 
Company Address:  

Kellaw Road, Yarm Road Industrial Estate, Darlington,  
Co. Durham, DL1 4YA, England 

 

As manufacturer the company declares that the following machinery conforms to 
the essential health and safety requirements of the Directives listed below: 

 
Designation:    

HIGH PRESSURE WASHER 

 
Model:   

 

PLANTMASTER ELECTRIC                                  

 
Specification Type:  

13/170, 11/120 

 

Directive Code 

Directive Description 

 

 

2006/42/EC 

Machinery Directive and its amending directives 

2014/30/EU 

Electromagnetic Compatibility Directive and its amending directives 

2000/14/CE 

Noise Emissions Directive 

2002/44/CE 

Vibrations Directive 

 
And have been designed and manufactured to the relevant parts of the following standards: 
 
EN ISO 12100: 2010, EN 60204–1: 2006 + A1:2009, EN 60335-1:2012 + A11:2014,  
EN 60336-2-79:2012 
 
Representative for documentation: 

I hereby declare that the equipment named above has been tested and found to comply with the relevant 
sections of the above referenced specifications.  The unit complies with all essential requirements of the 
Directives.  The Technical Documentation has been drawn up and is held at our Head Office in Darlington. 

Signed by:  

                                                          

Name: S Ruck 

Position: Managing Director      

Place: Darlington 

Date: 30 April 2018 

 

Summary of Contents for MAC PLANTMASTER ELECTRIC

Page 1: ...ASTER ELECTRIC ELECTRICALLY HEATED STATIC PRESSURE WASHER USER INSTRUCTON MANUAL CAUTION Read these instructions before using the machine MAC International Kellaw Road Yarm Road Industrial Estate Darlington Co Durham DL1 4YA ...

Page 2: ...and cautions Chapter 2 Technical description and data Chapter 3 Operating instructions Chapter 4 Fault diagnosis Chapter 5 User maintenance Chapter 6 Warranty Chapter 7 Health and safety information Chapter 8 Visual warning labels Chapter 9 Certificate of conformity ...

Page 3: ... PLATE FIXED TO THE MACHINE 1 Field of use This machine is intended exclusively for washing objects which are surfaces that have been adapted to be treated by the mechanical and thermal action of the water jet The purpose for which the machine is intended to be used must be scrupulously respected and any other use is to be considered as improper 2 Requisite characteristics of operators The machine...

Page 4: ...so could result in expensive damage to the pump and heating elements Also trying to start the machine when frozen will employ the electrical motor overload switch and the machine will have to be reset to operate Only a competent electrician or service engineer should gain access to the electric box Do not direct the water jet at persons animals the machine itself or any object which has an electri...

Page 5: ...ished with a thermal overload protection unit for the main motor which cuts off the electricity supply in the event that the current exceeds the designed amperage Warning The client installer should take further measures to protect the electricity supply by connecting the machine to an ELCB electrical supply 7 Warranty This machine carries a minimum one year parts warranty subject to sales and ser...

Page 6: ...o prevent accidental operation of the jet Personnel must wear appropriate personal protective equipment PPE when operating the pressure washer Appropriate personal protective equipment PPE is to be worn by all personnel carrying out maintenance activities involving diesel fuel and chemical detergents System pressure must be removed before any maintenance activity is carried out or when not in use ...

Page 7: ...the pressure washer is operated without a water supply connected The machine is to be protected from frost and adverse weather conditions where practicable at all times The machine must not be operated when frozen Personnel are to carry out maintenance activities involving chemical detergents and oil with extreme care to prevent damage to the machines components and the environment Prior to the cl...

Page 8: ...e 170Bar 2500 psi 120 Bar 1740 psi Motor specification 5 5hp 7 5Kw 1450rpm 4hp 5 5Kw 1450rpm Immersion element 2 x 12Kw 1 x 12 Kw 1 x 6Kw Shutdown system Timed Timed Temperature 0 80 C 0 80 C Voltage 415v 415 Weight 200kg 200 Kg Dimensions h x w x d 130 x 100 x 80cm 130 x100 x 80 cm Noise emissions 78dB A 78dB A Vibration rating 2 5m s 2 5m s Current 36 Amps 32 Amps ...

Page 9: ...lf of the framework and the upper rear half of the framework The heating elements are fitted into the bottom half of the water tank and at the front to allow for easy access The water pump and electric motor assembly are mounted on rails in the front centre and to the right hand side of the framework The electric box is located above the pump motor assembly in the upper right hand side of the fram...

Page 10: ...he water has been heated fully the heaters will maintain the water temperature whilst switched on The actual operational temperature will vary dependent on the usage Use of the pressure washer is achieved by turning the main on off switch to the start position The heated water is released from the machine via a hose lance and nozzle provided by operation of the lance trigger Water is supplied on d...

Page 11: ...wer on lamp is illuminated 5 Switch on the heaters and allow approximately 90 minutes for the immersion heaters to heat the water in the tank to the maximum operational temperature CLEANING OPERATION 1 Before using the machine ensure that all hoses guns and lances are in good condition and are correct for the application 2 Switch the machine on by moving the main ON OFF switch on the controls to t...

Page 12: ... be adjusted by turning the valve knob clock wise for less or anti clockwise for more 2 Always turn off the chemical prior to switching off the machine SWITCHING OFF To switch the machine OFF proceed as follows 1 Release the handgrip trigger 2 Set the heating elements switch to the OFF position The orange warning light will go out 3 Set the power ON OFF switch to 0FF The green warning lamp will go...

Page 13: ...power cable is damaged Check supply is available Check plug is fitted correctly Check supply switch is on Check suitability of supply Check cable If damaged contact service engineer 2 Water fails to flow from lance Empty water tank Water filter blocked Lance nozzle blocked Check supply Clean or replace as required Clean or replace as required 3 Pressure too low Dirty water filters Detergent valve ...

Page 14: ...tions apply 1 Examine Carry out a survey of the condition of an item without dismantling unless specifically instructed to do so in the relevant task requirement The condition of an item may be impaired by the following Insecurity of attachment Cracks or fractures Corrosion contamination or deterioration Distortion Loose or missing fasteners Chafing fraying scoring or wear Faulty or broken locking...

Page 15: ...ion on release X 8 Apply handgrip trigger safety catch Ensure unable to operate handgrip trigger X X 9 Examine chemical detergent tube and filter Clean or replace filter as required X MAINTENANCE TASKS a Oil pump level check and replenishment weekly 1 Allow sufficient time to allow the pump oil to settle 2 Remove the cabinet front door 3 Check the oil level in the sight glass 4 If replenishment is...

Page 16: ...al at all times 3 The warranty will not apply to any failure resulting from misuse damage abuse or negligence on the part of the user 4 No liability will be accepted under this warranty for damage caused by the fitting or use of other non genuine parts or where any person other than a recommended and authorised service engineer has carried out repair work 5 This warranty does not apply to hoses ca...

Page 17: ... place and in full working order The machine should be used on level ground wherever possible 7 Drainage of the working area should be good and care should be taken to avoid spillages 8 Cables should be inspected regularly Where cables are trailing on the ground extra care should be taken to prevent damage Cables should be properly stored when not in use 9 The pressure washer operating instruction...

Page 18: ...Page 18 of 19 CHAPTER 9 VISUAL WARNING LABELS CE DECLARATION LABEL Warning label 415V ELECTRICS CAUTION Warning label DO NOT DIRECT THE JET OF WATER TOWARDS PEOPLE ANIMALS OR THE MACHINE ITSELF ...

Page 19: ...tromagnetic Compatibility Directive and its amending directives 2000 14 CE Noise Emissions Directive 2002 44 CE Vibrations Directive And have been designed and manufactured to the relevant parts of the following standards EN ISO 12100 2010 EN 60204 1 2006 A1 2009 EN 60335 1 2012 A11 2014 EN 60336 2 79 2012 Representative for documentation I hereby declare that the equipment named above has been te...

Reviews: