Whirlpool System Care and Cleaning

WARNING!

NEVER USE ABRASIVE MATERIALS, 

NOR ABRASIVE CLEANERS ON 

THE WHIRLPOOL TRIM.  (JETS, AIR 

CONTROLS AND SUCTION COVERS)

Only use MILD liquid detergent on trim! 

Incorrect cleaning materials can 

damage finish on trim, drain/overflow 

and supply valves.

READ AND FOLLOW ALL PACk AGE 

LABELS AND INSTRUCTIONS!

Step 1:

Step 2:

Step 3:

Whirlpool System Trouble Shooting

Whirlpool did not start?

 

 

 

Pump «Hums», but no water action?

 

 

 

HAND TIGHTEN UNIONS 

ONLY!

)  

Restricted flow from foot or side jet(s)?

 

 

 

Water has excessive foaming?

 

WARNING!

any  Servi Cin G not mentioned 

aBove  Should  Be per Formed 

By a quali Fied  Servi Ce 

repre Sentative.

Whirlpool System Operation

WARNING!

AVOID OPERATING THE WHIRLPOOL 

SYSTEM WITHOUT ADEQUATE WATER 

IN THE TUB

Step 1:

Step 2:

Step 3:

 

 

Figure 4 - Minimum Water Level

Water level must be to top of 

trim ring on highest jet 

before starting the whirlpool  

Jet 

Nozzle

Jet Trim

Ring

Bodywrap Whirlpool System 
Assembly And Operation Guide

-4-

10023064

Through routine use, the whirlpool system
can collect residues from soap, bath
additives and natural body oils. Additional
deposits can also collect from minerals or
particles found in the water.

EXTREME CAUTION is urged regarding
the use of any cleaner, acid or solvent on
the whirlpool system trim.

>  Check GFCI circuit breaker.
>  Push on/off button to ensure system is
    turned < ON >.

>  Have wiring connections checked.
    (Call installer or electrician).
>  Thermal limiter (in pump) may have
    engaged. (Call installer or supplier).

>  Check air controls, confirm open.

>  Check air controls, confirm open.

>  Make sure water is to the top of the trim
    ring on the highest jet.

>  Check suction line connection at pump
    intake port.

>  Check highest side jet for blockage.
    (Rotate internal jet cartridge counter-
    clockwise for removal.

>  Have pump checked for impeller
    obstruction or other malfunction. (Call
    installer or supplier).

>  Confirm side or foot jets are open to full
    flow. (Adjust center internal jet cartridge
    counterclockwise for removal).

>  Have pump-to-jet supply line checked
    for blockage. (Call installer or supplier).

>  Clean and service whirlpool system.
    (See

 Whirlpool System Care and

    

 Cleaning

 section.

>  Confirm pump-motor is plugged in.
>  Confirm air hose from on/off switch to
    the pump motor is securely in place 
    and is not crimped.

Close the drain and fill tub to
desired water level. Water level
must be at least to the top of trim
ring on highest jet before whirlpool
system is started.  (See Figure 4).

Before using the whirlpool for the first 
time, the system should be cleaned as
described in the 

Whirlpool System Care

and Cleaning

 section of this guide.

The following procedure is recommended
to remove most deposits and avoid
major accumulations inside the system
piping. The actual schedule for cleaning
will depend on system usage and water
quality, but should not exceed 90 days.

Fill tub to the top of the trim ring
on the highest jet with lukewarm
water.  (Figure 4)

Add 1 cup low-sud-sing automatic
dishwater detergent and run the
whirlpool system for 20 minutes
(1 complete timer cycle)

Drain tub, refill with clean water and
operate the system for 20 minutes
(1 complete timer cycle) to rinse.
(Rinse thoroughly)

Occasionally sanitze the system by following
the cleaning procedure above, but subsitute
1 cup of household bleach for the 
dishwasher detergent.
(Rinse very thououghly)

Refer to the unit installation for guidelines
on the unit surface care and cleaning.

Check both air controls as shown
in Figure 5. Avoid starting the
whirlpool with the air controls in
the fully closed position.
If the air controls are tightly closed,
rotate the knob counterclockwise
one-half revolution before starting
the system.
To start the whirlpool, gently touch
the button as shown in Figure 6.
The built-in 20-minute timer cycle
automatically begins when the
system is started.
To stop the whirlpool during the
timer cycle or to restart the system,
gently touch the switch button.
On systems equipped with an in-line 
heater, the heater is automatically
operated though the internal heater
controls.

Summary of Contents for AKER

Page 1: ...dures and any referenced publications before starting is important in avoiding unnecessary problems resulting in an improper assembly or operation It is the sole responsibility of the installer to determine prior to installation the requirements necessary for compliance with all codes involving the unit and the installation All paperwork packaged with the unit and any associated options or accesso...

Page 2: ...own in Figure 2 If the unit has a factory fitted Alternate pump location refer to the Supplemental Assembly information packaged with the accessory items for additional item checks before continuing Notify your supplier immediately if any questions or problems are encountered during this process Basic Whirlpool System Check Check to be certain the air hose is secured to the on off button and to th...

Page 3: ...pleting all water supply drain and electrical connections use the following procedure to test the system and all fittings for leaks Close the drain and fill to the top of trim ring on the highest jet Start the whirlpool and operate continuously for 20 minutes 1 complete timer cycle During the cycle adjust the air controls Figure 5 and the control Figure 10 through the complete range and check each...

Page 4: ...ow Adjust center internal jet cartridge counterclockwise for removal Have pump to jet supply line checked for blockage Call installer or supplier Clean and service whirlpool system See Whirlpool System Care and Cleaning section Confirm pump motor is plugged in Confirm air hose from on off switch to the pump motor is securely in place and is not crimped Close the drain and fill tub to desired water...

Page 5: ...tion as shown in Figure 7 To change the whirlpool action during the system operating cycle adjust air control knobs Opening turning counterclockwise the air control allows more air to be mixed with the water coming out of the jet nozzle for increased whirlpool action Closing turning counter clockwise the air control reduces air at the jet for less whirlpool action See Figure 5 The micro pulse back...

Page 6: ...ESTING NAHB Certain models are pending approval Certification may be ended by MAAX or certification agencies without notice MAAX AKER BODYWRAP SYSTEM are regestered trademarks of MAAX Bath INC SELECTAFLOW s a trademark of MAAX Bath Inc This warranty shall not apply following incorrect operating procedures breakage or damages caused by fault carelessness abuse misuse misapplication improper mainten...

Reviews: