INSTALLATION

Set the unit so that its DIN rail adapter is at the bottom.  When the unit is installed to an Installation Base (model M6SBS), 
refer to its instruction manual.

 

MOUNTING THE UNIT ON A DIN RAIL

A) Hang the upper hook at the rear side of unit on the DIN 

rail.

B) Push in the lower in keeping pressing the unit to the DIN 

rail.

A

DIN Rail

B

 

REMOVING THE UNIT

A) Pull down the DIN rail adaptor using a minus screwdriv-

er.

B) Pull out the lower part of the unit.
C) Remove the upper part from the DIN rail.

A

DIN Rail Adaptor

C

B

TERMINAL CONNECTIONS

Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit.

 

EXTERNAL DIMENSIONS  unit: mm (inch)

94 (3.70)

5.9 (.23)

DIN RAIL

35mm wide

DIN RAIL HOOK

*

Use a minus screwdriver: tip width 3.8 mm max., tip thickness 0.5 to 0.6 mm

102 (4.02)

[0.5 (.02)]

SCREWDRIVER

INSERTION ANGLE

  : approx. 40°

WIRE INSERTION ANGLE

: approx.35°

TEST PROBE

max. 2 (.08) dia.

SCREWDRIVER 

*

INSERTION ANGLE

       : approx. 35°

5

6

7

8

1

2

3

4

• When mounting, no extra space is needed between units.