Step 1 – Make all desired power, audio out, configuration switch
and I/O connections to the unit and power up. Unit will
initiate self test and default to idle mode.
Step 2 – Provide a momentary or maintained contact closure
between the message input(Connector 1, terminals 2-
9) desired and common(Connector 1, terminal 1).
Message Number Display will show the message
number during playback.
Step 3 – Provide a momentary contact closure to the stop
input(Connector 1, terminal 10) to stop playback and
return to idle mode - or - allow message to play to end
at which point, system will return to idle mode.
MacFi-mp will ignore an input which corresponds to an empty or
corrupt message location. Play relay contact will be maintained
for the duration of play sequence. When playing multiple
messages through queued messages or via maintained start
activation’s, the system will drop the play relay for approximately
100mS between sequences.
3.5 Memory
Clear/Test
Use this procedure when you wish to clear system memory of
previously recorded messages or test/verify system memory for
bad blocks.
Step 1 – Remove power from MacFi-mp
Step 2 – Depress and hold Record Setup button while restoring
power to MacFi-mp. Continue to hold Record Setup
button until Record Indicator remains ON, at which
time it may be released. Record Indicator will remain
ON and Status Display will read FC while system runs
audio memory check. This process could take up to 20
minutes on the MacFi-mp 40
Step 3 – Wait until Record Indicator turns off, indicating memory
check is complete, and unit will perform as usual.
-or-
Remove then re-apply power to bypass memory test.
3.6 Erase
Message
Individual message locations may be erased by simply
recording a message to that location with less than 1 second in
duration. This short recording will instruct the system to erase
the data from that message location.