-23-
Set dust extractor to switch position >0<.
Pull power plug when finished.
For storage purposes, fix the suction tube on the
container backplate by inserting it in the
accessory depot*.
The hose ends can be stuck together to prevent
any dirt particles from escaping.
Preselection switch for minimum
volume flow signal (horn and
light) on dust extractors class
“M”.
In mode >AR< and >IR, the following setting is
made, depending on the hose diameter:
Hose inside diameter
Switch position
Ø 49 mm
70 m³/h
Ø 35 mm
70 m³/h
Ø 27 mm
40 m³/h
Ø 21 mm
20 m³/h
For options Ø 27 mm and Ø 21 mm, the speed is
reduced.
The dust extractor S 35 M is equipped with an electric
suction force regulator. The turning knob 2 can be
used to adapt the suction power to the material to be
vacuumed.
Put power plug of the dust extractor into the
socket outlet.
Place switch for normal mode without vibration
function to "I", for normal mode with vibration
function to "IR" or for standby mode to "AR".
Dust extractor is ready for extraction.
After extraction, put switch to "O".
Dust extractor is switched off
Pull power plug of the dust extractor from the
socket outlet.
Clear away mains cable.
Remove electric tool.
The socket outlet 4 is intended for connection of an
electric tool (IR/AR mode).
To avoid excessive start-up peaks, the dust extractor
is equipped with a starting current limit (soft start).
5.1.1
Permanent filter cleaning
The dust extractor is equipped with an electro-magnet
filter cleaning system, that can be used to shake
adhering dust off the folded filter cartridges. The
folded filter cartridges are cleaned alternatively in
succession so that continuous working is guaranteed.
-
Constant fill level monitoring of the filters by
differential pressure measurement for absolutely
accurate need-controlled filter cleaning during
operation.
-
This guarantees a constantly high air flow during
operation, even for critical types of dust.
5.2 Hints and information
-
When vacuuming dry materials, the folded filter 5
(fig. 2) must be completely dry.
-
During wet vacuuming, the built-in sensor prevents
the maximum filling level in the container from
being exceeded. The device no longer vacuums