-22-
Put top part onto container and close lateral
locks.
4.6.2
Inserting the PE-discharge and disposal
bag
Only dust extractors class M with
special container and rotary valve
in the intake port of types S 35 M
are suitable for use with PE-
discharge and disposal bags.
Operation of the rotary valve
Push rotary valve* from the
inside to the outside, rotate by
180° (see marking) and push
once more to the inside
through the intake port.
Place rotary valve* into the
intake port with the marking ●
pointing upwards.
Push flange completely over intake port, place
top opening of bag across rim of container.
Put top part onto container and close lateral
locks.
4.7 Emptying the container
Only permissible for dusts with
STELs > 1mg/m3
Switch off suction device, pull power plug.
Open locks.
Remove cover and suction hose from container.
Tip out container.
5 Operation
Danger
The electrical tool must be
switched off when it is connected.
When the power plug is plugged in,
the socket outlet is always live,
irrespective of the switch position.
In switch position "0", the socket
outlet can be used as extension
cord (e.g. for lamp).
Connected load: Dust extractor and
connected device max. 16 A.
5.1 Switching on and off
Switch positions 1
(Fig. 1)
Put plug in socket outlet
>0<
=
Dust extractor switched off
>I<
=
Dust extractor switched on without
vibration function
>IR<
=
Dust extractor switched on with
automatic vibration function
>AR<
=
Dust extractor on standby
Only when the tool is switched on will
the
dust
extractor
switch
on
automatically.
After switching off the tool, the dust
extractor will run on for approx. 10 sec.;
this is to prevent any residual amounts
remaining in the hose.