MadgeTech Therm-A-lert Product User Manual Download Page 6

Product User Guide

6

1. 

Connect the RFC1000 wireless transceiver (sold separately) to the Windows PC with the 
provided USB cable.

2. 

Additional RFC1000’s can be used as repeaters to transmit over greater distances. If 
transmitting over a distance greater than 500 feet indoors, 2,000 feet outdoors or there are 
walls, obstacles or corners that need to be maneuvered around, set up additional RFC1000’s 
as needed. Plug each one into an electrical outlet in the desired locations.

3. 

To activate the wireless mode, flip the black switch on the back of the Therm•A•lert to the 

'On' position. (0 is 'Off', 1 is 'On'). 

4. 

On the Windows PC, launch the MadgeTech 4 Software. 

5. 

All active data loggers will be listed in the Device tab within the Connected Devices panel, 
showing that the data loggers are recognized. 

6. 

To claim a data logger, select the desired data logger in the list and click the 

Claim

 icon.

7. 

Once the data logger has been claimed, select a start method in the Device tab.

Activating & Deploying the Data Logger

Alarm Settings/Rules in the MadgeTech 4 Software

1. 

To create an alarm rule, select 

Manage Rules

 in the device tab of the software.

2. 

Select 

New

 and enter a Rule name. Enter alarm parameters using the drop down menus and 

selection circles. 

3. 

Select 

OK

 and choose the alarm to enable. The alarm bell is green when enabled and red 

when disabled.

Summary of Contents for Therm-A-lert

Page 1: ...Therm A lert Wireless Temperature Data Logger Product User Guide...

Page 2: ...s 3 Product Overview 4 Software Installation 5 Activating Deploying the Data Logger 6 Channel Programming 7 Product Maintenance 8 RMA Instructions 8 Troubleshooting 9 Compliance Information 10 General...

Page 3: ...are All active MadgeTech data loggers that are within range will automatically appear in the Connected Devices window 5 Select the data logger within the Connected Devices window and click the Claim i...

Page 4: ...er RFC1000 as well as from an RFC1000 to a Therm A lert Obstacles that interfere with or decrease the wireless signal could include but are not limited to building structures such as walls and metal b...

Page 5: ...rs to remotely monitor and manage groups of data loggers throughout a large facility or multiple locations from any internet enabled device Transmit real time data to the MadgeTech Cloud Services plat...

Page 6: ...position 0 is Off 1 is On 4 On the Windows PC launch the MadgeTech 4 Software 5 All active data loggers will be listed in the Device tab within the Connected Devices panel showing that the data logger...

Page 7: ...f the device 3 Change the DIP switches to match the desired channel 4 Return the device wireless mode to ON Channel Programming To configuring the channel settings of the RFC1000 wireless transceiver...

Page 8: ...on on the MadgeTech website 1 Go to www madgetech com rma 2 Sign into your account For new customers select Create an Account 3 Once signed in click on the Make New RMA button 4 Complete the applicabl...

Page 9: ...ess transceiver problems Check that the software properly recognizes the connected RFC1000 wireless transceiver If the wireless data logger is not appearing in the Connected Devices list it may be tha...

Page 10: ...conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l...

Page 11: ...in 55 mm x 133 mm x 33 mm Weight 3 56 oz 101 g Enclosure Material ABS Plastic Approvals US FCC CA IC CE General Specifications Range 20 C to 80 C 4 F to 176 F Resolution 0 01 C 0 018 F Calibrated Acc...

Page 12: ...DOC 1224036 00 REV 7 2016 04 26...

Reviews: