4. How to use 

To use temp. controller

1-1.Connect the sesor on No.17 terminal of the rear side(Use external sesor)

1-2.If sensor is connected on No.17 terminal on the rear side, take it out and use internal sensor.

2.Connect No. 15 of the rear side with an electric outlet and switch on the instrument by No.14 of the rear side..

3.Press No. 8 key of the front side, then the parameter to set temperature will be appeared.

To use Timer

1.Press No.8 key on the front side for 2seconds, then the parameter to set temperature will be appeared.

Minimum 1 minute(0001) to Maximum 99hr59min.(9959)

2.After setting of time, press No. 8 key on the front side, then it return to the initia condition.

3.Press No.10 key on the front side for 2 seconds on timer run, then No. 6 lamp will be switched on and off.

   In case that time is not setted,  it does not run.

4.Press No. 10 key for 2seconds on timer run, then it stop to run..

5.Press No. 9 key for 2 seconds, then the temperature display shows the remaining time.

Press No. 9 key again for 2 seconds, then the temperature display shows setting value.

1.Use without auto-tuning but do it in case of a big temperature difference.

2.Press No.11 key, then it starts with switching on and off.

3.Temperature error could be happened on auto-tuning but it is controlled correctly when auto-tuning is finished..

4.Temperature go higher than the setting value first time but it is returned to normal condition immediately.

   (Over-shoot condition)

5.In case that temperature goes down, it is differ as per the charater of the liquid and the ambient condition.

6.Be careful so that the contents are overflowed from the vessel. It makes the malfunction and damage 

   of the instrument. 

7.In case that the replacement of the sensor or the switch of internal and external sensor are needed,

switch off the power and make it. If it is made under power ON, it cause a wrong operation. 

tlm

Set the time using No. 9 and 10 key.

30

0

6.In case that the set of time is finished, "tENd" is showed and press No.10key to back to the   initial condition.

Su

Press No.9 (downturn) and No.10 (upward) to set the required temperature.

30

4. After setting of the temeprature, press No.8 key on the front side for 2 seconds, then the temperature controller
runs on initial condition.

Su

Prees No. 8 key again.

1

2

8

13

6

9

1

1

5

15

1

16.Sensor S/W

12

14

Front Panel

Rear Panel

Summary of Contents for DMB-1

Page 1: ...avoid electrical shock always 1 Use a properly grounded electrical outlet of correct voltage and current handling capacity 2 Disconnectfrom power supply before servicing To avoid personal injury 1 Do not use in the presence of flammable or combustible materials fire or explosion may result This item contains components which may ignite such materials 2 Keep the item clean Use non abrasive cleaner ...

Page 2: ...parameters in parameter set 2 Displays set value and parameter set SV Displays set value in controlling and parameter value in parameter set Press key No 9 then displays the remaining time 3 Lamp of output control OUT 4 Warning lamp of highest and lowest ALM 5 Auto tuning lamp AT Press key No 11 then it starts PID auto tuning with flikering of the lamp and the lamp turns off when it is finish 6 Ti...

Page 3: ...maticall y set for Auto Tuning 7 I Intergral time Possible to set a 1sec unit within 5 9998 sec range 8 5 ALL Low alarm It sets the lowest alarm limit 0 It is absolute value 4 ALH High alarm It sets the heighest Alarm limit 0 It is absolute value Up key can modulate ON OFF The Timer begins working after current temp reaches set temp After a set time reaches it stops ending Control output The TIMER...

Page 4: ...e 1 Use without auto tuning but do it in case of a big temperature difference 2 Press No 11 key then it starts with switching on and off 3 Temperature error could be happened on auto tuning but it is controlled correctly when auto tuning is finished 4 Temperature go higher than the setting value first time but it is returned to normal condition immediately Over shoot condition 5 In case that tempe...

Page 5: ... a few second and keep the constant speed by arithmetic logic unit Smooth start function 4 In initial operating if the motor does not run give the motor output fast and make it run until speed is arrive at 10rpm so that the motor runs When Err are shown on display Check if the temperature sensor is coneected corretly Check if the wire of the temperature sensor is not down Check if the tempereture ...

Reviews: