TECHNICAL DETAILS
* Use an automatic nozzle and/or filter will reduce flow rate.
These products are positive displacement, rotary vane pumps. Depending on installation and
viscosity, these pumps can deliver up to 20GPM or 76 LPM. Their rugged design makes for a
long life of dependability.
• Inlet: 2” male on tank adapter, 1” female on pump
• Outlet: 1” female
• Built-in bypass valve
• Filter screen
• Thermal overload protection
• Furnished with:
* 14ft/4.2m,3/4”hose for 15GPM/57LPM
* 14ft/4.2m,1”hose for 20GPM/76LPM
* 1pc steel suction pipe
* 1pc manual or Auto nozzle
• Class I Division 1 Group D T4
SAFETY PRECAUTIONS
To ensure safe and efficient operation, it is essential to read and follow each of these warnings
and precautions.
1. DO NOT smoke near pump or use pump near an open flame. Fire could result.
2. Disconnect power to pump before servicing pump.
3. Turn off the switch before connecting power.
4. Take motors needing service to an authorized repair shop or return to factory to maintain.
5. A filter should be used on pump outlet to ensure that no foreign material is transferred to fuel tank.
6. Tank or barrel should be anchored to prevent tipping in both the full and empty conditions.
7. The pump motor is equipped with thermal overload protection. If overheated, it will shut itself off
without any damage to the windings. Move ON/OFF lever to the “OFF” position to reset pump.
WARNING
1. Electrical wiring should be done a licensed electrician in compliance with local codes. Rigid
conduit should be used and proper ground must be provided to avoid the possibility of electrical
shock. Failure to comply with this warning could result in serious injury and/or loss of property.
Use only Static wire, conductive hose when pumping flammable fluids.
2. This product should not be used for fluid transfer into aircraft. This product is not suited for use
with fluids for human consumption or fluids containing water.
3. Extreme operating conditions with working cycles longer than 30 minutes can cause the motor
temperature to rise, thus damaging the motor itself. Each 30-minute working cycle should
always be followed by a 30-minute power-off cooling phase.
4. Use PTFE tape on all pipe threads.
5. MAXIMUM BY-PASSING TIME: 3 MINUTES.
6. DO NOT RUN WITHOUT FLUID.
7. Hot surface-to reduce the risk of burns, do not touch.
8. Disconnect circuit before removing cover and enclosure must be closed tightly when circuits are alive.
9. A seal shall be installed within 50mm of the enclosure.
E1
TECHNICAL
DETAILS
SAFETY
PRECAUTIONS
OPERATION
EXPLODED AND
PARTS LIST
INSTALLATION
MAINTENANCE
LIMITED
WARRANTY
PROBLEMS AND
SOLUTIONS
Item No.
FTP12-001
EXDFP12-001
EXDFP120-001
FTP120-001
Current
DC
DC
AC
AC
Voltage
12V
12V
120V
120V
GPM/LPM
Up to 15/57
Up to 20/76
Up to 15/57
Up to 20/76
Auto
Auto
Auto
Auto
17530572
17530764
17330573
17330762
Pump Model
Electrical Power
Flow Rate
Nozzles