-Prominent
Page 1: ...ADIOTHERAPY MacroMedics BV Oostbaan 670 2841ML Moordrecht The Netherlands 31 0 182 389 777 info macromedics com www macromedics com MANUAL 113000 Instructions for use English Instructions MacroMedics...
Page 2: ...Manual Instructions for use DSPS Prominent SOLUTIONS IN RADIOTHERAPY 2 06042023V4IFU113000 MacroMedics This page is intentionally left blank...
Page 3: ...PY 3 06042023V4IFU113000 MacroMedics Table of Contents 1 Warnings 4 2 MRI Safety Information 4 3 Intended Use Indications for Use 4 4 Baseplate and cradle set up 5 5 Mask set up 5 6 Cleaning Storage a...
Page 4: ...ct before placing it on the patient Do not remove the mask from the patient until the material cools completely Removing the thermoplastic mask before it has set may result in the mask s deformation H...
Page 5: ...e baseplate by means of the supplied quickfacteners 5 Mask set up Follow your department s patient positioning protocol For DSPS treatments there should be approximately one nger width in between the...
Page 6: ...ck frame fall into the designated holes of the cradle 6 Bend both the ends of the frame at shoulder height along the slope of the cradle lock the frame s ends with the rotatable lock pawl that is posi...
Page 7: ...MacroMedics MacroBath 4 or a bath with min internal dimensions in mm 665w x 575d x 80h to heat the mask set the water temperature between 68 C and 70 C 154 4 F and 158 F Leave the mask in the water fo...
Page 8: ...uldroom Tool above the patient s head again to check if the chin still ts underneath it 12 Use both hands to mould the structures of the face like the nose bone orbitae chin and forehead 13 After moul...
Page 9: ...nd shoulder masks 2 Unlock the black sliding lock pawls Place your thumb on top and your index nger at the bottom of the black lock pawl With care gently push a little upwards with your index nger to...
Page 10: ...lvents or abrasive detergents Store the thermoplastic masks in a dry place away from direct sunlight Store the products with the black sliding lock pawls in locked position Dispose of the device in ac...
Page 11: ...ecautions that cannot for a variety of reasons be presented on the medical device itself Prescription Only Devices for sale to physicians or trained healthcare providers only Keep Dry Indicates a medi...
Page 12: ...UTIONS IN RADIOTHERAPY MacroMedics BV Oostbaan 670 2841ML Moordrecht The Netherlands 31 0 182 38 97 77 info macromedics com www macromedics com Visit www macromedics com for a digital copy of this man...