Due to individual site variations, exact 

guidelines for every situation cannot be 

supplied. The recommended framing and 

dimensional requirements shown are 

for a typical application and may vary, 

depending on site requirements.

The dimensions shown in Figure 1a and 

1b are from the surfaces where the unit 

will be attached. This surface can be 

bare studding, dry wall or other suitable 

underlayment material.

IT IS IMPORTANT THAT THE FLOOR 

AND ALL FRAMING BE SQUARE 

AND LEVEL

. Framing should be done 

using accepted materials and construction 

techniques, in accordance with all 

applicable codes.

Installation Procedure

With the unit positioned in the alcove, 

several details must be checked prior to 

securing the unit in place (Figure 2a, 2b 

and Figure 2c);

ü

  Confirm dam is resting flush on the floor.

ü

 Confirm drain alignment.

ü

  Confirm the top of unit is level on all sides.

ü

 Confirm the unit is square in the alcove 

framework.

ü

 Confirm the front inside corner is plumb 

at each end. (This is critical for the 

proper installation of an enclosure)

The unit must be positioned square in 

the alcove framework.

 The use of shim 

or filler material behind the fastening flange 

at each framing member may be required 

to maintain the unit in the proper position.
After the unit is confirmed leveled and square 

in the alcove, drill a 1/8 inch hole through the 

fastening flange at each framing member. 

THE BOTTOM OF ALL HOLES IN THE 

FLANGE HAVE TO BE AT LEAST 8MM (0.3 

INCHES) ABOVE THE BASE THRESHOLD!

  

Secure the unit in place across the back 

wall first, followed by the flanges at each 

end, using 1-1/4 inch long screws or other 

appropriate fasteners. Continuously check 

to confirm the base remains square within 

the alcove as it is being secured. (Figure 

3a and 3b)

NOTE: IF UNIT IS EQUIPPED WITH 

LEVELING LEGS PUT SHIMS UNDER 

THEM IN ORDER TO LEVEL THE 

BASE 

Figure 2a - 

Unit

Installation

Procedure

Wall

Framing

Fastening

Flange

1. Position the 

Shower Pan

in Framed Area

Confirm bottom of front dam is 

resting flush on the floor along 

the entire length of pan.

Wall

Framing

Figure 2b - 

Unit

Installation

Procedure

Wall

Framing

Fastening

Flange

2. Level the

Shower Pan

in Framed Area

Confirm the shower pan is level 

from side-to-side across the 

front and the back of the unit.

NOTE: If unit is equipped with

leveling legs put shims under

them in order to level the base

Figure 2c - 

Unit

Installation

Procedure

Wall

Framing

Fastening

Flange

3. Square the

Shower Pan

in Framed Area

Confirm the shower pan is 

square within the framed area 

at all corners.

3

Summary of Contents for SPL 3838

Page 1: ...e for reference only Any critical dimensions required for installation should be taken directly from the unit being installed Any independent changes made to the unit or to any options and accessories...

Page 2: ...ough In Depth Drain Center Drain Center Alcove Lenght Unit Length Drain Cut Out 5 A B D C E Drain Cut Out Fixture Blocks MODEL A B C D E 106785 SPL 3838 38 1 8 37 1 4 37 18 19 106788 SPL 3850 50 1 8 3...

Page 3: ...ach framing member may be required to maintain the unit in the proper position After the unit is confirmed leveled and square in the alcove drill a 1 8 inch hole through the fastening flange at each f...

Page 4: ...urs Rinse surface thoroughly For extreme cases buff area with white automotive polishing compound until stain disappears and apply a quality automotive wax to surface Wall Framing Fastening Flange Fig...

Page 5: ...tion Toutes les dimensions des unit s publi es sont titre de r f rence seulement Toutes les dimensions critiques requises pour l installation doivent tre prises directement partir de l unit en cours d...

Page 6: ...finition Centre de drainage Longueur Alc ve Longueur Unit D coupe pour drain 5 A B D C E D coupe pour drain Blocs de montage MOD LE A B C D E 106785 SPL 3838 38 1 8 37 1 4 37 18 19 106788 SPL 3850 50...

Page 7: ...age derri re la bride de fixation au niveau de chaque l ment d encadrement peut tre n cessaire pour maintenir l unit dans la position appropri e Apr s avoir confirm que l unit est nivel et equerre per...

Page 8: ...t la surface Montant en bois Bride Figure 3a S curiser l unit Percer un trou de 1 8 pouce travers la bride chaque membre d encadrement 0 3 8 mm Remplir les trous avec du silicone Note Chaque trou dans...

Page 9: ...al finalizar la instalaci n Todas las dimensiones de unidades publicadas son solo para referencia Cualquier dimensi n cr tica requerida para la instalaci n debe tomarse directamente de la unidad que...

Page 10: ...de la unidad Centro de desag e Centro del desag e Largo del nicho Largo de la unidad Recorte del desag e 5 A B D C E Corte desag e Bloques de fijaci n MODELO A B C D E 106785 SPL 3838 38 1 8 37 1 4 3...

Page 11: ...en cada miembro de la estructura para mantener la unidad en la posici n adecuada Despu s de confirmar que la unidad est nivelada y a escuadra en el nicho taladre un orificio de 1 8 de pulgada a trav s...

Page 12: ...cie Estructura muro Brida de fijaci n Figura 3a Asegurando la unidad Taladre un agujero de 1 8 a trav s de la brida en cada miembro de la estructura 0 3 8 mm Llenar los agujeros con silicona Nota la p...

Page 13: ...transf rable un propri taire subs quent Ni le distributeur ni le concessionnaire autoris MAAX ni personne d autre n est autoris faire d affirmations de repr sentations ou de garanties autres que celle...

Page 14: ...14...

Page 15: ...tends only to the original owner end user for personal household use For commercial uses additional limitations apply For accessing product Limited warranty please visit www maax com ca warranty LIMIT...

Page 16: ...ce technique Servicio T cnico Printed in Canada Imprim au Canada Impreso en Canad MAAX Bath Inc 2008 TO BE REMOVED FOR USE BY THE OCCUPANT RETIRER DE L UNIT AVANT L UTILISATION RETIRE DE LA UNIDAD ANT...

Reviews: