Macnica Mpression 12G-SDI FMC Card Getting Started Download Page 9

12G-SDI FMC Card 

 

Getting Started - 12G-SDI FMC Card 

 

© Macnica, Inc. 

3.

 

Introduction

 

3.1

 

About This Document

 

This manual describes how to use the reference design used by our 12G-SDI FMC Card (hereafter 
FMC card). 

 

3.2

 

Required Hardware and Software

 

 

Hardware 

 

12G-

SDI signal generator (e.g. Blackmagic Design’s Teranex Express)

 

 

Monitor or analyzer that supports 12G-

SDI input (e.g. Blackmagic Design’s SmartView 4K)

 

 

Arria 10 GX FPGA Development Kit (board/AC adapter/micro-USB cable) 

 

BNC cable: 2 

 

FMC card (card/jumper caps 2 pcs.) 

 
Software 

 

Quartus Prime Standard Ver. 16.0 Update 2 (Intel FPGA programming software) 

 

Reference design (You can download the documents and designs from the URL written in the 
Packing list. ) 

 

3.3

 

Related Materials

 

 

Materials provided by Macnica: Title (document number) 

 

12G-SDI FMC Card Schematic (DATA_000070) 

 

12G-SDI FMC Card Reference Manual (DCMT_000331) 

 
Materials from Intel (document number) 

 

Multi Rate Up to 12G SDI II Reference Design for Arria 10 Devices ( AN768 ) 

 

SDI II IP Core User Guide ( UG-01125 )   

 
Materials from Blackmagic Design 

 

Teranex Express Manual 

 

SmartView 4K Manual 

 

Summary of Contents for Mpression 12G-SDI FMC Card

Page 1: ...2017 10 13 2017 Macnica Inc http www m pression com Getting Started 12G SDI FMC Card Revision B 2017 10 13...

Page 2: ...THE POSSIBILITY OF SUCH DAMAGES THE TOTAL CUMULATIVE LIABILITY OF DEVELOPER IN CONNECTION WITH YOUR USE OF THE INFORMATION IN THIS DOCUMENT WHETHER IN CONTRACT OR TORT OR OTHERWISE WILL IN NO EVENT E...

Page 3: ..._________________________________________________________________ 9 3 1 About This Document 9 3 2 Required Hardware and Software 9 3 3 Related Materials 9 4 Overview __________________________________...

Page 4: ...velopment and evaluation This card cannot be used in your mass production products Furthermore when you want to use the card s sample designs for your products please be sure to confirm if it withstan...

Page 5: ...es where the malfunction is caused by the following reasons 1 Misuse abuse of the card or use under abnormal conditions 2 Remodeling or repair 3 A fire earthquake fall or other accidents Figures Some...

Page 6: ...or the equipment in the card to fail or malfunction This may also cause fire Do not put this card or the AC adapter in cooking appliances such as microwave ovens or high pressure containers Doing so m...

Page 7: ...If you have any requests for repairs or technical consultation please contact sales office you purchased or Mpression inquiry URL Keep the card and accessories out of the reach of children Failure to...

Page 8: ...ck Do not clean this card by using a rag containing chemicals such as benzine or thinner Doing so could degrade the card When using a chemically treated cloth comply with its directions and warnings D...

Page 9: ...rd AC adapter micro USB cable BNC cable 2 FMC card card jumper caps 2 pcs Software Quartus Prime Standard Ver 16 0 Update 2 Intel FPGA programming software Reference design You can download the docume...

Page 10: ...4 Overview 4 1 Hardware Configuration Figure 4 1 shows a hardware configuration for implementing a reference design Figure 4 1 Hardware Configuration Monitor that supports 12G SDI input 12G SDI signa...

Page 11: ...Card 11 Macnica Inc 4 1 1 Hardware Design Configuration Figure 4 2 shows the internal configuration of the reference design Figure 4 2 Hardware Design Configuration 12G SDI Monitor e g SmartView 4k 1...

Page 12: ...Arria 10 GX FPGA Development Board 4 Connect the AC adaptor provided to the 12 V DC input J13 5 Set the DIP switches SW3 SW4 SW5 and SW6 on the Arria 10 GX FPGA Development Board as shown in Figure 5...

Page 13: ...developed project and generate a programming file 3 Write the programming file that you generated to the FPGA 4 Press the CPU_RESET push button on the Arria 10 GX FPGA Development Board one time 5 Re...

Page 14: ...RS locked for channel 0 D7 Off CRC error on Chroma Luma for channel 0 D8 D10 RX signal standard for channel0 0 OFF 1 ON SD D8 D9 D10 000 HD D8 D9 D10 001 3Gb D8 D9 D10 010 3Ga D8 D9 D10 011 6Gb D8 D9...

Page 15: ...12G SDI FMC Card Getting Started 12G SDI FMC Card 15 Macnica Inc 7 Document Revision History Date Revision Changes February 2 2017 A First Edition October 13 2017 B Updated design download URL...

Reviews: