MB-08, MB-16
1) Install the MB onto a panel surface with the attached 2
pan-head screws (M5 × 40).
2) Remove the closing panels on which the Transducers are
to be mounted. Be sure to keep the gasket attached to the
closing panel so that it will be reused when attaching the
MB to the base socket.
For the P-UNIT Transducers, one unit requires a space
for two closing panels. Remove only the right closing
panel, seen from the front when the pressure supply con-
nections to the MB is positioned at the bottom.
3) Loosen the two screws (M3 × 16) attaching the Trans-
ducer body to its base socket to separate them.
4) Mount the base socket onto the MB with the two screws
(M4 × 20) provided with the Transducer. Be sure to in-
sert the gasket between them.
5) Attach the pressure supply pipe referring to ‘Piping.’
6) Plug the Transducer body into its base socket and fasten
the M3 screws which had been loosened in the above pro-
cedure (3).
Note 1: Put the closing panel back and the gasket onto the MB
if the base socket is not attached immediately.
Note 2: Remove the closing panels at the last moment before
mounting the base socket, in order to prevent any dust
entering into the MB.
Note 3: When installing an additional base socket to an al-
ready working MB, stop the air supply.
EXTERNAL DIMENSIONS
unit: mm (inch)
2–4.3 (.17) dia.
MTG HOLE
•
MB-01
75 (2.95)
approx.
27
(1.06)
10 (.39)
1/4” NPT FITTING
Rc 1/4
152 (5.98)
215 (8.46)
225 (8.86)
•
MB-08
178 (7.01)
418 (16.46)
428 (16.85)
2–3/8” NPT FITTING
2–Rc 3/8
4–6 (.24) dia.
MTG HOLE
3–R3/8 PLUG
3–R3/8 PLUG
CLOSING PANEL
14 (.55)
35 (1.38)
27 (1.06)
36 (1.42)
178 (7.01)
•
MB-16
75 (2.95)
approx
.
31
(1.22)
54 (2.13)
3/8” NPT FITTING
Rc 3/8
4–6 (.24) dia.
MTG HOLE
CLOSING PANEL
14 (.55)
35 (1.38)
27 (1.06)
36.5
(1.44)
75 (2.95
)
approx
.
31
(1.22)
54 (2.13)
13.5 (.53)
CLOSING PANEL
14 (.55)
35 (1.38)
27 (1.06)
25 (.97)
15 (.59)
2–5 (.20) dia. MTG HOLE
COUNTERBORE,
8 (.31) dia., 10 (.39)deep
•
MB-P1
75 (2.95)
approx
.
27
(1.06)
10 (.39
)
1/4” NPT FITTING
Rc 1/4
CLOSING PANEL
14 (.55)
35 (1.38)
27 (1.06)
50.5 (1.99)
40.4 (1.59)
MB
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: [email protected]