background image

 

 

  Sep 1, 2014 

                                                                                                                                                                                                                                       
Version: HW3.819.

 242

SCV1                                                                                                                  Page 

1

 / 

11

     

 
 

Installation Guide 

 

HSL60P6-PC-1-xxx(W/B) 

HSL72P6-PC-1-xxx(W/B) 

HSL60P6-PC-1-xxxE 

HSL72P6-PC-1-xxxE 

HSL60P6-PC-3-xxx(W/B) 

HSL72P6-PC-3-xxx(W/B) 

HSL60P6-PC-3-xxxE 

HSL72P6-PC-3-xxxE 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

    Hanwha SolarOne (Qidong) Co., Ltd. 

  888 Linyang Road, Qidong 

Jiangsu 226200, China 

  www.hanwha-solarone.com 

 

[email protected]

 

 

 
 
 
 
 
 
Note: 1. “xxx” indicates nominal power output 

2. “B” denotes black diamond module 
3. “W” denotes white back sheet and black frame 
4. “E” denotes anti-salted property 

Summary of Contents for HSL60P6-PC-1-xxx

Page 1: ...PC 3 xxx W B HSL72P6 PC 3 xxx W B HSL60P6 PC 3 xxxE HSL72P6 PC 3 xxxE Hanwha SolarOne Qidong Co Ltd 888 Linyang Road Qidong Jiangsu 226200 China www hanwha solarone com sales hanwha solarone com Note...

Page 2: ...STEM DESIGN MOUNTING AND INSTALLATION 5 2 1 System Design 5 2 2 Mechanical Mounting 5 2 3 Module Specification 6 2 4 Mounting Methods For Hanwha SolarOne Modules 6 3 ELECTRICAL INSTALLATION WIRING 8 3...

Page 3: ...ng from improper installation handling or misuse Ensure that the module is used only in applications for which it is suitable see Installing Module All work on a PV system installation setup maintenan...

Page 4: ...of carton box with two or more people 3 Carry modules with proper method in case of module breakage 4 Place the module with proper support do not place one on top of each other Do not insert any elec...

Page 5: ...the local wind and snow loads Ensure that the modules are mounted over a fire resistant roof covering rated for the application To prevent bending vibration mechanical stress or warpage mount the mod...

Page 6: ...ing The module may be clamped only in the permitted clamping areas as indicated on following drawings And the module clamps must not overlap the glass or shade the module surface Recommended tightenin...

Page 7: ...Snow Wind Pressure 5400 4000 Pa Snow Wind Pressure 5400 2400 Pa HSL60 HSL72 HSL60 HSL72 Clamping long frame Clamping short frame Option B Bolting drawing Stainless steel M6 T head bolt Stainless steel...

Page 8: ...condition Only cables with one conductor are to be used Ensure that all materials meet the requirements of the systems maximum voltage current moisture and temperature when they are exposed to sunlig...

Page 9: ...ather and it acts as a barrier that reduces the effectiveness of the grounding connection For an adequate ground the grounding hardware should penetrate the anodized layer For optimal PV system array...

Page 10: ...stalling a module 1 Location with potential for extreme sand and dust damage 2 Location with extreme air pollution chemical vapors acid rain and or soot etc 3 Location with extreme hail and or snow 4...

Page 11: ...USA Hanwha SolarOne Australia 1901 Newport Boulevard Suite 350 Sydney Australia Costa Mesa CA 92627 Tel 61 405 717 848 402 Highland Avenue Suite 1B Fax 61 249 329 057 Cheshire CT 06410 Tel 1 203 250 3...

Reviews: