background image

MODEL: M6DXAT

  Pollution Degree 2
  Max. operating voltage 250 V (relay output circuit)
  Input or power to output: Reinforced insulation
  Input to power: Basic insulation

EXTERNAL VIEW

(With the cover open)

Status Indicator LED

Configurator Jack

Power LED

Alarm Monitor LED

DIMENSIONS unit: mm (inch)

94 (3.70)

5.9 (.23)

DIN RAIL HOOK

102 (4.02)

[0.5 (.02)]

8–M3
EURO TERMINAL

DIN RAIL
35mm wide

5

6

7

8

1

2

3

4

• When mounting, no extra space is needed between units.

WIRE INSERTION ANGLE: approx. 7°

SCREWDRIVER
INSERTION ANGLE
: approx. 40°

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Summary of Contents for M6D Series

Page 1: ...types GENERAL SPECIFICATIONS Connection Input and output Euro terminal torque 0 3 N m Power input Via the Installation Base model M6DBS or Euro terminal torque 0 3 N m Applicable wire size 0 2 to 2 5...

Page 2: ...C 0 006 F of max span Response time 0 5 sec 0 100 at 90 setpoint Burnout response time 1 sec Line voltage effect 0 1 over voltage range Insulation resistance 100 M with 500 V DC Dielectric strength 20...

Page 3: ...k Power LED Alarm Monitor LED DIMENSIONS unit mm inch 94 3 70 5 9 23 DIN RAIL HOOK 102 4 02 0 5 02 8 M3 EURO TERMINAL DIN RAIL 35mm wide 5 6 7 8 1 2 3 4 When mounting no extra space is needed between...

Page 4: ...uctive Load Coil Diode Varistor or CR Circuit POWER OUTPUT Ry CONFIGURATOR JACK STATUS LED ALARM MONITOR LED Digital Computation T C comp leadwire CJC SENSOR CONNECTOR POWER POWER LED Specifications a...

Page 5: ...such that appropriate clearance and creepage distances are maintained to con form to CE requirements Failure to observe these re quirements may invalidate the CE conformance POWER INPUT RATING OPERATI...

Page 6: ...to the DIN rail REMOVING THE UNIT A Pull down the DIN rail adaptor using a minus screw driver B Pull out the lower part of the unit C Remove the upper part from the DIN rail DIN Rail A B DIN Rail Adap...

Page 7: ...L DIN RAIL 35mm wide 5 6 7 8 1 2 3 4 When mounting no extra space is needed between units WIRE INSERTION ANGLE approx 7 SCREWDRIVER INSERTION ANGLE approx 40 2 4 3 NC NO COM 5 6 OUTPUT POWER CONFIGURA...

Page 8: ...xplained below CALIBRATION Warm up the unit for at least 10 minutes H Setpoint Increase the input signal from a value lower than the set point and check that the relay trips at the H setpoint within t...