www.mac-srl.it
34
00_Manutenzione-05 200203
GBR
FAQ
N°
INCONVENIENCES
POSSIBLE CAUSES
HYPOTHESIS BREAKDOWN
SOLUTIONS
1
THE BOLLARD DOESN’T GO UP
(presence of air in the circuit)
Low oil level in the tank
damaged seals
Replace the seals
Add oil
Manual unlock is open
Manual unlock is open
Close the manual unlock
electric valves are open
electric valves are open or damaged
Check electric valve voltage coil
electric safe es are open
electric safe es are open or damaged Fix / replace electric safe es
(photocells, sensi ve head, magne c
coils, emergency bu on, clock)
Oil leaks
Break of the hydraulic circuit
Fix the circuit
Incorrect sense of rota on
Incorrect limit switch connec on
Re-wire up magne c limit switch
Reversed limit switches
Incorrect electric engine connec on
Re-wire up the electric engine on the
electronic programmer
Missing power source
switch turned on
Re-ac vate the disconnector bu on
Faulty electronic programmer
Replace the electronic programmer
Faulty fuses
High absorp on peak
Replace the fuse with another
suitable
Low poten al diff erence
Short-circuits on the line
Check and fi x the breakdown
Engine, electric valve inputs, output
24Vac, traffi c light
2
IRREGULAR BOLLARD ASCENT
(pump in fault of fl ow)
Pump not completely immersed in
the oil
Blocked aspira on or not immersed in
the oil
Check the oil level
Air bubbles in the circuit
Faulty aspira on
Check the oil cleaning
dirty oil
Oil with many work hours
Replace the oil
Oil with solid bodies in it
Manual unlock is open
See point 1
See point 1
electric valves are open
Electrical valve broken
Replace the electrical valve
Mechanic fl aw
Low voltage
small cable section
Replace the cable
Maneuver a er opening the manual
unlock
Air aspira on in the pump
The problem disappears with a
second opera on
3
SLOW BOLLARD ASCENT
(insuffi cient pressure)
(s cky oil at room temperature)
Incorrect maximum pressure
Correctly calibrate the valve
consul ng “regula on of the bollard
rising force”
Air presence in the circuit (the bollard
doesn’t go up)
See point 1
See point 1
Pump failing in payload
Worn pump
(Irregular bollard ascent)
See point 2
See point 2
Too viscous oil
Very compact oil
Replace the oil type
Too liquid oil
Too high temperature
Replace the oil
Excessive leaks/ breaks in the circuit
Circuit leaks
Check the circuit
Break of the O-Ring in the control unit
runner
Replace the O-Ring where required
Incorrect supply voltage
Faulty electric programmer
Sequen al programming for the
mul ple ascent of the bollards in the
electrical programmer
Not ghtened screws
ghten screws
Low fuse voltage
Check power cable
problem with the distributor
Check with the distributor
Insuffi cient condenser
broken condenser
Replace condenser or augment it
too li le condenser
Fric on guide rails
too ghten guide rails
“regula ons of bollard guide rails”
4
CLOSE BOLLARD DOESN’T GO
DOWN
Insuffi cient condenser
See point 3
See point 3
Cylinder high pressure at the limit
switch
Too tense pressure valves
Correctly calibrate the valve
consul ng “regula on of the bollard
rising force”
Summary of Contents for C275A
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 37: ...info mac srl it 37 00_Manutenzione 05 200203 GBR...
Page 38: ...www mac srl it 38 00_Manutenzione 05 200203 GBR...
Page 39: ...info mac srl it 39 00_Manutenzione 05 200203 GBR...
Page 40: ...www mac srl it 40 00_Manutenzione 05 200203 GBR...