INSTRUCTION MANUAL

Read and understand all of the instructions and safety information in 

this manual before operating this product.

MAN-009 Rev D

            03/2019

© 2019 MAC Medical, Inc.

ES Series Surgical Scrub Sinks

Installation - Operation - Maintenance - Cleaning

OSHPD

Pre-Approved

E25 Model

E47 Model

E76 Model

C

Summary of Contents for ES Series

Page 1: ... instructions and safety information in this manual before operating this product MAN 009 Rev D 03 2019 2019 MAC Medical Inc ES Series Surgical Scrub Sinks Installation Operation Maintenance Cleaning OSHPD Pre Approved E25 Model E47 Model E76 Model C ...

Page 2: ...structions 5 Installation 7 Recommended Mounting Specifications and Water Supply Locations Single Basin 8 Recommended Mounting Specifications and Water Supply Locations Double Basin 9 Recommended Mounting Specifications and Water Supply Locations Triple Basin 10 Installing and Operating the Soap Spout 11 Connect Drain Pipe to Drain and Plumbing to Water Lines 12 Plumbing Install Instructions 12 Ad...

Page 3: ... with this equipment The use of inexperienced unqualified persons to service the equipment or the installation of unauthorized parts could cause serious personal injury or result in costly damage Always unplug power cord from power source prior to attempting any repairs or servicing WARNING Burn Hazard DO NOT CHANGE temperature settings on thermostatic mixing valve unless you are a trained mechani...

Page 4: ...essure regulators or other means that maximum specified pressures are not exceeded to ensure that water supplies are properly protected for internal cross connection control in accordance with local building and plumbing requirements to eliminate water hammer conditions should they occur in the service piping 4 Power requirements for sinks with infrared sensor operations a 120 Volt 60 Hz single ph...

Page 5: ...id damage Do not drop tools on the sink or scratch the surfaces with sharp edges Caution Do not use a box cutter or any other cutting utensil to remove the plastic wrapping around the sink These items can scratch the protective coating on the stainless steel allowing the surface to rust IMPORTANT Wear gloves and eyewear during the unpacking operation Retain all shipping materials until the sink is...

Page 6: ...ar Fig 4 Z Bar and zip ties 9 Remove the Sink Hardware boxes from their locations and lift the sink off of the wooden skid The Ecomony Sink is now ready for installation 10 Discard shipping and packing materials in compliance with state and local regulations 11 When not in use sinks must not be double stacked while in storage While still on their shipping crates sinks must not be double stacked wh...

Page 7: ...Attach the Z bracket s to the wall Recommended mounting specifications shown on page 8 page 9 and page 10 B IMPORTANT For wall mounted units the wall structure must be capable of supporting the load 4 Install the soap spout on the sink See page 11 5 Mount the sink body to the Z Brackets attached to the wall A With the help of an assistant slide the sink over the Z bracket s until it locks securely...

Page 8: ...K CW 2X HOLE IN BRACKET 7 14mm 14 23 64 136 78mm 5 25 64 9 32 364 87mm 406 40mm Z BRACKETS 203 20mm 8 BOTH 16 91 24mm 4 13 16 122 24mm 330 20mm 13 75 28mm 3 19 32 2 31 32 25 635mm 41 1 2 Z BRACKET 1054 13mm HEIGHT 723 93mm HEIGHT LOWER Z BRACKET 28 1 2 SUPPLIED WITH SINK 6 TAIL PIECE FINISHED FLOOR TYPICAL UTILITY CONNECTION POINT HW DR CW 19 3 4 501 65mm 100 06mm 3 15 16 16 29 32 15 16 429 71mm 2...

Page 9: ...ght 1054 22mm 28 1 2 724 02mm 8X 9 32 Hole in Bracket 7 14mm 47 1193 80mm HW CW DR HW CW DR 19 3 4 501 65mm 4 1 64 101 98mm 16 15 16 429 83mm 23 9 16 598 73mm 13 1 2 342 90mm DRAIN C L 6 TAIL PIECE SUPPLIED WITH SINK FINISH FLOOR Typical Utility Connection Point HW DR CW 16 23 32 424 59mm Broken Out Sections Show Z Brackets Supplied with Sink 21 27 32 554 99mm 21 27 32 554 99mm 4 13 16 122 24mm 8 ...

Page 10: ... 93mm 171 45mm 4 6 3 3 3X 19 91 24mm 32 428 74mm 7 16 4 101 98mm 8 598 73mm 23 9 16 FINISH FLOOR 501 65mm 3 14 4 HW CW DR HW CW DR 1054 22mm 41 1 2 724 02mm 28 1 2 342 90mm 1 13 2 HW DR 424 59mm 16 32 23 25 32 644 93mm 13 13 25 32 644 93mm WALL SURFACE 1 64 Broken Out Sections Show Z Brackets supplied with Sink Upper Z Bracket Height Lower Z Bracket Height Typical Utility Connector Point HW DR CW ...

Page 11: ...pout item 1 through the small hole at the top of the sink Fig 8 The nut item 2 should rest on top of the sink 3 Re install the bushing onto the spout from inside the cabinet Fig 9 4 Attach the soap tubing to the spout and soap pump circled in red as shown in Fig 10 and Fig 11 To Operate the Soap Pump press the soap spout down repeatedly to start the flow of the soap Fig 7 Soap Spout with nut and b...

Page 12: ...rials with a construction capable of withstanding the high limit output temperatures of the water heating source Need for Periodic Inspection and Yearly Maintenance Periodic inspection and yearly maintenance by a licensed contractor is required Corrosive water conditions temperatures over 200 F unauthorized adjustments or repair could render the valve ineffective for service intended Regular check...

Page 13: ...rential between hot cold water supplies must be less then 25 Troubleshooting Plumbing Fluctuating or erratic hot water temperature at fixture Unbalanced Pressure Install balancing or throttling valve at the hot and cold water supplies and adjust accordingly for demand Hot water backing up into cold water line Hot water pressure is higher than cold water pressure Examine check valves for dirt debri...

Page 14: ...rared activated plumbing SS0132 01 2 1 2 Balance Flow Control Valve S0024 2 Solenoid Valve for Infrared S0013 3 Knee Operated Water Valve S0029 3 Infrared Sensor S0012 4 Thermostatic Mixing Valve for both knee operated or infrared activated plumbing S0104 5 Swivel Aerator for both knee operated or infrared activated plumbing S0032 6 Soap Spout for both knee operated or infrared activated plumbing ...

Page 15: ...ortant Do not interrupt the sensor beam until the light turns off Operation The sensors are pre set and equipped with a logic board The sensors determines the range during initialization period The time after initial power until the light turns off is approximately 5 minutes The range is approximately 12 14 in front of the sensor and is 25 degrees at peak During the initialization period the senso...

Page 16: ...ST KT can be purchased and installed on economy sinks The installation would require some alteration in the plumbing configuration The installation instructions are covered in our MAN 028 which is available on our website http macmedical com under Resources Technical Publications Manuals Fig 17 Sink Timer Kit ...

Page 17: ...ing pads Soft bristle brush Mild detergents Sodium Bicarbonate baking soda Distilled water pH rating 7 alone or with a mild detergent White vinegar in a spray bottle Isopropyl Alcohol Hospital grade non bleach disinfectants Cleaners approved for use on stainless steel Cleaning Stainless Steel Surfaces 1 Using a damp lint free cloth and approved cleaner wipe down the entire exterior surface of the ...

Page 18: ...factory It is the customer s responsibility to inspect the product for packaging damage before signing the BOL This warranty does not apply to products which have been subject to abuse misuse accident modification alteration tampering negligence lack of routine maintenance or misapplication or products that have been repaired by other than MAC Medical or its authorized representatives This warrant...