16m which fits for large room. Time-Delay is added continually: When it receives the
second induction signals within the first induction, it will restart to time from the
moment.
Time–Delay is adjustable. It can be set according to the consumer’s desire. The
minimum time is 10sec±3sec. The maximum is 12min±1min.
NOTE:
the high-frequency output of the HF sensor is <0.2Mw- that is just one 5000th of
the transmission power of a mobile phone or the output of a microwave oven, the baby
can't touch it.
INSTALLATION:
(see the diagram)
Switch off the power. Connecting the power and the load to sensor as per the
connection-wire sketch diagram. Switch on the power and test it
CONNECTION-WIRE DIAGRAM:
(look at illustration)
TEST:
Turn the TIME knob anti-clockwise on the minimum (10s). Turn the SENS knob
clockwise on the maximum (+). Turn the LUX knob clockwise on the maximum (sun).
When you switch on the power, the light will be on at once. And 10sec±3sec later the
light will be off automatically. Then if the sensor receives induction signal again, it can
work normally. When the sensor receives the second induction signals within the first
induction, it will restart to time from the moment.
Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is less than 3LUX
(darkness), the inductor load could work when it receives induction signal.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the
sensor lamp could not work!
NOTES:
Electrician or experienced human can install it.
Can not be installed on the uneven and shaky surface
In front of the sensor there shouldn’t be obstructive object affecting detection.
Avoid installing it near the metal and glass which may affect the sensor.
For your safety, please don’t open the case if you find hitch after installation.
In order to avoid the unexpected damage of product, please add a safe device of current
6A when installing microwave sensor, for example, fuse, safe tube etc.
SOME PROBLEM AND SOLVED WAY
:
The load don’t work:
a. Check the power and the load.
b. Whether the indicator light is turned on after sensing? If yes, please check load.
c. If the indicator light is not on after sensing, please check if the working light
corresponds to the ambient light.
d. Please check if the working voltage corresponds to the power source.
The sensitivity is poor:
a. Please check if in front of the sensor there shouldn’t be obstructive object that affect
to receive the signals.
b. Please check if the signal source is in the detection fields.
c. Please check the installation height.
The sensor can’t shut automatically the load:
a. If there are continual signals in the detection fields.
b. If the time delay is set to the longest.
MCE137
PL
Mikrofalowy czujnik ruchu
Mikrofalowe czujniki ruchu są aktywnymi detektorami ruchu pracującymi na
częstotliwości 5.8 GHz Urządzenia cechują się wysoką częstotliwością pracy, niewielką
emisją mocy (< 0.2 mW) i bardzo dobrą detekcją ruchu w stronę do lub od czujnika
ruchu. Czujnik ST700C posiada wbudowany czujnik zmierzchowy. Specyfika urządzenia
pozwala na instalację za drzwiami, panelami, elementami szklanymi lub cienkimi
ściankami. Prezentowane właściwości pozwalają na wszechstronne zastosowanie
mikrofalowego czujnika ruchu.
INFORMACJE TECHNICZNE:
Napięcie zasilania: 110-240V/AC
Częstotliwość zasilania: 50Hz
Zasięg detekcji (promień): 4-10m (<24°C)
Czujnik oświetlenia: 3-2000LUX (regulowany)
Czas załączenia: min10s±3s, max12min±60sec
CECHY:
Czujnik oświetlenia w zależności od potrzeby może zostać regulowany: pozycja
SŁOŃCE (max) –praca w dzień i nocy, KSIĘŻYC –praca w nocy przy poziome natężenia
rzędu ok. 3LUX.
- Może zostać skalibrowany do potrzeb położenia – zasięg wykrywania od minimum
2m , do aż 16m, tak aby urządzenie sprawdzało się w korytarzach.
- Regulacja czasu załączenia: w zależności od potrzeby może zostać ustawiona w
zakresie od 10s±3s do 15 min±2min. Timer jest resetowany za każdym razem kiedy
urządzenie wykryje ruch.
- Regulowany czas wyłączenia w przedziale 10 sec(+/-3 sec)do maksymalnego 12 min
(+/-1min)
INFORMACJA:
Wysoka częstotliwość wysyłana przez czujnik ma moc <0.2mW, czyli
około 0.02% mocy emitowanej przez telefon komórkowy lub kuchenkę mikrofalową.
MONTAŻ:
(zobacz ilustracja)
Pole detekcji: 360º
Częstotliwość pracy: 5.8 GHz
Zalecana wys. montażu: max: 4-15m
Prędkość detekcji ruchu: 0.6~1.5m/s
Pobór energii: 0.9W
Przenoszenie energii: <0.2mW
Maksymalne obciążenie:
1200W (220-240V/AC)
800W (110-130V/AC)
300W (220-240V/AC)
200W (110-130V/AC)