MA lighting MA 2Port Node Quick Manual Download Page 45

 

44 

Gerätetyp / model:

 

MA 2Port Node 

 

 

 

 

MA 2Port Node onPC 1k 

MA 2Port Node onPC 2k

 

 

Optionen / options:…………………………………………….

 

 

Seriennummer / serial number:…………………………….

 

 
Baujahr / year of manufacture:

……………………………

 

 
Distributor:

 

 

Summary of Contents for MA 2Port Node

Page 1: ...MA 2Port Node QuickMAnual Version XIX 6 deutsch english Art Nr 1366M 00163...

Page 2: ......

Page 3: ...ht ein 2 TFT Display und vier Status LEDs Zus tzlich befindet sich ein USB Port f r einen optionalen Firmware Update per USB Stick Auf der Ger ter ckseite sind der Hauptschalter ein powerCON und ether...

Page 4: ...re betrieben werden Hersteller MA Lighting Technology GmbH Dachdeckerstra e 16 D 97297 Waldb ttelbrunn Mehr Informationen und detaillierte Manuals f r die onPC Software unter www malighting com Oft ge...

Page 5: ...3 x 1 8 x 7 3 inch 2 DMX OUT XLR 5 pin an der R ckseite Die DMX OUTs k nnen auch zu DMX IN konfiguriert werden Ethernet RJ 45 Netzwerk Anschluss USB Anschluss an der Front nur f r Updates per USB Stic...

Page 6: ...ierte und gesch tzte Kabel verwenden min 3 x 1 0mm Kabel und Stecker sind nicht im Lieferumfang enthalten Erforderlicher Steckertyp Power In PowerCon blau von Fa NEUTRIK AG Liechtenstein Erforderliche...

Page 7: ...usschlie lich der Anwender verantwortlich bei Nichtbeachten k nnen Personen oder Sachsch den entstehen Verwenden Sie f r Lagerung und Transport eine sichernde und sch tzende Transportvorrichtung Stell...

Page 8: ...Quickstart ON OFF Wartung Konformit t 07 Symbole und Warnzeichen I 0 Achtung Warnung vor einer Gefahrenstelle Achtung Warnung vor Gef hrlicher elektrischer Spannung Hauptschalter AN AUS Wechsel strom...

Page 9: ...uss Stellen Sie keine Gegenst nde auf das Netzkabel und achten Sie darauf dass niemand auf das Kabel treten kann Wird ein Verl ngerungskabel benutzt muss sichergestellt werden dass die Summe der Nennl...

Page 10: ...Wartung Konformit t 09 Warnhinweise Die Wartung des Ger tes darf ausschlie lich durch geschultes Personal durchgef hrt werden da beim ffnen und oder Entfernen von Abdeckungen spannungsf hrender Teile...

Page 11: ...F bis 122 F Luftfeuchte Betrieb 20 bis 90 relative Luftfeuchtigkeit keine Betauung Lagerung Transport 10 bis 90 relative Luftfeuchtigkeit keine Betauung Umgebung Bitte alle Sicherheitshinweise beachte...

Page 12: ...nada Das Netzteil passt sich automatisch an die Netzspannung an Hauptschalter Zum Ein Ausschalten des Ger tes USB Anschluss zum Updaten per USB stick keine Peripherieger te anschlie en MENU Taster zum...

Page 13: ...nPC command wing und MA onPC fader wing addieren in beliebiger Kombination Parameter bis zur maximalen Parameterzahl Rechenbeispiel 1 grandMA2 onPC MA onPC command wing 2 048 Parameter MA 2Port Node o...

Page 14: ...2Port DMX Output z B 30 Frequenz des DMX Ausgangs in Hz max 30Hz sind m glich IP Adresse z B 192 168 0 244 Mode MANET2 oder ARTNET Nummer der Session z B Session 1 der MA 2PORT Node befindet sich in d...

Page 15: ...ige wieder auf das erste Men zur ck Select Mode Mit dem MENU Button NONE MANET 2 oder ARTNET einstellen Info Mode hier k nnen keine Einstellungen vorgenommen werden Identify Mode Markiert in der Konso...

Page 16: ...ch erscheint die Anweisung Please press key for update recovery Jetzt die Men Taste dr cken Jetzt erscheint die Anweisung Please press key for FORMAT Gleichzeitig startet f r ein paar Sekunden ein Lau...

Page 17: ...n MA 2Port Node in der bersicht selektieren Den Button SOFTWARE UPDATE dr cken Nach dem automatischen Reboot des MA 2Port Node muss das Feld Version grau unterlegt sein HINWEIS wenn im Display der Hin...

Page 18: ...In der Konsole oder onPC das Men SETUP NET WORK MASTER MA NETWORK CONFIGURATION DMX NODE ffnen Bei Bedarf die Firmware Version des MA 2Port Node angleichen falls das Feld Version rot unterlegt ist IP...

Page 19: ...espeichert sie muss mit SAVE TO DEFAULT gesondert gespeichert werden Laden der Konfiguration Im Men SETUP NETWORK MA NETWORK CONFIGURATION DMX NODES den Button LOAD FROM DEFAULT dr cken Falls nach dem...

Page 20: ...scharfe Reiniger verwenden Darauf achten dass die ffnungen f r die K hlluft frei sind Je nach Umgebungsbedingung ist es ratsam das Ger t alle 2 5 Jahre durch einen autorisierten Service reinigen zu l...

Page 21: ...oduktkategorie Kontrollger t Produktnamen MA 2Port Node MA 2Port Node onPC 1k MA 2Port Node onPC 2k den folgenden Richtlinien sowie den harmonisierten Normen entsprechen Sicherheit EN60065 EN60950 1 L...

Page 22: ...ren am Laptop oder PC Mit der grandMA 3D Software kann es zum perfekten Designstudio erg nzt werden und es ist die Grundlage f r die Funktion des MA 2Port Node onPC Die grandMA2 onPC und grandMA 3D So...

Page 23: ...en in der Licht Szene ger stet Au erdem bietet das neu entwickelte faderwing bis zu 60 zus tzliche Executor Fader Und die grandMA2 full size kann die showfiles der Serie 1 in einem speziellen Serie1 M...

Page 24: ...ere is a USB port for optionally update of firmware via USB stick The mains switch is located on the back along with the powerCON and etherCON connectors as well as two DMX ports The MA 2Port Node is...

Page 25: ...mbH Dachdeckerstra e 16 Germany D 97297 Waldb ttelbrunn For more information and detailed manuals see www malighting com Please check our Frequently Asked Questions first that you can find online at w...

Page 26: ...85mm 8 3 x 1 8 x 7 3 inch 2 DMX OUT XLR 5 pin on the rear side Each DMX OUT can be individually configured as DMX IN Ethernet RJ 45 network connector USB Port connector on the front side For update vi...

Page 27: ...ng necessary Power cable Only adequately protected cables may be used min 3 x 1 0mm Power supply cabel and connector not included ex works Socket type Power In PowerCon blue by NEUTRIK AG Liechtenstei...

Page 28: ...and for observing the safety regulations of the manufacturer when using means of transport Non compliance can result in personal injury or material damage Use protective transport device for transport...

Page 29: ...ment Quickstart Connect Quickstart ON OFF Maintenance Conformity 28 Symbols and warning labels I 0 Warning Danger Area Warning Danger of electric shock Supply voltage ON OFF Alternating current AC Dis...

Page 30: ...s provided with a safety plug This plug can only be used with safety sockets These precautions should by all means be followed If the plug should not fit into a given socket e g the case with old sock...

Page 31: ...kstart Connect Quickstart ON OFF Maintenance Conformity 30 Electric shock warning The unit should be serviced by qualified personnel only as live parts may be exposed when opening and or removing cove...

Page 32: ...nsport 10 C up to 50 C 14 F up to 122 F Humidity Operation 20 up to 90 relative humidity no condensation Storage Transport 10 up to 90 relative humidity no condensation Environment Follow all the IMPO...

Page 33: ...matic operation no switching necessary The open end must be fitted with a shock proof plug and must meet the local requirements Main switch To turn on or off the device USB socket To update via USB st...

Page 34: ...le The maximum parameter count with grandMA2 onPC is 4 096 parameters Second rule In any combination MA 8Port Nodes onPC MA 4Port Node onPC MA 2Port Node onPC as well as MA onPC command wing and MA on...

Page 35: ...l show this menu Name of MA 2Port Node e g 2Port DMX Output e g 30 frequency of DMX output in Hz max 30Hz possible IP Address e g 192 168 0 244 Mode MANET2 or ARTNET Number of Session e g Session 1 MA...

Page 36: ...After a short time display returns to the above menu Select Mode Use the MENU button to select NONE MANET 2 or ARTNET Info Mode no settings possible Identify Mode identifies this MA 2Port Node by flas...

Page 37: ...e following instruction appears Please press key for update recovery press button MENU now Now following instruction appears Please press key for FORMAT Simultaneously for an few seconds a loading bar...

Page 38: ...32 with installation program 4port_v1 x y update Open menu SETUP NETWORK MA NETWORK CONFIGURATION DMX Nodes at the console or onPC Connect USB stick with the console Select the appropriate MA 2Port No...

Page 39: ...l only show the most important settings For configuring a node you have to use a grandMA console or the onPC software Console or onPC open menu SETUP NET WORK MASTER MA NETWORK CONFIGURATION DMX NODE...

Page 40: ...d SAVE SHOW settings of the MA 2Port Node are not stored settings must be stored with SAVE TO DEFAULT Load Configuration settings Open menu SETUP NETWORK MA NETWORK CONFIGURATION DMX NODES and press b...

Page 41: ...surface only with dry soft cloth Do not use any liquid cleaner or compressed air Do not use any solvent Check ventilation holes are clear Depending on the environment we recommend to clean the device...

Page 42: ...ategory Control unit Name of products MA 2Port Node MA 2Port Node onPC 1k MA 2Port Node onPC 2k complies with the following product specifications and harmonized standards Safety EN60065 EN60950 1 LVD...

Page 43: ...used for running programming or offline programming a show Furthermore it is expandable to a complete design studio by connecting it to grandMA 3D and it s the basis for the function of the MA 2Port...

Page 44: ...ghting segments Intuitive and fast control over all connected fixtures and channels in different styles is self evident Furthermore the newly developed faderwing provides in addition up to 60 executor...

Page 45: ...44 Ger tetyp model MA 2Port Node MA 2Port Node onPC 1k MA 2Port Node onPC 2k Optionen options Seriennummer serial number Baujahr year of manufacture Distributor...

Page 46: ...45 Notizen notes...

Page 47: ...ormation contained in this booklet were correct at time of printing By continuing our company s efforts to optimize our products continuously it may happen that information is outdated at the time you...

Reviews: