Wireless keyfobs 

 

Supported functions  

The wireless keyfob has 4 buttons - Full Arm, Home Arm, Disarm and Panic. By default, only the Full Arm 
and Disarm buttons are active.  

To enable the STAY Arm button, you need to have at least one STAY zone. Please refer to the 
“Con guring the zones” section.  

To enable the Panic button of the keyfob, please refer to the “Con

ring the panic button” section.   

Pairing a wireless keyfob  

The RControl Alarm panel supports up to 16 wireless keyfobs. Two keyfobs are included in the standard 
kit and they are already paired.  

To use additional keyfobs you should  rst pair them with the alarm panel.  

NOTE: 

To be able to enter learning mode, make sure that the panel is

 DISARMED! 

To enter learning mode, press the “PAIR” button of the RF receiver of the panel. The red LED indicator of 
the RF receiver will turn ON. Press any button of the wireless keyfob 

(hold the button at least 1 sec)

The siren will beep once, which indicates that the keyfob was paired and the procedure was successfully 
completed.  

NOTE: 

It’s recommended to pair the keyfob with Disarm button. In this way, you will not arm the panel by 

mistake, which will not allow you to pair the next keyfobs before you disarm the panel.   

The learning mode lasts 30 seconds. If the receiver does not receive signal from the keyfob in the 
timeframe of 30 seconds, the pairing procedure will be terminated. The siren will beep 4 times to indicate 
an error.  

When a new keyfob is paired, the panel reports an event “Access Granted, User N” with ContactID E-422. 
Each keyfob reports with di erent user number (starting from 101). 

You need to repeat the pairing procedure for each additional keyfob.  

NOTE: 

To allow the panic button on the keyfob please refer to section 

“Con guring the panic button”.

 

Assigning a keyfob 

erent partition 

 

By default, the keyfob controls the  st partition after the pairing procedure. If there is a more than one 
partition set, you can set the keyfob to control a partition. To do that, log in the RControl Admin Portal, 
navigate to RControl Alarm menu, section Keyfobs and choose the desired Partition for each keyfob.  

NOTE: 

By default, each keyfob controls only one partition. If you want to control both partitions with a 

single keyfob, choose Partition=All for that keyfob in the RControl Admin portal. The buttons of the keyfob 
from the upper row will control Partition 1, the buttons from the lower row will control Partition 2. You will 
not be able to use Home Arm and Panic features of that keyfob.  

Summary of Contents for RControl-LA

Page 1: ...M2M Services Ltd 1 Kukush Str building M8 Sofia 1309 Bulgaria www m2mservices com RControl LA Smart Hybrid Alarm System Installation and Programming Guide Doc No 04003 V1 0 10 2018...

Page 2: ...keyfobs 11 Labelling the keyfobs 11 Con guring the panic button of the keyfob 11 Wireless detectors 12 Pairing a wireless detector 12 Disabling a wireless detector 13 Deleting a wireless detector 13...

Page 3: ...o its intended purpose and does not cover damage to the Device caused by installation or removal of the Device or any of its components This warranty is voided if the Device has been damaged by improp...

Page 4: ...ust be done only by qualified safety aware personnel Don t disassemble or refit the Device Do not attempt to personally repair it Main powers must be disconnected before any installation or tuning wor...

Page 5: ...artition control panel with the following features Built in GPRS communicator Remote control via Smartphone 2 Partitions 8 Wired zones 16 with zone doubling 32 Wireless zones Supports up to 16 keyfobs...

Page 6: ...output 200 mA Power Requirements Battery 12 V 2 6 Ah minimum rechargeable sealed lead battery Digital Communicator Specification Built in digital communicator Frequency Dual band UMTS HSPA 850 1900 MH...

Page 7: ...choose location that is below ground level as this can impair wireless reception Do not choose location that can be easily viewed from outside the premises The Control Panel should be mounted on the w...

Page 8: ...te FCC regulations Keypad Mount the keypad where it is accessible in a dry and secure location Perform the following steps to mount the keypad Remove the keypad front plate by inserting a screwdriver...

Page 9: ...the alarm panel Battery Plug the battery connector into the connector on the control panel s circuit board Plug the red cable to the of the battery and the blue one to the of the battery Ensure the ba...

Page 10: ...take which will not allow you to pair the next keyfobs before you disarm the panel The learning mode lasts 30 seconds If the receiver does not receive signal from the keyfob in the timeframe of 30 sec...

Page 11: ...e for each keyfob Labelling the keyfobs Each keyfob reports with different user number in the range between 101 116 When pairing the keyfobs they automatically receive labels Keyfob 101 Keyfob 116 The...

Page 12: ...beep once and the red PAIR LED will turn off The siren will beep four times if there was an error during the pairing When a new detector is successfully paired the panel reports an event Module Added...

Page 13: ...all keyfobs and wireless detectors NOTE This procedure will delete all paired keyfobs and wireless detectors To pair the keyfobs and the wireless detectors again you should repeat the pairing procedu...

Page 14: ...tor as many times as required until the panel recognizes the sensor When the sensor is successfully enrolled the panel will beep once and the red PAIR LED will turn off The siren will beep four times...

Page 15: ...wer you can configure the delay in seconds after which the device will report the mains power outage Configuring the Battery level thresholds In section Battery field Battery low you can set a low vol...

Page 16: ...en the alarm cycle time expires the zone restore event will be reported only when the zone is really restored In addition even when there was a restore during the alarm cycle this restore will not be...

Page 17: ...h prevent the panel from arming Follow STAY zone This is a Follow zone that is not monitored when the panel is partially armed STAY Arm Instant STAY zone This is an Instant zone that is not monitored...

Page 18: ...pressed 24 Hours Flood When this zone is violated the panel will immediately latch the alarm output and communicate to the central station The alarm will sound until the alarm cycle duration expires o...

Page 19: ...is strongly recommended that the end user changes the User name and Password and provides an email for password recovery Remote Arming Disarming via the RControl Application To enable the remote contr...

Page 20: ...exit the System Test mode and indicate this with a sound The programming icon will also be off If some of the sensors is not activated the system will not generate a sound indication for exiting a te...

Page 21: ...8 1 0 2 s e c i v r e S M 2 M 1 2 Zone problems Wiring Configuration Faulty detectors Siren not working Check wiring Programming AUX overcurrent...

Reviews: