MS574 0210 0007
Page 24
Flowmeter
Type P
NPN, reed-switch
Frequency Minimum 0 Hz - maximum 7 kHz for flowrate.
Maximum frequency depends on signal type and internal low-pass filter.
E.g. Reed switch with low-pass filter: max. frequency 120 Hz.
K-Factor 0.000010 - 9,999,999 with variable decimal position.
Low-pass filter Available for all pulse signals.
Operator functions
Displayed functions
•
total and/or flowrate.
•
total and accumulated total.
•
total can be reset to zero by pressing the CLEAR-key twice.
Total
Digits 7
digits.
Units
L, m3, GAL, USGAL, KG, lb, bbl, no unit.
Decimals
0 - 1 - 2 or 3.
Note
total can be reset to zero.
Accumulated total
Digits
11 digits.
Units / decimals
according to selection for total.
Flowrate
Digits 7
digits.
Units
mL, L, m3, Gallons, KG, Ton, lb, bl, cf, RND, ft3, scf, Nm3, Nl, igal - no units.
Decimals
0 - 1 - 2 or 3.
Time units
/sec - /min - /hr - /day.
INPUTS
OPERATIONAL