Macnaught PR Instruction Manual Download Page 9

  

9

 

 

DIMENSIONS 

2. Cover Screws 

4. LCD Cover  

5. O-Ring 

6. LC Display 

7. Battery 

8. PCB Sensor Board 

9. Polypropylene 
         Housing 

ORDERING CODE 

1. Rubber Boot 

EXPLODED VIEW 

Part Number 

Item Description 

MXD-DS 

Display 

MXS-WMB 

Wall mount bracket 

PR-RMP 

D Wall mount bracket 

SERVICE KITS  

Kit Part Number 

Item Description 

Item Number 

  DR012S 

Battery 

MXS-PCB-RH 

PCB Sensor Board 

MXS-PCB-PR 

PCB Sensor Board 

PP Housing 

MS1279S 

Display Label 

MS685S 

Cable gland - M12 

10 

Cover Screws 

Display Label 

LCD Cover 

O-Ring 

LC Display 

Battery 

MXS-DIS-PR 

 

Wall mount bracket is required for remote installation 

PCB Sensor Board has 1 x Reed switch and 1 x Hall effect 
sensor as standard (unless a special board is requested) 

10. Cable Gland 

3. Display Label 

Summary of Contents for PR

Page 1: ...vides instruction guide on the operation and programming of the Type PR 12mm LCD Digital Register Should you require further assistance please contact you local Macnaught representative Macnaught offe...

Page 2: ...anation of Set up functions 6 Total Batch Total 6 Accumulated Total 6 Flow Rate 6 Meter 6 Programming Set up level 7 Modes of operation 7 Function of buttons 7 Entering and Exiting Setup mode 7 K fact...

Page 3: ...l PR is a microprocessor driven instrument designed to display flow rate total and accumulated total This product has been designed with a focus on Ultra low power consumption to allow long life batte...

Page 4: ...VDC A size type ER17505 Ordering code DR012S Terminal connections Type Terminal strip Wire max 1mm2 Data protection Type Backup of all settings and running totals in flash memory Environment Electrom...

Page 5: ...conscious so the reed switch wires can be connected in any order TERMINAL CONNECTORS 1 Total Batch Total Default value 1 1 Unit L m3 UKGAL USGAL UKbbl USbbl OILbbl L 1 2 Decimals 0 1 2 3 0 2 Accumula...

Page 6: ...and decimal points for flow rate The following decimals can be selected for 0 1 2 and 3 respectively 0000000 111111 1 22222 22 3333 333 3 4 Calculation The flow rate is calculated by measuring the ti...

Page 7: ...presents this mode SETUP mode This mode is to view settings icon on the screen represents this mode SETUP PROG mode This mode is to modify settings icon on the screen represents this mode FUNCTION OF...

Page 8: ...k factor in pulses per gallon PPG it needs to be converted into pulses per LITRE PPL first Divide the PPG k factor by 3 7854 to convert into PPL As an example If the PPG k factor is 136 70 the PPL k f...

Page 9: ...TS Kit Part Number Item Description Item Number DR012S Battery 7 MXS PCB RH PCB Sensor Board 8 MXS PCB PR PCB Sensor Board 8 PP Housing 9 MS1279S Display Label 3 MS685S Cable gland M12 10 Cover Screws...

Page 10: ...ACING THE BATTERY The battery is located on the rear side of LC display item no 6 This can be accessed by removing the rubber boot item no 1 and screws item no 2 After replacing the battery Part no DR...

Page 11: ...xx xx 03 xx xx 5 3 Serial No xxxxxxx xxxxxxx Total Batch Total For your record it is advisable to note down any changes in the parameters PO Reference no Flow Meter model Flow meter Serial NOTES WEEE...

Page 12: ...12 Macnaught Americas 614 South Ware Boulevard Tampa Florida USA 33619 T 1813 628 5506 E info macnaughtusa com W www macnaughtusa com...