TN Systems (common earth)

TT Systems (independent earth)

N

Protected

device

G

Three-phase

/3-wire

(V connection)

Three-phase

/4-wire

(V connection)

L1

L2

L3

SPD2

POWER (e.g.)

SPD1

Three-phase/4-wire 220V AC

MAL-230x

SPD2

ACC

CNB2-5

POWER (e.g.)

SPD1

Three-phase/4-wire 220V AC

MAL-230x

SPD2

MALN-230

ACC

CNB2-7

ACC

SPD1 SPD1 SPD1

Protected

device

G

L1

L2

L3

ACC

SPD1 SPD1 SPD1

N

L1

L2

L3

*

1. Wiring only for three-phase/4-wire

Generator or transformer

Generator or transformer

POWER SYSTEM

Circuit

breaker

Circuit

breaker

 

*

1

 

*

1

MAL

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-8162  Rev.1  P. 6 / 8

Summary of Contents for MAL-230x

Page 1: ...device such as a lightning rod and low voltage electronics equipment are connect ed with equipotential bonding 2 In case the low voltage wiring is possible to be hit by the direct or almost direct li...

Page 2: ...ution board 10 m or more away from the low voltage inlet energy coordination is achieved FEATURES CURRENT CAPACITY The one port SPD can be used regardless of the load cur rent SAFETY AND HIGH DENSITY...

Page 3: ...CNB2 CIRCUIT CONNECTION DIAGRAM Thermal Breaker L N PE 1 2 Discharge Element ALARM OUTPUT Terminal block provided for the alarm output option Schematic shows the operation in normal conditions INSTALL...

Page 4: ...he data sheets of the class II surge protector for details 4 If the service entrance switchgear and switchgear or protective device wiring distance is more than 10 m install the class II surge protect...

Page 5: ...re star connection Protected device G L2 L1 L1 L2 L3 L3 N N SPD2 ACC SPD1 SPD1 Protected device SPD2 G L2 L1 L3 ACC SPD1 SPD1 POWER e g SPD1 MAL 400A Three phase 4 wire 220V AC MAL 230x SPD2 ACC CNB2...

Page 6: ...g SPD1 Three phase 4 wire 220V AC MAL 230x SPD2 MALN 230 ACC CNB2 7 ACC SPD1 SPD1 SPD1 Protected device G L1 L2 L3 ACC SPD1 SPD1 SPD1 N L1 L2 L3 1 Wiring only for three phase 4 wire Generator or trans...

Page 7: ...evice is recommended for ad equate protection Ground both the surge protector and the protected device to the same equipotentially bonding bar as following If the protected device has no ground termin...

Page 8: ...peri ence a strong lightning storm DO NOT attempt checking or replacing the surge protector during a thunder storm for safety Checking procedure is as explained below CUTTING OFF POWER SUPPLY Cut off...

Reviews: