background image

Smart photometry

NANOCOLOR

®

 VIS II 

NANOCOLOR

®

 

UV

/

VIS

 II 

Quickstart guide

MACHEREY-NAGEL GmbH & Co. KG · Neumann-Neander-Str. 6–8 · 52355 Düren · Germany

France:

MACHEREY-NAGEL EURL

Tel.:  +33 388 68 22 68

Fax:  +33 388 51 76 88

E-mail: [email protected]

Switzerland:

MACHEREY-NAGEL AG

Tel.:  +41 62 388 55 00

Fax:  +41 62 388 55 05

E-mail: [email protected]

Germany

and international:

Tel.:  +49 24 21 969-0

Fax:  +49 24 21 969-199

E-mail: [email protected]

MACHEREY-NAGEL

EN ISO 9001: 2008

CERTIFIED

MACHEREY-NAGEL GmbH & Co. KG · Neumann-Neander-Str. 6–8 · 52355 Düren · Germany

France:

MACHEREY-NAGEL EURL

Tel.:  +33 388 68 22 68

Fax:  +33 388 51 76 88

E-mail: [email protected]

Switzerland:

MACHEREY-NAGEL AG

Tel.:  +41 62 388 55 00

Fax:  +41 62 388 55 05

E-mail: [email protected]

Germany

and international:

Tel.:  +49 24 21 969-0

Fax:  +49 24 21 969-199

E-mail: [email protected]

MACHEREY-NAGEL

EN ISO 9001: 2008

CERTIFIED

Distributed By:

Summary of Contents for NANOCOLOR UV/VIS II

Page 1: ...Smart photometry NANOCOLOR VIS II NANOCOLOR UV VIS II Quickstart guide Distributed By ...

Page 2: ......

Page 3: ...Set up location 10 3 2 Package content 10 4 Outer appearance 11 4 1 Front and side view 11 4 2 Back view 12 5 Operating instruction 13 5 1 Connectivity 13 5 2 Turning on the instrument 13 5 3 Operation and user guidance 14 6 Methods 19 6 1 Basic functions 19 6 2 MN tests 23 6 3 Scan 25 6 4 Color measurements 26 6 5 Test number 27 7 Data memory 28 7 1 Measurement memory 29 7 2 IQC memory 30 7 3 Bac...

Page 4: ......

Page 5: ... comfortable and enjoyable handling of the spectrophotometer Thus the spectrophotometer is the ideal laboratory photometer for the entire spectrum of water analysis 1 1 Technical description A halogen lamp and a deuterium lamp cover the wavelength range from 190 1100 nm in the NANOCOLOR UV VIS II A halogen lamp covers the wavelength range from 320 1100 nm in the NANOCOLOR VIS II The light of the r...

Page 6: ...s More than 200 preprogrammed tests and special methods 100 user defined methods absorbance transmission factor kinetics 2 point calibration scan nephelometric turbidity measurement Turbidity measurement Nephelometric turbidity measurement 0 1 1000 NTU Cuvette slot Test tubes 16 mm OD Rectangular cuvettes 2 mm 10 mm 20 mm 40 mm and 50 mm Data memory 16 GB Micro SDHC card 5000 measured data sets sp...

Page 7: ... W H 400 440 170 mm 360 400 110 mm Weight 6 5 kg 4 0 kg Warranty 2 years Housing protection type IP20 Protection rating class 1 class 3 Declaration of conformity EMC directive 2014 30 EU EN 61326 1 2006 LVD directive 2014 35 EU EN 61010 1 2010 EN 61010 2 81 2002 A1 2003 EN 60529 IP20 ...

Page 8: ... power cable or power adapter only 2 2 Biological risk When using the instrument it may be necessary to handle hazardous chemicals or biologically harmful samples Please adhere to the following guidelines while using the instrument Please read all information concerning hazards and safety measures in the material safety data sheets and on the packages you work with All utilized compounds need to b...

Page 9: ...R UV VIS II features a halogen and a deuterium lamp The NANOCOLOR VIS II features a halogen lamp Both get very hot during opera tion Hence there is a risk of severe burns Before exchanging the lamps let them cool down for at least 30 minutes Please disconnect the instrument from the power source before starting any maintenance work in order to avoid electric shock The deuterium lamp of NANOCOLOR U...

Page 10: ...ure not to damage its contents Remove the instrument and all other parts carefully Check the package inst rument and accessories for visible damages In case a part is damaged please contact your distributor or MACHEREY NAGEL s technical support see 8 5 Contact p 32 The following list contains all items inside the package Please ensure that your ship ment is complete In case of missing items please...

Page 11: ...2 Side view UV VIS II a a b c e Fig 3 Front view VIS II f Fig 4 Side view VIS II a Stereo speakers b 10 1 HD touch screen with PCAP c Universal cuvette slot for tube tests of 16 mm OD and rectangular cuvettes of 2 mm 10 mm 20 mm 40 mm and 50 mm d Lamp compartment with halogen and deuterium lamp SDHC card slot e 2D bar code scanner f USB A interface ...

Page 12: ...5 Back view UV VIS II 7 1 2 3 4 8 6 Fig 6 Back view VIS II 1 USB A interface 2 USB B interface 3 Ethernet LAN interface 4 RS 232 interface 5 Connection for power supply 110 240 V 50 60 Hz 6 Main switch 7 SDHC card slot UV VIS II refer to Fig 1d 8 Connection for power supply 12 V DC 3A ...

Page 13: ...ll as laboratory infor mation management systems LIMS Next to the electrical connection Fig 6 8 5 more types of interfaces are available within the NANOCOLOR VIS II as indicated on page 10 1 x SDHC card slot Fig 6 7 2 x USB Host Fig 6 1 and Fig 4 f 1 x USB function Fig 6 2 1 x Ethernet LAN Fig 6 3 1 x RS 232 Fig 6 4 for the connection of different devices as well as laboratory infor mation managem...

Page 14: ...meter features a 10 1 HD display with a projective capacitive touch screen PCAP The instrument s cover glass is non reflecting It can be easily and conveniently cleaned with the microfiber cloth included in your package or with a soft cotton cloth UV VIS II Open Mode 28 10 2014 10 57 Fig 7 Start screen ...

Page 15: ... for projective capacitive touch screens Wearing protective gloves does not impair handling the instrument properly In selected menus you can zoom in and out by moving two fingers in opposite directions or towards each other Numbers or texts can be inserted to the respective number or text fields by touching the respective field which automatically opens a pop up displaying a text and numeric keyp...

Page 16: ...functions Home icon By pressing this icon at any position in the menu one is guided back to the start screen see Fig 7 Start screen p 14 From the start screen it is not possi ble to get back to the last application via the icon Back icon By pressing this icon one goes back to the application or level that was used last Please consider that some menus cannot be retrieved by pressing the icon e g me...

Page 17: ...ving it out of the blue colored area UV VIS II Open Mode 28 10 2014 10 57 Fig 12 Editing the favorites bar 5 3 4 Option buttons and check boxes Option buttons are framed in black Activated option buttons are filled with a black dot Please consider that only one selection point can be activated at a time You can activate a selection point by touching it By leaving the menu the selected options will...

Page 18: ...lace Printer Sound Memory Settings Date Time Region Language Select region AR Argentina AT Österreich AU Australia BE Belgique BE België BG БЪԓгариЯ Fig 13 Predefined list UV VIS II Open Mode 28 10 201 0 0 0 0 Standard Measurement OK Standard Method Submethod Cuvette Setpoint Margin Standard LOT Test LOT Select standard 0 04 Ammonium 10 REF 925 011 0 05 Ammonium 50 REF 925 012 0 06 Ammonium 200 RE...

Page 19: ...cation of an absorbance with a user defined factor After having selected this method a window will appear asking for the factor and the wavelength for the measurement and calculation Confirming with opens the measurement window Inserting the zero solution and pressing will initiate the zero measurement After the successful measurement of the zero solution the sample solution needs to be inserted P...

Page 20: ...irming the entries by pressing will open the measurement window Inserting the zero solution and pressing will initiate the zero measurement Then the standard solution needs to be inserted Pressing will start the sample measurement After the standard solution the sample solution has to be inserted Pressing will start the sample measurement After the measurement has been completed the mea surement r...

Page 21: ...rement of the zero solution the sample solution need to be inserted Pressing will start the measurement process After the measurement has been completed the measurement result is displayed in the result window It is possible to perform more than one measurement in a row The results are then listed in a list on the left side of the result window Detailed information for each measurement can be call...

Page 22: ...e zero solution and pressing initiates the zero measurement After the successful measurement of the zero solution the sample solution needs to be inserted Pressing starts the measurement process After the measurement has been completed the measurement result will be displayed in the measurement window It is possible to perform more than one measurement in a row The results are then listed in a lis...

Page 23: ...nd the icons below the result window different sample information can be added Removal of the cuvette or leaving the menu via the remainder of the task bar icons quits the measurement process and stores the measurement result in the measurement memory of the device UV VIS II Open Mode 28 10 2014 10 57 Measure Zero 0010 Sample author Sample place Comment 49 mg L Mg 86 mg L Ca 25 e 29 2 0444 Hardnes...

Page 24: ...uest for a zero solution will appear After insertion of the rectangle cuvette the measurement is initiated by pressing After the successful measurement of the zero solution the sample solution needs to be inserted Pressing starts the measurement process After the measurement has been completed the measurement result will be displayed in the result window Via and the icons below the result window d...

Page 25: ...ent process A graphic depicting the wavelengths will appear The scan of the whole wavelength range can be observed live After the measurement has been completed the complete scan will be displayed in the result window Via and the icons below the result window different sample information can be added The scan title can be edited via the function Edit title accessible via the icon Removal of the cu...

Page 26: ...or type to be measured the field light source and observer are automatically filled in These can always be manually changed In this case however the selection of the color number automatically indicates the preference CIE L a b Con firming with opens the measurement window After measurement of the zero solution and the color sample the result will by displayed in the result window To analyze the c...

Page 27: ...mber can be inserted via the numeric keypad for example insert 044 for the NANOCOLOR Hardness Ca Mg test If the number is correct information about the test will appear on the display Confirming with will open the measurement window Dependent on the method the sample can now be measured directly or against a zero solution UV VIS II Open Mode 28 10 2014 10 57 0 7 4 1 C 8 5 2 9 6 3 Test Number OK 04...

Page 28: ...ed on the factory in stalled 16 GB micro SDHC card Furthermore a data backup can be performed through the menu option In this case internal data are saved on the SDHC card UV VIS II Open Mode 28 10 2014 10 57 M 10 Sept 1 x 1 x Settings Power saving mode Dilution Format Backup Sipper NTU Check Lamp Settings Reaction Time Remember Sample Place Printer Sound Memory Settings Date Time Region Language ...

Page 29: ...surement Type Sample Number Begin Date End date Method User Location Type Author Operator Fig 22 Measurement memory Measurement results can be printed selected or exported as csv file The memory menu assists with the selection according to different sample information dates and measurement methods This selection can also be printed or exported If more than one measuring result is printed the hardc...

Page 30: ...ged as IQC measurements The IQC menu can be entered by pressing Sub sequent selection of opens the IQC memory The results saved in this memory pro vide amongst others the basis for the IQC control charts It is possible to print export or select data of the IQC memory just as those of the measurement memory For inspection of detailed information the same rules apply for the IQC memory as for the me...

Page 31: ... SDHC card or a connected USB drive Additionally one can recover an existing backup from the SDHC card Please note that in case of recovering an existing backup the complete instrument storage will be overwritten and all unsaved data will be erased UV VIS II Open Mode 28 10 2014 10 57 M 10 Sept 1 x 1 x Settings Power saving mode Dilution Format Backup Sipper NTU Check Lamp Settings Reaction Time R...

Page 32: ... local and national legal regulations EU Directive 2012 19 EU MACHEREY NAGEL disposes old instruments free of charge Note Disposal using public waste disposal facilities is not permitted In case of disposal please contact your MACHEREY NAGEL representative 8 4 Cleaning the instrument The instrument s housing can be cleaned with a wet cloth Splashes and spillings need to be immediately removed from...

Page 33: ...ficates and Material Safety Data Sheets Customized special products Easy ordering and short delivery times Large number of catalogs flyer and product information of course free of charge Contact Technical support and customer service Filtration Rapid Tests Water Analysis 49 24 21 969 332 csc mn net com MACHEREY NAGEL GmbH Co KG Neumann Neander Str 6 8 52355 Düren Germany France MACHEREY NAGEL EURL...