10

9

06

Adjusting to correct ceiling height:

Refer to step 9, 10 and 11 from 

assembly instructions for detail on 

adjusting the length of the ladder.

WARNING: DO NOT SHORTEN THE 

LADDER TOO MUCH.

 If the ladder is 

too short, it may unexpectedly fold up 

during use, thus risking serious personal 

injury. To check that the ladder is the 

correct length, unfold it to its full length. 

All sections of the ladder must be 

aligned perfectly with no gaps, and both 

strings must rest flat on the floor (see 

figure 8).
DO NOT use the ladder if all sections of the ladder are not aligned. If the ladder is too long, shorten the 

strings once more. If the ladder is too short, order a new lower section from your dealer. Do NOT allow the 

ladder to rest on a box, blocks, platform or similar. Such constructions are unsafe and unstable, and do not 

provide appropriate permanent support for the ladder.

07

How to use the ladder:

The following drawings show how to use the loft ladder safely (see figure 9).

NOTE: 

If your building construction differs from installation guide above, consult an expert.

WARNING

: Never modify the product. The manufacturer accepts no liability whatsoever for personal injury 

or damage caused to the building or parts thereof by a product, whose construction has been modified.

Figure 9A

Figure 9B

Figure 9C

Figure 7

Figure 8

PN115998-01 Macallister_LL2T_Loft_Ladder_Instruction_Manual_A5_Rev0618_V2.indd   9

22/06/2018   14:03

10

9

Safety & Operation

Use

01

 Repair & Maintenance

• 

Repairs and maintenance shall be carried out by a competent person and be in accordance with these 

instructions. 

NOTE:

 A competent person is someone who has the skills to carry out repairs or maintenance, 

eg. trained by the manufacturer.

• 

For repair and replacement of parts, e.g. feet, springs and hooks, contact your supplier or distributor.

• 

Ladders shall always be operated in accordance with the producer's instructions.

• 

Timber loft ladder stiles and treads should not be painted or varnished.

• 

Periodically lubricate all moving parts with light oil.

• 

Periodically clean all timber parts to prevent the build-up of dirt, grease and other contaminants.

02

 Traceability

For traceability purpose it can be identified by the barcode (EAN) number and also manufacturing date or serial 

number, these can be found on the trapdoor.

Care & Maintenance

• 

Never use this loft ladder for purposes for which it has not been designed, such as trade or building work.

• 

Never use this product unless it has been fully, and correctly, installed.

• 

Fully open trapdoor before unfolding the ladder.

• 

Ensure the springs and connecting wires have not become trapped or snagged.

• 

Ensure the springs and connecting wires are correctly positioned and are secure.

• 

Fully unfold ladder before use.

• 

Ensure any catches or locks are fully engaged before ascending the ladder.

• 

Ensure both ladder feet rest firmly on the floor before climbing the ladder.

Inspect the ladder before climbing (see above) – do not use if damaged.

Only wear suitable footwear whenever ascending or descending the ladder.

Maintain 3 points of contact by gripping the handrail or ladder stiles when ascending or descending.

Do not overload the ladder by carrying heavy objects.

Take care when carrying awkward shaped objects up and down the ladder.

Keep a firm grip on anything being carried to prevent the object falling.

Only ascend and descend the ladder by facing the treads.

Never exit the ladder by stepping away from the treads.

Ensure the trapdoor is securely locked after use.

Pre-Use and periodic checks: 

• 

Check stiles and treads are not split, warped, bowed, loose, rotten or otherwise damaged.

• 

Check all screws, bolts and nuts are secure and tight (do not overtighten).

• 

Check trapdoor locks into position correctly.

• 

Check metal parts are not corroded or otherwise damaged.

• 

Check all hinges operate smoothly (lubricate periodically – see label on trapdoor).

• 

Check ladder sections operate smoothly when opened.

• 

Check ladder sections are straight when fully opened.

• 

Check ladder feet rest firmly on the floor.

• 

Check ladder sections are flat and correctly positioned once folded.

PN115998-01 Macallister_LL2T_Loft_Ladder_Instruction_Manual_A5_Rev0618_V2.indd   10

22/06/2018   14:03

PN115998-01 Macallister_LL2T_Loft_Ladder_Instruction_Manual_A5_Rev1219_PRINT

   11

11/12/2019   16:13

Summary of Contents for 3663602522508 / 3663602548140 LL2T

Page 1: ...3663602522508 3663602548140 LL2T PN115998 01 Macallister_LL2T_Loft_Ladder_Instruction_Manual_A5_Rev0618_V2 indd 1 22 06 2018 14 03 PN115998 01 Macallister_LL2T_Loft_Ladder_Instruction_Manual_A5_Rev1219_PRINT 1 11 12 2019 16 13 ...

Page 2: ...A1 2010 B Ces produits sont conformes à la certification de l Union Européenne d après EN14975 2006 A1 2010 28kg 3663602522508 28 7kg 3663602548140 A Weight of the ladder B Poids de l échelle PN115998 01 Macallister_LL2T_Loft_Ladder_Instruction_Manual_A5_Rev0618_V2 indd 1 22 06 2018 14 03 PN1 PN115998 01 Macallister_LL2T_Loft_Ladder_Instruction_Manual_A5_Rev1219_PRINT 2 11 12 2019 16 13 ...

Page 3: ...45 Ø3 5 x 16 M6 x 20 12 13 14 15 16 20 21 22 30 23 PN115998 01 Macallister_LL2T_Loft_Ladder_Instruction_Manual_A5_Rev0618_V2 indd 2 22 06 2018 14 03 PN115998 01 Macallister_LL2T_Loft_Ladder_Instruction_Manual_A5_Rev1219_PRINT 3 11 12 2019 16 13 ...

Page 4: ... mm Pos 3 A 90mm 2 H A A Max cm EAN Pos 1 Pos 2 Pos 3 3663602522508 278 282 5 287 3663602548140 278 282 5 287 20 4 02 18 18 2 I 18 1 18 2 18 3 21 A 18 18 I 2 18 1 18 2 18 3 A 2 A Assembly B Assemblage 01 PN115998 01 Macallister_LL2T_Loft_Ladder_Instruction_Manual_A5_Rev0618_V2 indd 3 22 06 2018 14 03 PN1 PN115998 01 Macallister_LL2T_Loft_Ladder_Instruction_Manual_A5_Rev1219_PRINT 4 11 12 2019 16 1...

Page 5: ...mm 14 03 4 03 04 A Assembly B Assemblage 01 PN115998 01 Macallister_LL2T_Loft_Ladder_Instruction_Manual_A5_Rev0618_V2 indd 4 22 06 2018 14 03 PN115998 01 Macallister_LL2T_Loft_Ladder_Instruction_Manual_A5_Rev1219_PRINT 5 11 12 2019 16 13 ...

Page 6: ... 1 R1 99380 AYP021015 Attention 1 R1 99380 AYP021015 Attention 07 A Assembly B Assemblage 01 PN115998 01 Macallister_LL2T_Loft_Ladder_Instruction_Manual_A5_Rev0618_V2 indd 5 22 06 2018 14 03 PN1 PN115998 01 Macallister_LL2T_Loft_Ladder_Instruction_Manual_A5_Rev1219_PRINT 6 11 12 2019 16 13 ...

Page 7: ... installation allez à la page 11 1 2 3 1 2 3 08 B A B A B B 11 A Assembly B Assemblage 01 PN115998 01 Macallister_LL2T_Loft_Ladder_Instruction_Manual_A5_Rev0618_V2 indd 6 22 06 2018 14 03 PN115998 01 Macallister_LL2T_Loft_Ladder_Instruction_Manual_A5_Rev1219_PRINT 7 11 12 2019 16 13 ...

Page 8: ...sembled and fitted correctly these instructions should be followed carefully If you have any difficulties contact an expert for installation advice WARNING DO NOT DISMANTLE the loft ladder once it has been assembled NB For models in which the ladder is fixed to the trapdoor If during installation you wish to detach the ladder to reduce the weight of the loft ladder loosen the screws between the me...

Page 9: ...ant that cladding is fitted firmly and correctly When affixing cladding the ladder must NOT be loaded 05 Attaching the loft ladder One fitter goes up into the loft room taking all the tools he needs The other fitter remains below Lift the ladder up into the loft Before lowering the loft ladder into the opening from above attach 2 supporting planks under the ceiling opening The loft ladder rests on...

Page 10: ...wer section from your dealer Do NOT allow the ladder to rest on a box blocks platform or similar Such constructions are unsafe and unstable and do not provide appropriate permanent support for the ladder 07 How to use the ladder The following drawings show how to use the loft ladder safely see figure 9 NOTE If your building construction differs from installation guide above consult an expert WARNI...

Page 11: ...ches or locks are fully engaged before ascending the ladder Ensure both ladder feet rest firmly on the floor before climbing the ladder Inspect the ladder before climbing see above do not use if damaged Only wear suitable footwear whenever ascending or descending the ladder Maintain 3 points of contact by gripping the handrail or ladder stiles when ascending or descending Do not overload the ladde...

Page 12: ... doit être assez fort pour soulever l escalier escamotable au plafond car l escalier escamotable pèse jusqu à 28 kg EAN 3663602522508 28 7 kg EAN 3663602548140 selon le modèle 02 Instructions d installation Pour s assurer que le produit est assemblé et monté correctement ces instructions doivent être suivies attentivement Si vous rencontrez des difficultés contactez un expert pour obtenir des cons...

Page 13: ...lace dans la trémie lors de l installation il est conseillé d installer des supports provisoires Si un revêtement doit recouvrir la trappe il faut installer l escalier escamotable dans la trémie à une hauteur plus élevée correspondant à l épaisseur du revêtement Le matériau de revêtement ne doit pas peser plus de 6 kg par m2 L épaisseur du matériau de revêtement ne doit pas dépasser 12 mm Nous rec...

Page 14: ... sur le sol voir schéma 8 N utilisez PAS l escalier si toutes les sections de l escalier ne sont pas alignées Si l escalier est trop long raccourcissez une nouvelle fois les limons Si l escalier est trop court commandez une nouvelle section inférieure auprès de votre fournisseur Ne laissez PAS l escalier reposer sur une boîte des cales une plate forme ou un autre élément similaire Ces types de con...

Page 15: ...gés avant de monter l escalier Assurez vous que les deux pieds de l escalier reposent bien sur le sol avant de monter l escalier Inspectez l escalier avant de monter voir ci dessus ne l empruntez pas s il est endommagé Portez uniquement des chaussures appropriées en montant ou en descendant l escalier Gardez 3 points de contact en saisissant la main courante ou les montants de l escalier en montan...

Page 16: ...cante UK Manufacturer Kingfisher International Products Limited 3 Sheldon Square London W2 6PX United Kingdom EU Manufacturer Kingfisher International Products B V Rapenburgerstraat 175E 1011 VM Amsterdam The Netherlands www kingfisher com products Distributor B Q Limited Chandlers Ford Hants SO53 3LE United Kingdom www diy com Screwfix Direct Limited Trade House Mead Avenue Yeovil BA22 8RT United...

Reviews: