Allowed values range from 0 to 999999999 (only numbers).
To change the passwords, set the new values with LoRaWEB:
Once the passwords are setted, to gain access from LoRaWEB to the sensor, set the right values before reading from the device:
To bring back the sensor to factory default and reset the passwords, a reset code must be requested to enginko (please provide the DevEUI of the sensor when you
ask for that code).
8 General configuration file
With LoRaWEB is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to
enginko). This is very useful especially in case of multiple devices configuration.
With
“Save”
button an XML file with the actual configuration of the sensor will be generated. This is useful to store or clone the configuration, or to send it to
enginko's support if needed.
8.1 Multi devices configuration
WIth LoRaWEB is possible to configure many devices in an easy way.
For multi-configuration is needed at least one XML file with the parameters to set.
Settings on this file will be applied to all the sensors.
With an additional XLS file is possible to load different LoRa configuration parameters (Activation Type, AppKey, AppEUI, NetKey, DevAddress, Band, Private
option) for each sensor, based on DevEUI.
XLS is prevailing on the XML, so if both files are enabled, if the DevEUI of the device matches one of the DevEUIs in the XLS file, LoRa parameters will be setted