Functions & Features
• Converts pulse rate into convenient engineering unit for
display on a totalizing counter or meter
• Excitation
• Scaling factor adjustable of 1.0000 × 10

0

 to 0.0001 × 10

–6

• Various outputs (open collector, voltage pulse and AC/DC
switch)
• Three-way isolation
• CE marking
• UL approval

Typical Applications
• Positive displacement flowmeters and turbine flowmeters
• Magnetic tachometers

Model

23 (.91)

76

(2.99)

mm (inch)

124

(4.88)

MODEL: M2PRU–[1][2][3]–[4][5]

ORDERING INFORMATION

• Code number: M2PRU-[1][2][3]-[4][5]
Specify a code from below for each [1] through [5].
 (e.g. M2PRU-A24A-M2/CE/Q)
• Scaling factor (e.g. 0.7000 × 10

–2

)

• Specify the specification for option code /Q
  (e.g. /C01/S01)

[1] INPUT

A1: Open collector
A2: Mechanical contact
C: Voltage pulse (sensitivity 2 V)
H: Two-wire current pulse

[2] EXCITATION

4: 12 V DC / 30 mA
7: 24 V DC / 30 mA

[3] OUTPUT

A: Open collector (max. 100 kHz)
M: 5 V pulse (max. 100 kHz)
N: 12 V pulse (max. 100 kHz)
P: 24 V pulse  (max. 100 kHz)
R: AC/DC switch (max. 1 kHz)

[4] POWER INPUT

AC Power

M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
(90 – 264 V for UL)

DC Power

R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
R2: 11 – 27 V DC
(Operational voltage range 11 – 27 V, ripple 10 %p-p max.)
(Select ‘/N’ for ‘Standards & Approvals’ code.)
P: 110 V DC
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
(110 V ±10 % for UL)

[5] OPTIONS (multiple selections)

STANDARDS & APPROVALS (must be specified)

/N: Without CE or UL
/CE: CE marking
/UL: UL approval (CE marking)

OTHER OPTIONS

blank: none
/Q:  Option other than the above (specify the specification)
(UL not available)

SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)

/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating

TERMINAL SCREW MATERIAL

/S01: Stainless steel

CAUTION

1) The M2PRU’s output waveform is not uniform due to its
scaling method.  The user must be aware that it may be
inconvenient for certain types of application.
2) The M2PRU is designed to accept at the maximum of 100
kHz, which may cause errors due to chattering in the input
pulses.
A filter circuitry (time constant: approx. 1 msec.) is
incorporated to eliminate unwanted chattering when the
mechanical contact input is specified.  It is effective for

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Summary of Contents for M2PRU

Page 1: ...z 90 264 V for UL DC Power R 24 V DC Operational voltage range 24 V 10 ripple 10 p p max R2 11 27 V DC Operational voltage range 11 27 V ripple 10 p p max Select N for Standards Approvals code P 110 V...

Page 2: ...shortcircuit Open Collector Frequency range 0 100 kHz Pulse width time requirement Min 5 sec for ON and OFF Sensing Approx 24 V DC 2 mA Detecting levels 400 0 8 V for ON 1200 2 4 V for OFF Mechanical...

Page 3: ...t Reinforced insulation Approval UL C UL nonincendive Class I Division 2 Groups A B C and D hazardous locations ANSI ISA 12 12 01 CAN CSA C22 2 No 213 UL C UL general safety requirements UL 61010B 1 C...

Page 4: ...or Input Connection Examples PWR Voltage Pulse DC Coupled PWR Open Collector Output Connection Examples 9 12 9 12 Voltage Pulse 9 12 AC DC SWITCH SCALING FACTOR ADJ Scaler PULSE WIDTH ADJ 12k 24V 1 4...

Page 5: ...o observe these re quirements may invalidate the CE UL conformance POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicat...

Page 6: ...in the diagram below or refer to the connection diagram on the side of the unit OUTPUT 9 12 U V POWER 13 14 INPUT 1 5 4 SENSOR EXCITATION Mechanical Contact Open Collector Input Connection Examples PW...

Page 7: ...switches 10 1 through 10 n apply respectively to each digit of the decimals and exponential as shown below Output Rate Input Rate 0 A B C D 10 E where the scaling factor is adjustable from 1 0000 10...