M5CTC

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-2486  Rev.4  P. 2 / 4

TERMINAL CONNECTIONS

Connect the unit as in the diagram below or refer to the connection diagram on the front of the unit.

 

EXTERNAL DIMENSIONS  unit: mm (inch)

94 (3.70)

3 (.12)

25 (.98)

41 (1.61)

[3.3 (.13)]

• When mounting, no extra space is needed between units.

DIN RAIL

35mm wide

8–M3.5 SCREW

7.3 (.29)

1 2

3 4

5 6

7 8

 

CLAMP-ON CURRENT SENSOR (leadwire type CLSA)

• 0 – 10A through 0 – 75A Use

Sensor model No.

: CLSA-08

Sensor cable model No.

: CLSA-08C-30

Applicable cable diameter

: Max. 10.0

Sensor leadwire

: AWG 22

Weight

: 45 g (1.6 oz)

L

K

 10 (.39)

dia.

41 (1.61)

23 (.91)

27 (1.05)

26 (1.02)

150 (5.91)

3000 (118)

l

k

• 0 – 100A Use

Sensor model No.

: CLSA-12

Sensor cable model No.

: CLSA-08C-30

Applicable cable diameter

: Max. 16.0

Sensor leadwire

: AWG 22

Weight

: 70 g (2.5 oz)

16 (.63)

dia.

44.5 (1.75)

29 (1.14)

30 (1.18)

31 (1.22)

150 (5.91)

l

k

L

K

3000 (118)

• 0 – 125A through 0 – 300A Use

Sensor model No.

: CLSA-30

Applicable cable diameter

: Max. 24.0

Sensor leadwire

: AWG 18, 200 mm

Weight

: 200 g (7.1 oz)

 24 (.94)

dia.

64 (2.52)

47.5 (1.87)

40 (1.57)

34 (1.34)

200 (7.87)

4
(.16)

4

(.16)

l

k

K

L

• 0 – 350A through 0 – 500A Use

Sensor model No.

: CLSA-50

Applicable cable diameter

: Max. 36.0

Sensor leadwire

: AWG 18, 200 mm

Weight

: 300 g (10.6 oz)

36 (1.41)

dia.

80 (3.15)

59.5 (2.34)

50 (1.97)

38 (1.50)

4
(.16)

4

(.16)

200 (7.87)

l

k

K

L

Summary of Contents for M5CTC

Page 1: ...o physical impact Environmental temperature must be within 5 to 55 C 23 to 131 F with relative humidity within 0 to 90 RH in order to ensure adequate life span and operation WIRING Do not install cables close to noise sources relay drive cable high frequency line etc Do not bind these cables together with those in which noises are present Do not install them in the same duct Install lightning surg...

Page 2: ...pplicable cable diameter Max 10 0 Sensor leadwire AWG 22 Weight 45 g 1 6 oz L K 10 39 dia 41 1 61 23 91 27 1 05 26 1 02 150 5 91 3000 118 l k 0 100A Use Sensor model No CLSA 12 Sensor cable model No CLSA 08C 30 Applicable cable diameter Max 16 0 Sensor leadwire AWG 22 Weight 70 g 2 5 oz 16 63 dia 44 5 1 75 29 1 14 30 1 18 31 1 22 150 5 91 l k L K 3000 118 0 125A through 0 300A Use Sensor model No ...

Page 3: ...g 7 1 oz k k l l 2 M3 SCREW 55 9 2 20 35 9 1 41 8 3 33 8 3 33 75 7 2 98 24 dia 94 TERMINAL COVER detachable K L 0 225A through 0 400A Use Sensor model No CLSB 40 Applicable cable diameter Max 35 0 Weight 300 g 10 6 oz 35 dia 1 38 k k l l 2 M3 SCREW K L 73 5 2 89 35 5 1 40 8 8 35 8 8 35 93 3 66 TERMINAL COVER detachable 0 500A through 0 600A Use Sensor model No CLSB 60 Applicable cable diameter Max...

Page 4: ...e output as explained in the following HOW TO CALIBRATE THE OUTPUT SIGNAL Use a signal source and measuring instruments of sufficient accuracy level Turn the power supply on and warm up for more than 10 minutes 1 ZERO Apply 10 input and adjust output to 10 2 SPAN Apply 100 input and adjust output to 100 3 Check ZERO adjustment again with 10 input 4 When ZERO value is changed repeat the above proce...

Reviews: