CONNECTION DIAGRAM

Connect the unit as in the diagram below.

4

7

6

3

2

5

1

0V

24VDC

FG

SLD

DG

DB

DA

10

+IN0

11

–IN0

1

+CJ0

2

–CJ0

+IN1

–IN1

+CJ1

–CJ1

+IN2

–IN2

+CJ2

–CJ2

+IN3

–IN3

+CJ3

–CJ3

INPUT 0

12

13

3

4

INPUT 1

15

16

6

7

INPUT 2

17

18

8

9

INPUT 3

■ 

Input Connection Example

+INn

–INn

+CJn

–CJn

T/C

+

CJC

SENSOR

+INn

–INn

Short

CJC

SENSOR

+CJn

–CJn

• 

Unused Input Channels

  Close across the unused input terminals as shown below.
   (Choose K (CA) thermocouple for unused channels.)

EXTENSION CONNECTOR

In order to improve EMC performance, bond the FG
terminal to ground.
Caution: FG terminal is NOT a protective conductor terminal.

WIRING INSTRUCTIONS

 

SCREW TERMINAL  

Torque

: 0.5 N·m

 

SOLDERLESS TERMINAL  mm (inch)

Refer to the drawing below for recommended ring tongue 
terminal size.  Spade tongue type is also applicable.  Solder-
less terminal:
Applicable wire size: 0.25 to 1.65 mm2 (AWG 22 to 16)
Recommended manufacturer: Japan Solderless Terminal
MFG. Co., Ltd, Nichifu Co., Ltd

6 (.24) max

3.3 (.13) max

mm (inch)

MASTER CONNECTION

 MASTER CONNECTION

Tx+/Rx+
Tx–/Rx–

SG

Rx+
Rx–

Host PC

DA
DB

DG

SLD

FG

Remote Unit

DA
DB

DG

SLD

FG

Remote Unit

TERMINATOR

TERMINATOR

Be sure to connect the terminating resistor included in the product package to the unit at both ends of transmission line.
The terminator must be connected across DA and DB.
The Host PC can be located other than at the extreme ends of transmission line.

Summary of Contents for R7M-TS4

Page 1: ...be supplied by a Class 2 power supply CONFORMITY WITH EU DIRECTIVES The equipment must be mounted inside the instrument panel of a metal enclosure The actual installation environments such as panel c...

Page 2: ...ary switch 5 4 3 2 1 0 9 8 7 6 Baud Rate Setting 0 38 4 kbps factory setting 1 19 2 kbps 2 9600 bps 3 4800 bps EXTENSION MODULE Combinations with all extension modules are selectable OPERATING MODE Fa...

Page 3: ...ance bond the FG terminal to ground Caution FG terminal is NOT a protective conductor terminal WIRING INSTRUCTIONS SCREW TERMINAL Torque 0 5 N m SOLDERLESS TERMINAL mm inch Refer to the drawing below...

Page 4: ...and cautions when installing R7M are stated below Use control panels with an internal panel plate both made of metal when installing the R7M Make sure to adequately ground the control panel and the in...

Page 5: ...using an electro magnetically shielded control panel By connecting the internal panel plate and the panel cover with an earth strap grounding may be strengthened and EMC may be improved Ground the con...

Page 6: ...dditional measures may be taken depending upon actual installation sites These points of cautions are illustrated in the next page Keep cables as short as possible It prevents noise emissions from the...

Page 7: ...is not effective Points of cautions applicable when wiring the R7M Series To external apparatus Keep the cable as short as possible To external apparatus Shielded Cable Earth Clamp Remove a part of t...

Reviews: