Ingeniería de Servicio
- 65 -
Fault Codes
Fault
Code
(Hex)
Name
Description
Repair Action
7
Flood
Warnin
g Level
by
Pressu
re.
Pressu
re level
exceed
s 16.5
inches
above
pressu
re port.
Main micro received
and extended period
of pressure readings
that is greater than
maximum allowable
fill volume. Pressure
16.5”. Voltage output
must be present.
Could mean water did
get that high due to
briefly stuck water
valve. Voltage output
of sensor too high for
actual water level
because of sensor or
water in pressure
tube increasing
pressure.
This can happen if a large wet load is placed
in the washer.
Check pressure tube for pinches where it
goes through top cover grommet.
Check pressure tube for trapped water.
Check for any leaking water valves.
Check the output voltage from the pressure
sensor to ensure it matches the water level in
the basket according to the pressure sensor
chart. If it does not, the control will need to be
replaced as the pressure sensor is mounted
directly to the control.
Summary of Contents for GTW220BMKWW
Page 9: ...Ingeniería de Servicio 9 Model Graphics ...
Page 36: ...Ingeniería de Servicio 36 Lift the basket out of the tub Remove the tub washer ...
Page 38: ...Ingeniería de Servicio 38 Disengage the rod and spring suspension from the tub assembly ...
Page 41: ...Ingeniería de Servicio 41 Bottom Component View ...
Page 51: ...Ingeniería de Servicio 51 Schematic ...
Page 52: ...Ingeniería de Servicio 52 Control Board User Interface ...
Page 74: ...Ingeniería de Servicio 74 Cycle Overview ...
Page 75: ...Ingeniería de Servicio 75 Cycle Overview ...
Page 76: ...Ingeniería de Servicio 76 Cycle Overview ...
Page 77: ...Ingeniería de Servicio 77 Cycle Overview ...
Page 78: ...Ingeniería de Servicio 78 Cycle Overview ...
Page 79: ...Ingeniería de Servicio 79 Cycle Overview ...
Page 80: ...Ingeniería de Servicio 80 Cycle Overview ...
Page 81: ...Ingeniería de Servicio 81 Cycle Overview ...
Page 82: ...Ingeniería de Servicio 82 Cycle Overview ...
Page 83: ...Ingeniería de Servicio 83 Cycle Overview ...
Page 84: ...Ingeniería de Servicio 84 Cycle Overview ...
Page 85: ...Ingeniería de Servicio 85 Cycle Overview ...
Page 86: ...Ingeniería de Servicio 86 Cycle Overview ...