User Guide HC - Copyright © 2008 MAC3. All right reserved.
Man 01 Disegno 6328
33
Via Baldanzese, 149 50041 Calenzano FI
Tel. 055 8877672 – Fax 8877068
www.mac3.it - e-mail: [email protected]
English
Pressing ENTER, the value is saved in memory.
Keep pressed ENTER till it will be displayed
“Done.…………”
and then it passes automatically to:
Sector3 Pressure
2.50 Bar
Pressing ENTER, the value is saved in memory.
Keep pressed ENTER till it will be displayed
“Done.…………”
and then it passes automatically to:
Press + or – to change the value
(from 1.00 to 7.50)
insert the value for irrigation sectors at the third pressure set
point.
Sector4 Pressure
3.00 Bar
Pressing ENTER, the value is saved in memory.
Keep pressed ENTER till it will be displayed
“Done.…………”
and then it passes automatically to:
Press + or – to change the value
(from 1.00 to 7.50)
insert the value for irrigation sectors at the fourth pressure
set point.
If Garden Mode = OFF
it passes automatically to:
System Pressure
4.00 Bar
Pressing ENTER, the value is saved in memory.
Keep pressed ENTER till it will be displayed
“Done.…………”
and then it passes automatically to:
Press + or – to change the value
(from 1.00 to 7.50)
insert the value for desired pressure of the system
.
Pressing ENTER, the value is saved in memory.
Keep pressed ENTER till it will be displayed
“Done.…………”
and then it passes automatically to:
System Start
ON
Press + or – to change the value (ON/OFF)
You must set ON to active the pump.
WARNINGS: if it is set “ON” HydroController
immediately powers the electro-pump!
Press ENTER to save all the parameters in permanent
memory.
Keep pressed ENTER till it will be displayed
“Saving Param.…………” followed by
“Done.…………”
and then it passes automatically to:
Save & Exit
With ENTER
X.X Bar MASTER
Yyyyyyyyyyyyyy
This is the standard visualization of the display for
hydrocontroller set as MASTER:
-X.X Bar is the pressure value in the system
- yyyyyyyyyyyyyy is one of the messages defined in
paragraph 5.1