R1MS-GH3
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: [email protected]
EM-5671 Rev.6 P. 2 / 8
COMPONENT IDENTIFICATION
■
REAR VIEW
RS-485 Connector
Power / FG Terminals
Node Address Setting Rotary SW
Operating Mode Setting Rotary SW
Configurator Jack
RS-232-C
9-pin Connector
RUN Indicator LED
Specifications
■
OPERATING MODE
COLD JUNCTION
COMP. (T/C)
LINE NOISE
FREQUENCY
BURNOUT (T/C)
NONE
UP
DOWN
With
50/60 Hz
50 Hz
60 Hz
1
4
7
2
5
8
3
6
9
Without
50 Hz
60 Hz
A
D
B
E
C
F
Note 1: AD conversion rate is half as long as the line fre-
quency.
Note 2: Specifying the exact frequency (50 Hz and 60 Hz) pro-
vides better protection than 50/60 Hz setting.
Note 3: Factory default setting is ‘1.’
INSTALLATION
■
DIN RAIL MOUNTING
Set the body so that its DIN rail
adaptor is at the bottom. Pull
down the DIN rail adaptor.
Position the upper hook at the
rear side on the DIN rail and
push in the lower. Push back the
DIN rail adaptor.
■
WALL MOUNTING
Set the body so that its DIN rail
adaptor is at the bottom. Pull
down the DIN rail adaptor.
Refer to “EXTERNAL DIMENSIONS.”
TERMINAL CONNECTIONS
Connect the module referring to the connection diagram.
■
EXTERNAL DIMENSIONS unit: mm (inch)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 35
T1 T2 T3 T4
T5 T6 T7
104 (4.09)
10 (.39)
105 (4.13)
14 (.55
)
163 (6.42)
36–M3 I/O TERMINALS
165 (6.50)
175 (6.89)
3–5 (.20) dia.
MTG HOLES
FOR WALL MOUNT.
6.2 (.24)
15.5 (.61)
[6 (.24)]
40 (1.57)
3 (.12)
46 (1.81)
DIN RAIL
35 mm wide
DIN Rail Adaptor
DIN Rail
35mm wide