TERMINAL CONNECTIONS

Connect the unit as in the diagram below.

 

EXTERNAL DIMENSIONS  unit: mm [inch]

115 [4.53]

50 [1.97]

5 [.20]

3 [.12]

72 [2.83]

55 [2.17]

(4 [.16])

123 [4.84]

138 [5.43]

DIN rail

(35mm wide)

2‑4.3 dia. 4 deep.

 

CONNECTION DIAGRAM

Note: In order to improve EMC performance, bond the FE terminal to ground.
Caution: FE terminal is NOT a protective conductor terminal.

*

1. The network cable can be connected to either one.

*

1

EtherNet/IP RJ-45 MODULAR JACK

*

1

EtherNet/IP RJ-45 MODULAR JACK

3
4
2

25
26
24

1

14

29
30
28

51
52
50

27

40

4

5

1

24V DC

FE

0V

+24V1

Y7

GND1

+24V2

Y8

GND2

+24V2

Y15

GND2

+24V1
GND1

+24V2
GND2

+24V1

Y0

GND1

OUTPUT Y0

OUTPUT Y7

OUTPUT Y8

OUTPUT Y15

EXC. SUPPLY (IN)

EXC. SUPPLY (IN)

Summary of Contents for R7F4HEIP-DC16B

Page 1: ...easures to ensure the CE conform ity POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 24V DC rating 24V 10...

Page 2: ...ows the signal status ON LED ON OFF LED OFF IP ADDRESS Set the host address 2 digit hexadecimal number in the IP address using rotary switches SA1 and SA2 for the first digit and the second digit resp...

Page 3: ...49 50 51 52 PIN No ID FUNCTION PIN No ID FUNCTION 1 24V1 24V DC 27 24V2 24V DC 2 Y0 Output 0 28 Y8 Output 8 3 24V1 24V DC 29 24V2 24V DC 4 GND1 0V 30 GND2 0V 5 Y2 Output 2 31 Y10 Output 10 6 24V1 24V...

Page 4: ...ve the upper hook of the unit from the DIN rail 1 2 3 SURFACE MOUNTING 1 Insert the two DIN rail mounter sliders until it clicks once as shown below 1 1 2 Mount the unit with M4 screws referring to th...

Page 5: ...43 DIN rail 35mm wide 2 4 3 dia 4 deep CONNECTION DIAGRAM Note In order to improve EMC performance bond the FE terminal to ground Caution FE terminal is NOT a protective conductor terminal 1 The netwo...

Page 6: ...nfigured with the PC configurator software model R7CFG Refer to the users manual of the software for detailed operations CHANNEL BATCH SETTING PARAMETER SETTING RANGE DEFAULT SETTING Output Hold Clear...

Page 7: ...F4HEIP CONNECTION Enter ping command on the Windows MS DOS as follows C WINDOWS ping Enter IP address in decimal ping with 32 bytes of data Reply from bytes 32 time 10ms TTL 64 Reply from bytes 32 tim...

Reviews: